ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Michael C. Mauney
Curtis G. Tribble
Irving L. Kron
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Buchanan, S. A.
Right arrow Articles by Kron, I. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Buchanan, S. A.
Right arrow Articles by Kron, I. L.

Ann Thorac Surg 1996;62:1617-1621
© 1996 The Society of Thoracic Surgeons


Original Articles: General Thoracic

Intratracheal Surfactant Administration Preserves Airway Compliance During Lung Reperfusion

Scott A. Buchanan, MD, Michael C. Mauney, MD, Vikas I. Parekh, BS, Nuno F. DeLima, MD, Oliver A. R. Binns, MD, Jeffrey T. Cope, MD, Kimberly S. Shockey, MS, Curtis G. Tribble, MD, Irving L. Kron, MD

Thoracic and Cardiovascular Research Laboratory, Department of Surgery, University of Virginia Health Sciences Center, Charlottesville, Virginia

Accepted for publication June 27, 1996.

Background. Decreased airway compliance after lung transplantation has been observed with severe ischemia-reperfusion injury. Further, it has been shown that the surfactant system is impaired after lung preservation and reperfusion. We hypothesized that surfactant replacement after allograft storage could preserve airway compliance during reperfusion.

Methods. Rabbit lungs were harvested after flush with 50 mL/kg of cold saline solution. Immediate control lungs were studied with an isolated ventilation/perfusion apparatus using venous rabbit blood recirculated at 40 mL/min, room-air ventilation at 20 breaths/min, and constant airway pressure (n = 8). Twenty-four–hour control lungs were preserved at 4°C for 24 hours and then similarly studied (n = 7). Surfactant lungs underwent similar harvest and preservation for 24 hours, but received 1.5 mL/kg of intratracheal surfactant 5 minutes before reperfusion (n = 10). Airway pressure and flow were recorded continuously during 30 minutes of reperfusion. Tidal volume and airway compliance were calculated at 30 minutes.

Results. Tidal volume was 33.67 ± 0.57, 15.75 ± 5.72, and 29.83 ± 1.07 mL in the immediate control, 24-hour control, and surfactant groups, respectively (p = 0.004, surfactant versus 24-hour control). Airway compliance was 1.94 ± 0.27, 0.70 ± 0.09, and 1.46 ± 0.10 mL/mm Hg in the immediate control, 24-hour control, and surfactant groups, respectively (p = 0.002, surfactant versus 24-hour control).

Conclusions. We conclude that surfactant administration before reperfusion after 24 hours of cold storage preserves tidal volume and airway compliance in the isolated ventilated/perfused rabbit model of lung reperfusion injury.




This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
M. de Perrot, M. Liu, T. K. Waddell, and S. Keshavjee
Ischemia-Reperfusion-induced Lung Injury
Am. J. Respir. Crit. Care Med., February 15, 2003; 167(4): 490 - 511.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
S. N. Ghadiali, J. Banks, and J. D. Swarts
Effect of surface tension and surfactant administration on Eustachian tube mechanics
J Appl Physiol, September 1, 2002; 93(3): 1007 - 1014.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. A. Mathias, C. G. Tribble, J. F. Dietz, R. P. Nguyen, K. S. Shockey, J. A. Kern, and I. L. Kron
Aprotinin improves pulmonary function during reperfusion in an isolated lung model
Ann. Thorac. Surg., November 1, 2000; 70(5): 1671 - 1674.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
H. Itano, M. Aoe, S. Ichiba, M. Yamashita, H. Date, A. Andou, and N. Shimizu
Partial liquid ventilation for acute allograft dysfunction after canine lung transplantation
Ann. Thorac. Surg., February 1, 1999; 67(2): 332 - 339.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1996 by The Society of Thoracic Surgeons.