ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
William M. Novick
Donald C. Watson
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gurbuz, A. T.
Right arrow Articles by Watson, D. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gurbuz, A. T.
Right arrow Articles by Watson, D. C.

Ann Thorac Surg 1998;65:1105-1109
© 1998 The Society of Thoracic Surgeons

Impact of Ultrafiltration on Blood Use for Atrial Septal Defect Closure in Infants and Children

A. Tayfun Gurbuz, MDaa, William M. Novick, MDaa, Connie A. Pierce, RNaa, Donald C. Watson, MDaa

a University of Tennessee–Memphis, Le Bonheur Children’s Medical Center, Memphis, Tennessee, USA

Address reprint requests to Dr Novick, Pediatric Cardiothoracic Surgery, The Heart Center, 777 Washington Ave, Suite 215, Memphis, TN 38105
e-mail: (ichfno{at}aol.com)

Presented at the Forty-fourth Annual Meeting of the Southern Thoracic Surgical Association, Naples, FL, Nov 6–8, 1997.

Background. Infants and children undergoing open cardiac operations have a high incidence of blood product transfusion. Ultrafiltration has been shown to reverse hemodilution and improve myocardial function and hemodynamics after cardiopulmonary bypass (CPB).

Methods. The effect of ultrafiltration on the amount of blood transfusion and hospital charge in 39 consecutive patients who underwent elective atrial septal defect repair was examined. Patients in group I (n = 26) had a conventional cardiopulmonary circuit prime with blood, whereas 13 patients had bloodless prime (group II). Ultrafiltration was used immediately after weaning from CPB in group II. The patients in group I received blood products after discontinuation of CPB to achieve a hematocrit of 30%. The amount of blood product used, hematocrit immediately after CPB and on arrival in intensive care unit, postoperative hemodynamics and saturations, total operating room charge, blood charge, hospital stay, and hospital charge were compared.

Results. Mean body weight (15.8 kg in group I versus 17.5 kg in group II) and preoperative hematocrit values (35.6% in group I versus 34.2% in group II) were similar. Mean hematocrit immediately after CPB was 22% and 14% in group I and II, respectively (p < 0.0001). The mean hematocrit upon arrival to the intensive care unit was 34% in group I and 22% in group II (p < 0.0001). The amount of blood product transfusion was 32 mL/kg in group I and 3 mL/kg in group II patients (p < 0.0001). The patients in group II had significantly less blood bank charges; however, operating room charges and total hospital charges were similar between the two groups.

Conclusions. Elective atrial septal defect repair was performed with no blood product transfusion without increased morbidity or hospital stay. Ultrafiltration can be used to reverse hemodilution resulting from a bloodless CPB prime without an increase in hospital charge.




This article has been cited by other articles:


Home page
Asian Cardiovasc. Thorac. Ann.Home page
S. G Raja, S. Yousufuddin, F. Rasool, A. Nubi, M. Danton, and J. Pollock
Impact of modified ultrafiltration on morbidity after pediatric cardiac surgery.
Asian Cardiovasc Thorac Ann, August 1, 2006; 14(4): 341 - 350.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. Ando, Y. Takahashi, and N. Suzuki
Open Heart Surgery for Small Children Without Homologous Blood Transfusion by Using Remote Pump Head System
Ann. Thorac. Surg., November 1, 2004; 78(5): 1717 - 1722.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
C. Mavroudis and R. M. Sade
The Southern Thoracic Surgical Association 50th anniversary celebration: the impact of STSA pediatric cardiothoracic surgery manuscripts on surgical practice
Ann. Thorac. Surg., November 1, 2003; 76(90050): S47 - 67.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
M. A Maluf
Modified ultrafiltration in surgical correction of congenital heart disease with cardiopulmonary bypass
Perfusion, January 1, 2003; 18(1_suppl): 61 - 68.
[Abstract] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
L. D. Thompson, D. B. McElhinney, P. Findlay, W. Miller-Hance, M. J. Chen, M. Minami, E. Petrossian, A. J. Parry, V. M. Reddy, and F. L. Hanley
A prospective randomized study comparing volume-standardized modified and conventional ultrafiltration in pediatric cardiac surgery
J. Thorac. Cardiovasc. Surg., August 1, 2001; 122(2): 220 - 228.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
R. G. Leyh, C. Bartels, E. Joubert-Hubner, J. F.M. Bechtel, and H. H. Sievers
Influence of modified ultrafiltration on coagulation, fibrinolysis and blood loss in adult cardiac surgery
Eur. J. Cardiothorac. Surg., February 1, 2001; 19(2): 145 - 151.
[Abstract] [Full Text] [PDF]


Home page
NeoReviewsHome page
P. D. Yorgin, A. Belson, and K. V. Lemley
Continuous Renal Replacement Therapy in Neonates and Young Infants
NeoReviews, September 1, 2000; 1(9): e163 - 172.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1998 by The Society of Thoracic Surgeons.