ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Wolfgang Konertz
Holger Hotz
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Konertz, W.
Right arrow Articles by Reul, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Konertz, W.
Right arrow Articles by Reul, H.
Related Collections
Right arrowRelated Article

Ann Thorac Surg 1997;63:1138-1144
© 1997 The Society of Thoracic Surgeons


Original Article: Cardiovascular

Clinical Experience With the MEDOS HIA-VAD System in Infants and Children: A Preliminary Report

Wolfgang Konertz, MD, PhD, Holger Hotz, MD, Martin Schneider, MD, Mathias Redlin, MD, Helmut Reul, PhD

Departments of Cardiac Surgery, Anesthesiology, and Pediatric Cardiology, Charité, Humboldt-University Berlin, Berlin, and Helmholtz Institute, Aachen, Germany

Accepted for publication November 1, 1996.

Background. The need of pediatric cardiac assist is growing because of the complexity of the congenital conditions operated on and the increasing number of pediatric transplantations. We evaluated the newly developed pediatric MEDOS HIA-VAD ventricular assist device.

Methods. The pneumatic paracorporeal ventricular assist device has three left ventricular sizes (10-, 25-, and 60-mL maximum stroke volume) and three right ventricular sizes (9, 22.5, and 54 mL) and can be operated effectively with up to 180 cycles/min. We used this device in 6 consecutive pediatric patients. Intention of treatment was to bridge to transplantation in 3 patients and to aid in recovery from a cardiac operation in 3. Age ranged from 5 days to 8 years.

Results. Two children died during assist, 2 were weaned from the system and discharged home, and 2 had successful transplantation. During assist, laboratory variables indicative of impaired renal, hepatic, or pulmonary function normalized or showed a trend toward normalization. Both deaths were related to infection.

Conclusions. With the new MEDOS HIA-VAD ventricular assist device system, pediatric mechanical cardiac assist can be performed successfully. It requires timely implantation, careful monitoring, and adequate size-matched devices.


Related Article

Invited Commentary
Pedro J. del Nido
Ann. Thorac. Surg. 1997 63: 1144. [Extract] [Full Text]



This article has been cited by other articles:


Home page
ICVTSHome page
K. Januszewska, E. Malec, J. Birnbaum, M. Loeff, R. Sodian, C. Schmitz, H. Netz, and B. Reichart
Ventricular assist device as a bridge to heart transplantation in children
Interactive CardioVascular and Thoracic Surgery, November 1, 2009; 9(5): 807 - 810.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. Imamura, A. M. Dossey, P. Prodhan, M. Schmitz, E. Frazier, U. Dyamenahalli, A. Bhutta, W. R. Morrow, and R. D.B. Jaquiss
Bridge to Cardiac Transplant in Children: Berlin Heart versus Extracorporeal Membrane Oxygenation.
Ann. Thorac. Surg., June 1, 2009; 87(6): 1894 - 1901.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
R. Hetzer, E. V. Potapov, B. Stiller, Y. Weng, M. Hubler, J. Lemmer, V. Alexi-Meskishvili, M. Redlin, F. Merkle, F. Kaufmann, et al.
Improvement in survival after mechanical circulatory support with pneumatic pulsatile ventricular assist devices in pediatric patients.
Ann. Thorac. Surg., September 1, 2006; 82(3): 917 - 924.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
A.-M. McMahon, C. van Doorn, M. Burch, P. Whitmore, S. Neligan, P. Rees, R. Radley-Smith, A. Goldman, K. Brown, G. Cohen, et al.
Improved early outcome for end-stage dilated cardiomyopathy in children
J. Thorac. Cardiovasc. Surg., January 1, 2004; 126(6): 1781 - 1787.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
B. W. Duncan
Mechanical circulatory support for infants and children with cardiac disease
Ann. Thorac. Surg., May 1, 2002; 73(5): 1670 - 1677.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
B. W. Duncan, D. J. Bohn, A. M. Atz, J. W. French, P. C. Laussen, and D. L. Wessel
Mechanical circulatory support for the treatment of children with acute fulminant myocarditis
J. Thorac. Cardiovasc. Surg., September 1, 2001; 122(3): 440 - 448.
[Abstract] [Full Text] [PDF]


Home page
SEMIN CARDIOTHORAC VASC ANESTHHome page
A. Y. Schure, P. C. Laussen, and F. X. McGowan JR
Mechanical Cardiopulmonary Support of Infants and Children With Congenital Heart Disease
Seminars in Cardiothoracic and Vascular Anesthesia, March 1, 2001; 5(1): 46 - 54.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. A. Acker
Mechanical circulatory support for patients with acute-fulminant myocarditis
Ann. Thorac. Surg., March 1, 2001; 71 (2007): S73 - S76.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. P. Jacobs, J. W. Ojito, T. W. McConaghey, B. D. Boden, A. C. Chang, A. Aldousany, E. M. Zahn, and R. P. Burke
Rapid cardiopulmonary support for children with complex congenital heart disease
Ann. Thorac. Surg., September 1, 2000; 70(3): 742 - 750.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
S. Thuaudet
The Medos ventricular assist device system
Perfusion, July 1, 2000; 15(4): 337 - 343.
[PDF]


Home page
Ann. Thorac. Surg.Home page
C. Schmitz, A. Welz, O. Dewald, R. Kozlik-Feldmann, H. Netz, and B. Reichart
Switch from a BIVAD to a LVAD in a boy with Kawasaki disease
Ann. Thorac. Surg., April 1, 2000; 69(4): 1270 - 1271.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
B Stiller, I Dahnert, Y G Weng, E Hennig, R Hetzer, and P E Lange
Children may survive severe myocarditis with prolonged use of biventricular assist devices
Heart, August 1, 1999; 82(2): 237 - 240.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
R. Hetzer, M. Loebe, E. V. Potapov, Y. Weng, B. Stiller, E. Hennig, V. Alexi-Meskishvili, and P. E. Lange
Circulatory support with pneumatic paracorporeal ventricular assist device in infants and children
Ann. Thorac. Surg., November 1, 1998; 66(5): 1498 - 1506.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
S. Westaby, T. Katsumata, R. Houel, R. Evans, D. Pigott, O. H. Frazier, and R. Jarvik
Jarvik 2000 Heart : Potential for Bridge to Myocyte Recovery
Circulation, October 13, 1998; 98(15): 1568 - 1574.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
D. Shum-Tim, B. W. Duncan, V. Hraska, I. Friehs, T. Shin'oka, and R. A. Jonas
Evaluation of a Pulsatile Pediatric Ventricular Assist Device in an Acute Right Heart Failure Model
Ann. Thorac. Surg., November 1, 1997; 64(5): 1374 - 1380.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1997 by The Society of Thoracic Surgeons.