ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
José M. Bernal
José M. Revuelta
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bernal, J. M.
Right arrow Articles by Revuelta, J. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bernal, J. M.
Right arrow Articles by Revuelta, J. M.

Ann Thorac Surg 1998;65:137-143
© 1998 The Society of Thoracic Surgeons


Original Articles: Cardiovascular

The CarboMedics Valve: Experience With 1,049 Implants

José M. Bernal, MD, José M. Rabasa, MD, Francisco Gutierrez-Garcia, MD, Carlos Morales, MD, J. Francisco Nistal, MD, José M. Revuelta, MD

Department of Cardiovascular Surgery, Hospital Universitario Valdecilla, Universidad de Cantabria, Santander, Spain

Accepted for publication August 25, 1997.

Dr Bernal, Cirugía Cardiovascular, Hospital Universitario Valdecilla, 39008-Santander, Spain.

Background. The lack of valve rotatability, the structural deterioration, and the rate of valve-related complications with the standard mechanical bileaflet prosthesis led to the development of a new second-generation bileaflet valve in 1986.

Methods. Between January 1989 and March 1994, 1,049 CarboMedics valves were implanted in 859 patients. The rotatability was used in 109 mitral prostheses (21.5%) and in 61 aortic prostheses (11.6%). Follow-up was 97.1% complete, with 3,049 patient-years.

Results. The hospital mortality was 6.9% for the mitral group, 3.4% for the aortic group, and 10.7% for the double-valve group (p < 0.005). The actuarial survival curve at 5 years was 77.3% ± 3.6%, 90.1% ± 2.5%, and 79.2% ± 3.7% (p = 0.0003), freedom from thromboembolism was 89.1% ± 3.6%, 87.1% ± 3.8%, and 68.8% ± 8.2%, freedom from reoperation was 95.9% ± 1.4%, 98.9% ± 0.6%, and 94.9% ± 2.4%, and freedom from valve-related complications was 68.8% ± 4.1%, 79.5% ± 3.5%, and 55.3% ± 5.9% after mitral, aortic, and mitral and aortic valve replacement, respectively. There were five episodes of valve thrombosis, but no structural deterioration occurred.

Conclusions. The clinical performance of the CarboMedics valve is quite satisfactory, with a low incidence of valve-related mortality and morbidity. The rotatability feature was useful when the native valve was preserved or for repeat valve replacement.




This article has been cited by other articles:


Home page
Card Surg AdultHome page
N. D. Desai and G. T. Christakis
Bioprosthetic Aortic Valve Replacement: Stented Pericardial and Porcine Valves
Card. Surg. Adult, January 1, 2008; 3(2008): 857 - 894.
[Full Text]


Home page
ICVTSHome page
J.-P. Verhoye, I. Abouliatim, B. Lelong, A. Ingels, X. Roques, J. Pierre Villemot, T. Langanay, and A. Leguerrier
Edwards Mira bileaflet prosthesis in aortic position: midterm results of a prospective multi-centre study
Interactive CardioVascular and Thoracic Surgery, August 1, 2007; 6(4): 458 - 461.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
R. Haaverstad, N. Vitale, A. Karevold, G. Cappabianca, A. Tromsdal, P. S. Olsen, L. Kober, H. Ihlen, K. A. Rein, and J. L Svennevig
Clinical and echocardiographic assessment of the Medtronic Advantage aortic valve prosthesis: the Scandinavian multicentre, prospective study
Heart, April 1, 2007; 93(4): 500 - 505.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
D. Baykut, L. Grize, C. Schindler, A. S. Keil, F. Bernet, and H.-R. Zerkowski
Eleven-year single-center experience with the ATS Open Pivot Bileaflet heart valve.
Ann. Thorac. Surg., September 1, 2006; 82(3): 847 - 852.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
A. Kulik, F. D. Rubens, P. S. Wells, C. Kearon, T. G. Mesana, J. van Berkom, and B.-K. Lam
Early Postoperative Anticoagulation After Mechanical Valve Replacement: A Systematic Review
Ann. Thorac. Surg., February 1, 2006; 81(2): 770 - 781.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
J. M. Bernal, J. Lorca, D. Prieto-Salceda, I. Pulitani, A. Ponton, I. Garcia, and J. M. Revuelta
Performance at 10 years of the CarboMedics 'Top-Hat' valve. Postclamping time is a predictor of mortality
Eur. J. Cardiothorac. Surg., February 1, 2006; 29(2): 144 - 149.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
C. Stefanidis, A. M. Nana, D. De Canniere, M. Antoine, J.-L. Jansens, C.-H. Huynh, and J.-L. Le Clerc
10-Year Experience With the ATS Mechanical Valve in the Mitral Position
Ann. Thorac. Surg., June 1, 2005; 79(6): 1934 - 1938.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
C. H. Kang, H. Ahn, K. H. Kim, and K.-B. Kim
Long-Term Result of 1144 CarboMedics Mechanical Valve Implantations
Ann. Thorac. Surg., June 1, 2005; 79(6): 1939 - 1944.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
R. Tominaga, K. Kurisu, Y. Ochiai, Y. Tomita, M. Masuda, S. Morita, and H. Yasui
A 10-Year Experience With the Carbomedics Cardiac Prosthesis
Ann. Thorac. Surg., March 1, 2005; 79(3): 784 - 789.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. M. Bernal, J. Gutierrez-Morlote, J. Llorca, J. M. San Jose, D. Morales, and J. M. Revuelta
Tricuspid Valve Repair: An Old Disease, a Modern Experience
Ann. Thorac. Surg., December 1, 2004; 78(6): 2069 - 2074.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
N. Vitale, G. Cappabianca, G. Visicchio, C. Fondacone, V. Paradiso, G. Mannatrizio, and L. d. L. T. Schinosa
Midterm evaluation of the Sorin Bicarbon heart valve prosthesis: single-center experience
Ann. Thorac. Surg., February 1, 2004; 77(2): 527 - 531.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
A. M. Gillinov, E. H. Blackstone, J. M. Alster, J. M. Craver, W. A. Baumgartner, S. A. Brewster, L. H. Kleinman, and N. G. Smedira
The Carbomedics Top Hat supraannular aortic valve: a multicenter study
Ann. Thorac. Surg., April 1, 2003; 75(4): 1175 - 1180.
[Abstract] [Full Text] [PDF]


