Ann Thorac Surg 1997;63:248-249
© 1997 The Society of Thoracic Surgeons
Divisions of Cardiology, Cardiac Surgery, and Neonatology, Hospital Infantil La Paz, Madrid, Spain
Accepted for publication July 5, 1996.
A newborn baby with complex congenital heart disease had severe persistent pericardial effusion after a systemic-pulmonary shunt. Pericardiocentesis and pericardiotomy could not stop pericardial leakage. At reoperation, topical application of a fibrin glue resulted in resolution of the leak and avoided replacement of the graft.
Related Article
Ann. Thorac. Surg. 1997 63: 250.