ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Tomio Abe
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Abe, T.
Right arrow Articles by Komatsu, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Abe, T.
Right arrow Articles by Komatsu, S.

Ann Thorac Surg 1996;61:1182-1187
© 1996 The Society of Thoracic Surgeons


Original Article: Cardiovascular

Ten Years' Experience of Aortic Valve Replacement With the Omnicarbon Valve Prosthesis

Tomio Abe, MD, Koji Kamata, MD, Kenji Kuwaki, MD, Kanshi Komatsu, MD, Sakuzo Komatsu, MD

Department of Thoracic and Cardiovascular Surgery, Sapporo Medical University School of Medicine, Sapporo, Japan

Accepted for publication December 9, 1995.

Background. There are few clinical studies on late follow-up of the Omnicarbon monoleaflet valve. We report our 10-year experience with this valve in the aortic position and also compare late hemodynamic performance of this valve with that of the CarboMedics valve in the aortic position.

Methods. From January 1985 to June 1995, 117 consecutive patients underwent aortic valve replacement (AVR) with the Omnicarbon valve. There were 66 men and 51 women aged 13 to 69 years (mean age, 50 ± 12 years). They were divided into three groups: group 1 (43 patients) had isolated AVR, group 2 (36) had AVR and concomitant operations, and group 3 (38) had combined AVR and mitral valve replacement. Follow-up was 96.6% complete and consisted of 882.7 patient-years (range, 2.5 to 10.6 years; mean follow-up, 7.5 ± 2.7 years).

Results. There were three early deaths (2.6%) and 18 late deaths (2.0%/patient-year) ten of which were due to valve-related causes and eight, nonvalve-related causes. Survival rates at 10 years in groups 1, 2, and 3 were 77.6%, 82.4%, and 78.6%, respectively. The overall rates of freedom from valve-related complications in groups 1, 2, and 3 at 10 years were 77.4%, 100%, and 80.9%, respectively. The rates of freedom from the following complications in groups 1, 2, and 3 at 10 years were as follows: thromboembolism-94.8%, 100%, and 89.4%, respectively; valvar thrombosis-95.0%, 100%, and 100%; anticoagulant-related hemorrhage-93.6%, 100%, and 93.4%; prosthetic valve endocarditis-93.0%, 100%, and 97.2%; and reoperation-90.6%, 100%, and 97.2%. There were no significant differences between groups. All survivors showed marked improvement in New York Heart Association functional class, from 86% in classes III and IV preoperatively to 96% in classes I and II postoperatively. The Omnicarbon valve exhibited no significant difference in hemodynamic performance after isolated AVR compared with the CarboMedics bileaflet valve at the same follow-up periods.

Conclusions. This 10-year study confirms that the Omnicarbon valve is a durable prosthesis and provides excellent functional improvement with low rates of thromboembolism and valvar thrombosis in the aortic position.




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
S. Torregrosa, J. Gomez-Plana, F. J. Valera, J. Caffarena, J. M. Maronas, F. Garcia-Sanchez, J. Peris, R. Frias, and J. M. Caffarena
Long-term clinical experience with the omnicarbon prosthetic valve
Ann. Thorac. Surg., September 1, 1999; 68(3): 881 - 886.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
J.B. Borman, W.G.B. Brands, L. Camilleri, M. Cotrufo, W. Daenen, I. Gandjbakhch, C. Infantes, A. Khayat, F. Laborde, A. Pellegrini, et al.
Bicarbon valve - European multicenter clinical evaluation
Eur. J. Cardiothorac. Surg., June 1, 1999; 13(6): 685 - 693.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
W.R. E. Jamieson, R. T. Miyagishima, G. L. Grunkemeier, E. Germann, C. Henderson, G. J. Fradet, L. H. Burr, and S. V. Lichtenstein
Bileaflet mechanical prostheses performance in mitral position
Eur. J. Cardiothorac. Surg., June 1, 1999; 15(6): 786 - 794.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1996 by The Society of Thoracic Surgeons.