|
|
||||||||
Ann Thorac Surg 1996;61:291-295
© 1996 The Society of Thoracic Surgeons
Department of Surgery, Baylor College of Medicine, The Methodist Hospital, Houston, Texas
Abstract
Background. Bio-Medicus centrifugal ventricular support has been used widely for postcardiotomy cardiac failure. The purpose of this study was to review a large series of support patients examining complications and outcomes.
Methods. One hundred twenty-nine patients undergoing cardiac operations at The Methodist Hospital in Houston, Texas, were placed on Bio-Medicus centrifugal ventricular support for postcardiotomy cardiac failure; 102 were male and 27 were female with a mean age of 61.6 years. These patients were selected for ventricular support based solely on failure to be weaned from cardiopulmonary bypass or progressive postcardiotomy cardiac failure shortly after arrival in the intensive care unit.
Results. These patients experienced numerous complications including coagulopathy, renal insufficiency or failure, sepsis, neurologic deficits, ventricular failure, arrhythmias, and death; 56.3% of patients were weaned from mechanical support and 21.0% were discharged alive. Causes of death included ventricular failure (62.4%), arrhythmias (12.9%), triage (6.9%), perioperative myocardial infarction or cardiac arrest (5.0%), coagulopathy (4.0%), sepsis syndrome (4.0%), cardiac graft failure (3.0%), and device related (1.0%). The one device-related death was a venous cannula dislodgment in the intensive care unit with subsequent exsanguination. Device-related complications were seen in only 1.6% of patients.
Conclusions. Bio-Medicus centrifugal ventricular support can be implemented rapidly and relatively easily. There are few device-related complications and the cost is relatively inexpensive compared with other assist systems. This series demonstrates that a substantial number of patients who experience reversible postcardiotomy myocardial injury will benefit from temporary centrifugal ventricular support.
This article has been cited by other articles:
![]() |
E. C. McGee Jr., P. M. McCarthy, and N. Moazami Temporary Mechanical Circulatory Support Card. Surg. Adult, January 1, 2008; 3(2008): 507 - 534. [Full Text] |
||||
![]() |
M. Mert, A. Akcevin, C. E Yildiz, and K. Suzer Postoperative Mechanical Circulatory Support with Biomedicus Centrifugal Pump Asian Cardiovasc Thorac Ann, March 1, 2005; 13(1): 38 - 41. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Taghavi, A. Zuckermann, J. Ankersmit, G. Wieselthaler, A. Rajek, G. Laufer, E. Wolner, and M. Grimm Extracorporeal Membrane Oxygenation is Superior to Right Ventricular Assist Device for Acute Right Ventricular Failure After Heart Transplantation Ann. Thorac. Surg., November 1, 2004; 78(5): 1644 - 1649. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. P. Siegenthaler, K. Brehm, T. Strecker, T. Hanke, A. Notzold, M. Olschewski, M. Weyand, H. Sievers, and F. Beyersdorf The Impella Recover microaxial left ventricular assist device reduces mortality for postcardiotomy failure: a three-center experience J. Thorac. Cardiovasc. Surg., March 1, 2004; 127(3): 812 - 822. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Moazami and P. M. McCarthy Temporary Circulatory Support Card. Surg. Adult, January 1, 2003; 2(2003): 495 - 520. [Full Text] |
||||
![]() |
C Gobel, A Arvand, G Rau, H Reul, B Meyns, W Flameng, R Eilers, and O Marseille A new rotary blood pump for versatile extracorporeal circulation: the DeltaStreamTM Perfusion, September 1, 2002; 17(5): 373 - 382. [Abstract] [PDF] |
||||
![]() |
F. B.Y. Hoy, D. K. Mueller, D. M. Geiss, J. R. Munns, L. M. Bond, C. E. Linett, and R. C. Gomez Bridge to recovery for postcardiotomy failure: is there still a role for centrifugal pumps? Ann. Thorac. Surg., October 1, 2000; 70(4): 1259 - 1263. [Abstract] [Full Text] [PDF] |
||||
![]() |
A K Mahmood, J M Courtney, S Westaby, M Akdis, and H Reul Critical review of current left ventricular assist devices Perfusion, September 1, 2000; 15(5): 399 - 420. [PDF] |
||||
![]() |
B. Meyns, P. Sergeant, P. Wouters, F. Casselman, P. Herijgers, W. Daenen, K. Bogaerts, and W. Flameng Mechanical support with microaxial blood pumps for postcardiotomy left ventricular failure: Can outcome be predicted? J. Thorac. Cardiovasc. Surg., August 1, 2000; 120(2): 393 - 400. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. M Reul and M. Akdis Blood pumps for circulatory support Perfusion, July 1, 2000; 15(4): 295 - 311. [PDF] |
||||
![]() |
J. J. Curtis, J. T. Walls, C. C. Wagner-Mann, R. A. Schmaltz, T. L. Demmy, C. A. McKenney, and F. A. Mann Centrifugal pumps: description of devices and surgical techniques Ann. Thorac. Surg., August 1, 1999; 68(2): 666 - 671. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. G. Smedira, C. C. Hlozek, and P. M. McCarthy Mechanical Support After Cardiac Surgery Seminars in Cardiothoracic and Vascular Anesthesia, March 1, 1998; 2(1): 66 - 77. [Abstract] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |