|
|
||||||||
Ann Thorac Surg 1996;61:76-81
© 1996 The Society of Thoracic Surgeons
Departments of Anesthesiology, Cardiovascular Perfusion, and Cardiac Surgery, Cardiovascular Center E. Malan, University Hospital S. Donato, Milan, Italy
Accepted for publication August 11, 1995.
Background. Heparin coating of the cardiopulmonary bypass circuit reduces the activation of the terminal part of the complement cascade. Conflicting data are reported concerning neutrophil activation and postoperative lung dysfunction. In this study, we compared three different types of oxygenator: a bubble oxygenator, a conventional hollow-fiber oxygenator, and a heparin-coated oxygenator and circuit.
Methods. Sixty patients undergoing myocardial revascularization were randomly assigned to one of three oxygenator groups. All the patients were free from preoperative lung dysfunction. Lung function was studied with repeated measurements of respiratory index, intrapulmonary shunt, alveolar dead space, ventilation/perfusion ratio, and static thoracopulmonary compliance.
Results. Immediately after cardiopulmonary bypass, the intrapulmonary shunt and respiratory index values in the bubble oxygenator and hollow-fiber oxygenator groups increased more than those in the heparin-coated oxygenator group. In the intensive care unit, the between-group difference in intrapulmonary shunt disappeared, but the within-group difference in respiratory index (from baseline) remained for the bubble oxygenator group. The other three variables did not significantly differ between groups. Intubation time and stay in the intensive care unit did not differ between groups.
Conclusions. Heparin-coated circuits exert a protective effect on pulmonary function. However, their use did not modify the postoperative clinical course of patients with normal lung function preoperatively.
This article has been cited by other articles:
![]() |
S. Jameel, S. Colah, and A. A Klein Recent advances in cardiopulmonary bypass techniques CEACCP, February 1, 2010; 10(1): 20 - 23. [Full Text] [PDF] |
||||
![]() |
G. S. Murphy, E. A. Hessel II, and R. C. Groom Optimal Perfusion During Cardiopulmonary Bypass: An Evidence-Based Approach Anesth. Analg., May 1, 2009; 108(5): 1394 - 1417. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. M. Carvalho, E. A Gabriel, and T. A Salerno Pulmonary Protection During Cardiac Surgery: Systematic Literature Review Asian Cardiovasc Thorac Ann, December 1, 2008; 16(6): 503 - 507. [Abstract] [Full Text] [PDF] |
||||
![]() |
O. Mangoush, S. Purkayastha, S. Haj-Yahia, J. Kinross, M. Hayward, F. Bartolozzi, A. Darzi, and T. Athanasiou Heparin-bonded circuits versus nonheparin-bonded circuits: an evaluation of their effect on clinical outcomes Eur J Cardiothorac Surg, June 1, 2007; 31(6): 1058 - 1069. [Abstract] [Full Text] [PDF] |
||||
![]() |
The Society of Thoracic Surgeons Blood Conservatio, V. A. Ferraris, S. P. Ferraris, S. P. Saha, E. A. Hessel II, C. K. Haan, B. D. Royston, C. R. Bridges, R. S.D. Higgins, G. Despotis, et al. Perioperative Blood Transfusion and Blood Conservation in Cardiac Surgery: The Society of Thoracic Surgeons and The Society of Cardiovascular Anesthesiologists Clinical Practice Guideline Ann. Thorac. Surg., May 1, 2007; 83(5_Supplement): S27 - S86. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Khoshbin, A. E. Dux, H. Killer, A. W Sosnowski, R. K Firmin, and G. J Peek A comparison of radiographic signs of pulmonary inflammation during ECMO between silicon and poly-methyl pentene oxygenators Perfusion, January 1, 2007; 22(1): 15 - 21. [Abstract] [PDF] |
||||
![]() |
M. E. Jessen Pro: Heparin-Coated Circuits Should be Used for Cardiopulmonary Bypass Anesth. Analg., December 1, 2006; 103(6): 1365 - 1369. [Full Text] [PDF] |
||||
![]() |
E. Khoshbin, C. Westrope, S. Pooboni, D. Machin, H. Killer, G. J Peek, A. W Sosnowski, and R. K Firmin Performance of polymethyl pentene oxygenators for neonatal extracorporeal membrane oxygenation: a comparison with silicone membrane oxygenators Perfusion, May 1, 2005; 20(3): 129 - 134. [Abstract] [PDF] |
||||
![]() |
R. de Vroege, W. van Oeveren, J. van Klarenbosch, W. Stooker, M. A. J. M. Huybregts, C. E. Hack, L. van Barneveld, L. Eijsman, and C. R. H. Wildevuur The Impact of Heparin-Coated Cardiopulmonary Bypass Circuits on Pulmonary Function and the Release of Inflammatory Mediators Anesth. Analg., June 1, 2004; 98(6): 1586 - 1594. [Abstract] [Full Text] [PDF] |
