ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
John H. Calhoon
Mark C. Felger
Edward Y. Sako
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Calhoon, J. H.
Right arrow Articles by Sako, E. Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Calhoon, J. H.
Right arrow Articles by Sako, E. Y.
Related Collections
Right arrowRelated Article

Ann Thorac Surg 1996;62:91-93
© 1996 The Society of Thoracic Surgeons


Original Articles: Cardiovascular

Twelve-Hour Canine Heart Preservation With a Simple, Portable Hypothermic Organ Perfusion Device

John H. Calhoon, MD, Leonid Bunegin, BS, Jerry F. Gelineau, BS, Mark C. Felger, MD, Joseph J. Naples, MD, O. LaWayne Miller, MD, Edward Y. Sako, MDPhD

Division of Cardiothoracic Surgery, Department of Surgery and Department of Anesthesiology, The University of Texas Health Science Center at San Antonio, San Antonio, Texas

Background. Cardiac transplantation is limited to an ischemic time of around 6 hours by available preservation solution and technique. Complex organ preservation devices have been developed that extend this time to 24 hours or more, but are clinically impractical. This study evaluates a portable oxygen-driven organ perfusion device weighing approximately 13.5 kg.

Methods. Organs are perfused with the University of Wisconsin solution at low perfusion pressure using less than 400 L of oxygen per 12 hours. Left ventricular parameters were measured in anesthetized adult beagles to establish control values (n = 5). Hearts were procured after cardioplegia with 4°C University of Wisconsin solution, weighed, then stored for 12 hours in University of Wisconsin solution at 4°C. Hearts were perfused (n = 3) or nonperfused (n = 2) during storage. Organ temperature, partial pressure of oxygen in the aorta and right atrium, perfusion pressure, and aortic flow were recorded hourly in perfused hearts. After 12 hours, hearts were transplanted into littermates and left ventricular parameters measured after stabilization off bypass.

Results. Organ weight for both groups was unchanged. Nonperfused hearts required both pump and pharmacologic support with significantly depressed left ventricular function. Perfused hearts needed minimal pharmacologic support, with left ventricular end-diastolic pressure, cardiac output, and rate of change of left ventricular pressure showing no statistical difference from control.

Conclusions. These findings confirm the potential for extended metabolic support for ischemia-intolerant organs in a small, lightweight, easily portable preservation system.


Related Article

Discussion
Ann. Thorac. Surg. 1996 62: 93. [Extract] [Full Text]



This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
R. S. Poston, J. Gu, D. Prastein, F. Gage, J. W. Hoffman, M. Kwon, A. Azimzadeh, R. N. Pierson III, and B. P. Griffith
Optimizing Donor Heart Outcome After Prolonged Storage With Endothelial Function Analysis and Continuous Perfusion
Ann. Thorac. Surg., October 1, 2004; 78(4): 1362 - 1370.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Cell Physiol.Home page
J. O. Hegge, J. H. Southard, and R. A. Haworth
Preservation of metabolic reserves and function after storage of myocytes in hypothermic UW solution
Am J Physiol Cell Physiol, September 1, 2001; 281(3): C758 - C772.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
D. F Larson, L. B Gatewood, M. Bowers, G. Sethi, and J. G Copeland
Assessment of left ventricular compliance during heart preservation
Perfusion, January 1, 1998; 13(1): 67 - 75.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1996 by The Society of Thoracic Surgeons.