Ann Thorac Surg 1997;63:242-244
© 1997 The Society of Thoracic Surgeons
Division of Thoracic, Cardiac, and Vascular Surgery, Department of Surgery, and Department of Anesthesiology, Eberhard-Karls-University, Tuebingen, Germany
Accepted for publication August 7, 1996.
We report a case of severe anaphylactic shock during a cardiac operation that occurred as a consequence of aprotinin readministration in the presence of preformed aprotinin-specific antibodies. Both immunoglobulin G (3 hours) and immunoglobulin E (5 minutes) antibody levels dropped early after the clinical event. Despite their possibly limited clinical significance, we still recommend the conductance of specific antibody screening tests before readministration of aprotinin.
This article has been cited by other articles:
![]() |
R. J. Thoms and S. E. Marwin The Role of Fibrin Sealants in Orthopaedic Surgery J. Am. Acad. Orthop. Surg., December 1, 2009; 17(12): 727 - 736. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. Beierlein, A. M. Scheule, W. Dietrich, and G. Ziemer Forty Years of Clinical Aprotinin Use: A Review of 124 Hypersensitivity Reactions Ann. Thorac. Surg., February 1, 2005; 79(2): 741 - 748. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. M. Mahdy and N. R. Webster Perioperative systemic haemostatic agents Br. J. Anaesth., December 1, 2004; 93(6): 842 - 858. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. M. Scheule, W. Beierlein, S. Arnold, F. S. Eckstein, J. M. Albes, and G. Ziemer The Significance of Preformed Aprotinin-Specific Antibodies in Cardiosurgical Patients Anesth. Analg., February 1, 2000; 90(2): 262 - 262. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. M. Scheule, W. Beierlein, H. P. Wendel, M. J. Jurmann, F. S. Eckstein, and G. Ziemer APROTININ IN FIBRIN TISSUE ADHESIVES INDUCES SPECIFIC ANTIBODY RESPONSE AND INCREASES ANTIBODY RESPONSE OF HIGH-DOSE INTRAVENOUS APPLICATION J. Thorac. Cardiovasc. Surg., August 1, 1999; 118(2): 348 - 353. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Miyashita, Y. Hayashi, Y. Ohnishi, and M. Kuro Retrospective analysis of effect of low-dose aprotinin priming on allogeneic blood transfusion in repeated cardiac operations Perfusion, May 1, 1999; 14(3): 189 - 194. [Abstract] [PDF] |
||||
![]() |
W. Dietrich Incidence of Hypersensitivity Reactions Ann. Thorac. Surg., June 1, 1998; 65(90060): S60 - 64. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. M. Scheule, W. Beierlein, H. P. Wendel, F. S. Eckstein, M. K. Heinemann, and G. Ziemer Fibrin sealant, aprotinin, and immune response in children undergoing operations for congenital heart disease J. Thorac. Cardiovasc. Surg., April 1, 1998; 115(4): 883 - 889. [Abstract] [Full Text] [PDF] |
||||