Ann Thorac Surg 1997;64:1678-1680
© 1997 The Society of Thoracic Surgeons
Department of Thoracic and Cardiovascular Surgery, Sapporo Medical University School of Medicine, Sapporo, Japan
Accepted for publication May 8, 1997.
Background. The insertion of bioprosthetic valves into the pulmonic position is not performed commonly because of uncertainty concerning the necessity and durability of such valves.
Methods. We reviewed the long-term outcome of 10 patients who underwent pulmonary valve replacement with bioprostheses between March 1985 and March 1997. A Carpentier-Edwards supraannular bioprosthesis was used in 7 patients, a Hancock II bioprosthesis was used in 2 patients, and a Carpentier-Edwards pericardial bioprosthesis was used in 1 patient. The mean patient age at the time of pulmonary valve replacement was 38.9 ± 16.3 years (range, 15 to 63 years). The diagnoses were pulmonary valvular regurgitation after corrective surgery for tetralogy of Fallot in 7 patients, right ventricular outflow tract stenosis and absent right pulmonary artery combined with a double-outlet right ventricle in 1 patient, pulmonary valvular regurgitation with pulmonary artery dilatation in 1 patient, and aortic valve stenosis treated with our modification of the Ross procedure using a pulmonary bioprosthesis in 1 patient. Survivors were followed up for a mean of 5 years and 5 months.
Results. One patient underwent reoperation because of infective endocarditis of the bioprosthesis. No bioprosthetic valve dysfunction has been observed on Doppler echocardiography during a maximum follow-up period of 12.2 years, except in the patient who underwent replacement at 15 years of age.
Conclusions. Bioprostheses in the pulmonic position are durable in adult patients because they face a minimal hemodynamic load, but they may undergo early leaflet degeneration in younger patients.
Related Article
Ann. Thorac. Surg. 1997 64: 1680-1681.
This article has been cited by other articles:
![]() |
T. W. Waterbolk, E. S. Hoendermis, I. J. den Hamer, and T. Ebels Pulmonary valve replacement with a mechanical prosthesis. Promising results of 28 procedures in patients with congenital heart disease. Eur. J. Cardiothorac. Surg., July 1, 2006; 30(1): 28 - 32. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. S. Hartz, S. Y. Deleon, J. Lane, J. Dorotan, J. Joyce, E. Urbina, N. Ross-Ascuitto, and R. Ascuitto Medtronic freestyle valves in right ventricular outflow tract reconstruction Ann. Thorac. Surg., December 1, 2003; 76(6): 1896 - 1900. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. A. Vricella, M. A. Coady, and M. D. Black Initial experience with a stentless porcine bioprosthesis for right ventricular outflow tract reconstruction in children J. Thorac. Cardiovasc. Surg., March 1, 2003; 125(3): 727 - 728. [Full Text] [PDF] |
||||
![]() |
V. Rao, M. Kadletz, L. K. Hornberger, R. M. Freedom, and M. D. Black Preservation of the pulmonary valve complex in tetralogy of Fallot: how small is too small? Ann. Thorac. Surg., January 1, 2000; 69(1): 176 - 179. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Roth, O. T. Reuthebuch, W.-P. Klovekorn, and E. P. Bauer Repair of an aneurysm of the pulmonary trunk in a 65-year-old patient Ann. Thorac. Surg., January 1, 1999; 67(1): 244 - 246. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Morishita, T. Abe, J. Fukada, H. Sato, and C. Shiiku Alternative to reconstruction of the pulmonary outflow tract in the ross procedure Ann. Thorac. Surg., August 1, 1998; 66(2): 549 - 550. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |