ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Carlo Antona
Alessandro Parolari
Marco Zanobini
Vincenzo Arena
Paolo Biglioli
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Antona, C.
Right arrow Articles by Biglioli, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Antona, C.
Right arrow Articles by Biglioli, P.
Related Collections
Right arrowRelated Article

Ann Thorac Surg 1996;61:702-705
© 1996 The Society of Thoracic Surgeons


Original Article: Cardiovascular

Midterm Angiographic Study of Five Recycled Mammary Arteries During Four Coronary Redos

Carlo Antona, MD, Alessandro Parolari, MD, Marco Zanobini, MD, Vincenzo Arena, MD, Paolo Biglioli, MD

Department of Cardiac Surgery, University of Milan, Milano, Italy

Accepted for publication October 21, 1995.

Background. Recently the technical feasibility of reusing the left internal mammary artery (IMA) in coronary artery reoperation has been documented, but the patency of ``recycled'' IMAs has not yet been established.

Methods. In 4 patients undergoing coronary reoperation, five internal mammary arteries (3 left IMAs and 2 right IMAs) that were patent but severely stenotic at the anastomotic site were taken down and reused. In 2 cases the IMAs were reanastomosed to the same target coronary artery, in 2 cases the IMAs were rerouted to another coronary artery, and in 1 case an interposition of a short segment of the greater saphenous vein was needed to reach the target coronary artery.

Results. Angiographic midterm evaluation, performed between 7 and 35 months postoperatively, showed patency of all the reused grafts without stenoses.

Conclusions. When feasible, recycling of the IMAs may be considered if one or both IMAs have been previously used and are stenotic in the perianastomotic area, or when there is a stenosis in the native coronary artery distal to the anastomosis itself.


Related Article

Invited Commentary
Neal W. Salomon
Ann. Thorac. Surg. 1996 61: 705. [Extract] [Full Text]



This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
M. Agrifoglio, F. Barili, A. Parolari, E. Penza, M. Trezzi, G. Polvani, C. Antona, F. Alamanni, and P. Biglioli
Recycling thoracic arteries for redo coronary artery bypass grafting: Long-term follow-up
J. Thorac. Cardiovasc. Surg., July 1, 2007; 134(1): 233 - 235.
[Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
P. H. Noirhomme, M. J. Underwood, G. A. El Khoury, D. Glineur, B. Elias, Y. d'Udekem, and R. A. Dion
Recycling of arterial grafts during reoperative coronary artery operations
Ann. Thorac. Surg., March 1, 1999; 67(3): 641 - 644.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
V. Velebit, J. P. Maurice, C. Antona, A. Parolari, P. Biglioli, and L. Noyez
Recycling of Mammary Arteries
Ann. Thorac. Surg., September 1, 1996; 62(3): 947 - 949.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1996 by The Society of Thoracic Surgeons.