||||
![]() |
W.-J. Luo, X. Ling, and R.-M. Huang Effects of aminophylline on cytokines and pulmonary function in patients undergoing valve replacement Eur J Cardiothorac Surg, May 1, 2004; 25(5): 766 - 771. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. S. Aldea, L. O. Soltow, W. L. Chandler, C. M. Triggs, C. R. Vocelka, G. I. Crockett, Y. T. Shin, W. E. Curtis, and E. D. Verrier Limitation of thrombin generation, platelet activation, and inflammation by elimination of cardiotomy suction in patients undergoing coronary artery bypass grafting treated with heparin-bonded circuits J. Thorac. Cardiovasc. Surg., April 1, 2002; 123(4): 742 - 755. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. S.H. Ng, S. Wan, A. P.C. Yim, and A. A. Arifi Pulmonary Dysfunction After Cardiac Surgery* Chest, April 1, 2002; 121(4): 1269 - 1277. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. A. Hennein Inflammation After Cardiopulmonary Bypass: Therapy for the Postpump Syndrome Seminars in Cardiothoracic and Vascular Anesthesia, September 1, 2001; 5(3): 236 - 255. [Abstract] [PDF] |
||||
![]() |
L.-C. Hsu Heparin-coated cardiopulmonary bypass circuits: current status Perfusion, September 1, 2001; 16(5): 417 - 428. [Abstract] [PDF] |
||||
![]() |
S. Svenmarker, E. Sandstrom, T. Karlsson, S. Haggmark, E. Jansson, M. Appelblad, R. Lindholm, and T. Aberg Neurological and general outcome in low-risk coronary artery bypass patients using heparin coated circuits Eur J Cardiothorac Surg, January 1, 2001; 19(1): 47 - 53. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. A. Richter, H. Meisner, P. Tassani, A. Barankay, W. Dietrich, and S. L. Braun Drew-Anderson technique attenuates systemic inflammatory response syndrome and improves respiratory function after coronary artery bypass grafting Ann. Thorac. Surg., January 1, 2000; 69(1): 77 - 83. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Struber, J. T. Cremer, B. Gohrbandt, C. Hagl, M. Jankowski, B. Volker, H. Ruckoldt, M. Martin, and A. Haverich Human cytokine responses to coronary artery bypass grafting with and without cardiopulmonary bypass Ann. Thorac. Surg., October 1, 1999; 68(4): 1330 - 1335. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. P. Wendel and G. Ziemer Coating-techniques to improve the hemocompatibility of artificial devices used for extracorporeal circulation Eur J Cardiothorac Surg, September 1, 1999; 16(3): 342 - 350. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. M. McCarthy, J.-P. P. Yared, R. C. Foster, D. A. Ogella, J. A. Borsh, and D. M. Cosgrove III A prospective randomized trial of Duraflo II heparin-coated circuits in cardiac reoperations Ann. Thorac. Surg., May 1, 1999; 67(5): 1268 - 1273. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Ranucci, A. Mazzucco, R. Pessotto, G. Grillone, V. Casati, L. Porreca, R. Maugeri, M. Meli, P. Magagna, S. Cirri, et al. Heparin-coated circuits for high-risk patients: a multicenter, prospective, randomized trial Ann. Thorac. Surg., April 1, 1999; 67(4): 994 - 1000. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. Videm, T. E. Mollnes, E. Fosse, B. Mohr, MD, K. Bergh, T.-A. Hagve, A. O. Aasen, and J. L. Svennevig HEPARIN-COATED CARDIOPULMONARY BYPASS EQUIPMENT. I. BIOCOMPATIBILITY MARKERS AND DEVELOPMENT OF COMPLICATIONS IN A HIGH-RISK POPULATION J. Thorac. Cardiovasc. Surg., April 1, 1999; 117(4): 794 - 802. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Zund, A. L. Dzus, R. Pretre, U. Niederhauser, P. Vogt, and M. Turina Endothelial cell injury in cardiac surgery: salicylate may be protective by reducing expression of endothelial adhesion molecules Eur J Cardiothorac Surg, March 1, 1998; 13(3): 293 - 297. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. A. Shastri, G. L. Logue, M. P. Stern, S. Rehman, and S. Raza COMPLEMENT ACTIVATION BY HEPARIN-PROTAMINE COMPLEXES DURING CARDIOPULMONARY BYPASS: EFFECT OF C4A NULL ALLELE J. Thorac. Cardiovasc. Surg., September 1, 1997; 114(3): 482 - 488. [Abstract] [Full Text] |
||||
![]() |
M Ranucci, G Soro, A Frigiola, L Menicanti, A Ditta, G Candido, and S Tambalo Normothermic perfusion and lung function after cardiopulmonary bypass: effects in pulmonary risk patients Perfusion, September 1, 1997; 12(5): 309 - 315. [Abstract] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |