ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
John R. Liddicoat
Doff B. McElhinney
Frank L. Hanley
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Reddy, V. M.
Right arrow Articles by Hanley, F. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Reddy, V. M.
Right arrow Articles by Hanley, F. L.

Ann Thorac Surg 1996;62:393-400
© 1996 The Society of Thoracic Surgeons


Original Articles: Cardiovascular

Fetal Cardiac Bypass Using an In-Line Axial Flow Pump to Minimize Extracorporeal Surface and Avoid Priming Volume

V. Mohan Reddy, MD, John R. Liddicoat, MD, Judith R. Klein, MD, Doff B. McElhinney, MS, Richard K. Wampler, MD, Frank L. Hanley, MD

Division of Cardiothoracic Surgery, University of California, San Francisco, San Francisco, California

Background. Progressive metabolic acidosis, hypoxia, and hypercarbia develop rapidly after fetal cardiac bypass mainly as a result of an increase in placental vascular resistance and a decrease in placental blood flow. A number of factors including fetal stress, priming substances, and extracorporeal surfaces have been identified as possible stimuli causing this placental dysfunction. The purpose of this study was to examine the effects of avoiding priming volume and minimizing extracorporeal surface area on placental hemodynamics and function.

Methods. Fetal sheep (n = 16) at 118 to 122 days of gestation were subjected to cardiac bypass for 30 minutes using either an in-line axial-flow pump (Hemopump group: n = 8, no prime) or a roller pump with a venous reservoir (control group: n = 8, priming volume = 150 mL). After bypass, the fetuses were observed for 90 minutes. Placental blood flow and combined ventricular output were continuously measured with ultrasonic flow probes, and fetal blood gases were measured at specific intervals.

Results. Three fetuses in the control group died during the study, whereas all 8 fetuses in the Hemopump group remained in stable condition throughout the study period. During and after bypass, placental blood flow was significantly higher (p < 0.0001) and placental vascular resistance was significantly lower (p < 0.0001) in the Hemopump group than in the control group. Arterial pH and partial pressure of arterial oxygen declined significantly less (p < 0.0001), and partial pressure of arterial carbon dioxide increased significantly less (p = 0.0002) in the Hemopump group than in the control group.

Conclusions. Reducing the extracorporeal surface area and avoiding external priming substances preserves placental hemodynamics after fetal cardiac bypass. An in-line axial-flow pump is useful in miniaturizing the bypass circuits for potential use in fetal cardiac surgery.




This article has been cited by other articles:


Home page
PerfusionHome page
J. Lombardi, J. Sedgwick, J. Schenbeck, W. Lubbers, R. E Ferguson, A. Gardner, J. L McNamara, and P. Eghtesady
Cardiopulmonary bypass in the immature fetus through novel use of a mini-centrifugal pump
Perfusion, May 1, 2006; 21(3): 185 - 191.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
P. Eghtesady, J. A. Sedgwick, J. L. Schenbeck, C. Lam, J. Lombardi, R. Ferguson, A. Gardner, J. McNamara, and P. Manning
Maternal-Fetal Interactions in Fetal Cardiac Surgery
Ann. Thorac. Surg., January 1, 2006; 81(1): 249 - 256.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
A. Ikai, R. K. Riemer, C. Ramamoorthy, S. Malhatra, L. Cassorla, G. Amir, F. L. Hanley, and V. M. Reddy
Preliminary results of fetal cardiac bypass in nonhuman primates
J. Thorac. Cardiovasc. Surg., January 1, 2005; 129(1): 175 - 181.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
Y. Oishi, M. Masuda, T. Yasutsune, N. Boku, S. Tokunaga, S. Morita, and H. Yasui
Impaired Endothelial Function of the Umbilical Artery After Fetal Cardiac Bypass
Ann. Thorac. Surg., December 1, 2004; 78(6): 1999 - 2003.
[Abstract] [Full Text] [PDF]


Home page
PediatricsHome page
G. J. Peek and M. J. Elliott
Fetal Surgery for Congenital Diaphragmatic Hernia
Pediatrics, June 1, 2004; 113(6): 1810 - 1811.
[Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
A. Carotti, F. Emma, S. Picca, E. Iannace, S. B. Albanese, M. Grigioni, F. Meo, M. Sciarra, and R. M. Di Donato
Inflammatory response to cardiac bypass in ewe fetuses: effects of steroid administration or continuous hemodiafiltration
J. Thorac. Cardiovasc. Surg., December 1, 2003; 126(6): 1839 - 1848.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
A. J. Parry, E. Petrossian, D. B. McElhinney, V. M. Reddy, and F. L. Hanley
Neutrophil degranulation and complement activation during fetal cardiac bypass
Ann. Thorac. Surg., August 1, 2000; 70(2): 582 - 589.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
V. M. Reddy, D. B. McElhinney, H. A. Rajasinghe, J. R. Liddicoat, K. Hendricks-Munoz, J. R. Fineman, and F. L. Hanley
ROLE OF THE ENDOTHELIUM IN PLACENTAL DYSFUNCTION AFTER FETAL CARDIAC BYPASS
J. Thorac. Cardiovasc. Surg., February 1, 1999; 117(2): 343 - 351.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
R. S. Assad and F. L. Hanley
Editorial: Artificial placenta--a need for fetal surgery?
J. Thorac. Cardiovasc. Surg., May 1, 1998; 115(5): 1021 - 1025.
[Full Text] [PDF]


Home page
PerfusionHome page
J. J Sistino
Foetal bypass: concepts and controversies
Perfusion, March 1, 1998; 13(2): 111 - 117.
[Abstract] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
G. Champsaur, C. Vedrinne, S. Martinot, F. Tronc, J. Robin, J. Ninet, and M. Franck
FLOW-INDUCED RELEASE OF ENDOTHELIUM-DERIVED RELAXING FACTOR DURING PULSATILE BYPASS: EXPERIMENTAL STUDY IN THE FETAL LAMB
J. Thorac. Cardiovasc. Surg., November 1, 1997; 114(5): 738 - 745.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1996 by The Society of Thoracic Surgeons.