ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lee, T.-M.
Right arrow Articles by Chu, S.-H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lee, T.-M.
Right arrow Articles by Chu, S.-H.
Related Collections
Right arrowRelated Article

Ann Thorac Surg 1996;62:1790-1795
© 1996 The Society of Thoracic Surgeons


Original Articles: Cardiovascular

Left Atrial Spontaneous Echo Contrast in Asymptomatic Patients With a Mechanical Valve Prosthesis

Tsung-Ming Lee, MD, Nai-Kuan Chou, MD, Sheng-Fang Su, PhD, Yueh-Juh Lin, MD, Ming-Fong Chen, MD, Chiau-Suong Liau, MD, Yuan-Teh Lee, MD, Shu-Hsun Chu, MD

Departments of Internal Medicine and Surgery, Cardiology Section, Center for Cardiovascular Research, College of Medicine, National Taiwan University, National Taiwan University Hospital, Taipei, and College of Medicine, National Cheng Kung University, Tainan, Taiwan

Accepted for publication June 26, 1996.

Background. Valve thromboembolism may be a fatal complication of mechanical valve prosthesis if detected late. Spontaneous echo contrast (SEC) is a well-documented prothrombotic phenomenon; here we report it in asymptomatic patients with a mechanical valve prosthesis.

Methods. Ninety-two asymptomatic patients with a mechanical valve prosthesis for underlying rheumatic heart disease underwent transesophageal echocardiography. Appendage area, peak filling and emptying velocities of the left atrial appendage, and the presence or absence of SEC and thrombi were determined. The results of 56 patients without SEC or thrombi (group I) were compared with those of 24 patients with SEC and no thrombi (group II) and 12 patients with thrombi (group III).

Results. Spontaneous echo contrast was present in 39% of the asymptomatic patients with a mechanical valve prosthesis. Although 12 patients had cardiac thrombi, including valve thrombi in 4, no patients presented symptoms. Anticoagulant therapy had no significant association with SEC and atrial thrombi. There was a significantly greater prevalence of atrial fibrillation and mitral prosthesis in groups II and III than in group I. Two patterns of left atrial appendage flow were identified: one was organized biphasic flow with peak filling velocities of 41.2 ± 17.2 cm/s and emptying velocities of 40.5 ± 17.5 cm/s. The other showed irregular, very low peak filling velocities (10.4 ± 11.5 cm/s) and emptying velocities (12.3 ± 13.1 cm/s). The former flow pattern was associated with sinus rhythm and the latter form was associated with atrial fibrillation.

Conclusions. There was a relatively high prevalence of SEC and thrombi in patients with a mechanical valve prosthesis. Patients with a valve prosthesis may not have clinical symptoms. Anticoagulation intensity was not associated with the occurrence of SEC and thrombi. Patients with a mitral valve prosthesis and atrial fibrillation were identified as a high-risk of subgroup for the development of SEC and thrombi.


Related Article

Invited Commentary
Philip R. Liebson
Ann. Thorac. Surg. 1996 62: 1795. [Extract] [Full Text]



This article has been cited by other articles:


Home page
ChestHome page
E. Donal, H. Yamada, C. Leclercq, and D. Herpin
The Left Atrial Appendage, a Small, Blind-Ended Structure: A Review of Its Echocardiographic Evaluation and Its Clinical Role
Chest, September 1, 2005; 128(3): 1853 - 1862.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
S. Sadanandan and M. V. Sherrid
Clinical and echocardiographic characteristics of left atrial spontaneous echo contrast in sinus rhythm
J. Am. Coll. Cardiol., June 1, 2000; 35(7): 1932 - 1938.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
S. Benussi, C. Pappone, S. Nascimbene, G. Oreto, A. Caldarola, P. L. Stefano, V. Casati, and O. Alfieri
A simple way to treat chronic atrial fibrillation during mitral valve surgery: the epicardial radiofrequency approach
Eur. J. Cardiothorac. Surg., May 1, 2000; 17(5): 524 - 529.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
Y. Agmon, B. K. Khandheria, F. Gentile, and J. B. Seward
Echocardiographic assessment of the left atrial appendage
J. Am. Coll. Cardiol., December 1, 1999; 34(7): 1867 - 1877.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
T. O. Cheng, T.-M. Lee, and S.-H. Chu
Spontaneous Echo Contrast in Mechanical Valve Prosthesis
Ann. Thorac. Surg., June 1, 1997; 63(6): 1826 - 1827.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1996 by The Society of Thoracic Surgeons.