Home page
ICVTSHome page
J.P. Remadi, P. Marticho, A. Nzomvuama, and A. Degandt
Preliminary results of 130 aortic valve replacements with a new mechanical bileaflet prosthesis: the Edwards MIRA valve
Interactive CardioVascular and Thoracic Surgery, March 1, 2003; 2(1): 80 - 83.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
R. W. Emery, G. J. Van Nooten, and P. J. Tesar
The initial experience with the ATS Medical mechanical cardiac valve prosthesis
Ann. Thorac. Surg., February 1, 2003; 75(2): 444 - 452.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
G. L. Grunkemeier and Y. Wu
"Our complication rates are lower than theirs": Statistical critique of heart valve comparisons
J. Thorac. Cardiovasc. Surg., February 1, 2003; 125(2): 290 - 300.
[Abstract] [Full Text] [PDF]


Home page
Card Surg AdultHome page
N. D. Desai and G. T. Christakis
Stented Mechanical/Bioprosthetic Aortic Valve Replacement
Card. Surg. Adult, January 1, 2003; 2(2003): 825 - 856.
[Full Text]


Home page
Ann. Thorac. Surg.Home page
Y. Soga, H. Okabayashi, T. Nishina, S. Enomoto, I. Shimada, T.-A. Miyamoto, and T. Ban
Up to 8-year follow-up of valve replacement with CarboMedics valve
Ann. Thorac. Surg., February 1, 2002; 73(2): 474 - 479.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
P. P. Urbanski, M. Wagner, M. Zacher, and R. W. Hacker
Aortic root replacement versus aortic valve replacement: a case-match study
Ann. Thorac. Surg., July 1, 2001; 72(1): 28 - 32.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. Carrier, M. Pellerin, L. P. Perrault, P. Page, Y. Hebert, R. Cartier, I. Dyrda, and L. C. Pelletier
Aortic valve replacement with mechanical and biologic prostheses in middle-aged patients
Ann. Thorac. Surg., May 1, 2001; 71 (2007): S253 - S256.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
S. John, E. Ravikumar, C. N. John, and V. V. Bashi
25-year experience with 456 combined mitral and aortic valve replacement for rheumatic heart disease
Ann. Thorac. Surg., April 1, 2000; 69(4): 1167 - 1172.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. J.R. Dalrymple-Hay, R. Pearce, S. Dawkins, M. P. Haw, R. K. Lamb, S. A. Livesey, and J. L. Monro
A single-center experience with 1,378 CarboMedics mechanical valve implants
Ann. Thorac. Surg., February 1, 2000; 69(2): 457 - 463.
[Abstract] [Full Text] [PDF]


Home page
Med Decis MakingHome page
E. W. Steyerberg, M. Kallewaard, Y. Van Der Graaf, L. A. Van Herwerden, and J.D. F. Habbema
Decision Analyses for Prophylactic Replacement of the Bjork-Shiley Convexo-concave Heart Valve:: An Evaluation of Assumptions and Estimates
Med Decis Making, January 1, 2000; 20(1): 20 - 32.
[Abstract] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
W.R. E. Jamieson, R. T. Miyagishima, G. L. Grunkemeier, E. Germann, C. Henderson, G. J. Fradet, L. H. Burr, and S. V. Lichtenstein
Bileaflet mechanical prostheses performance in mitral position
Eur. J. Cardiothorac. Surg., June 1, 1999; 15(6): 786 - 794.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. M. Bernal, R. Martin-Duran, J. M. Rabasa, and J. M. Revuelta
The CarboMedics ""Top-Hat"" supraannular prosthesis
Ann. Thorac. Surg., May 1, 1999; 67(5): 1299 - 1303.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1998 by The Society of Thoracic Surgeons.