Ann Thorac Surg 1995;60:1121-1123
© 1995 The Society of Thoracic Surgeons
Department of Cardiovascular Surgery, The Heart Institute of Japan, Tokyo Women's Medical College, Tokyo, Japan
Accepted for publication April 21, 1995.
Stenting seems to be a definitive procedure after failed balloon coronary angioplasty. This report describes a case of redo coronary bypass grafting and concomitant resection of enlarging false aneurysm of a saphenous vein graft that developed secondary to stenting for recurrent stenosis after serial percutaneous transluminal coronary angioplasty. It warns us of a pitfall in catheter intervention in an aged saphenous vein graft.
This article has been cited by other articles:
![]() |
S. Gupta, T. Khan, L. W. Stephenson, D. Cooley, and J. Schnader Clinical Conference on Management Dilemmas : A Growing Vascular Mass in the Chest Chest, December 1, 2000; 118(6): 1769 - 1775. [Full Text] [PDF] |
||||
![]() |
I. Trop, L. Samson, M.-P. Cordeau, P. Leblanc, and E. Therasse Anterior Mediastinal Mass in a Patient With Prior Saphenous Vein Coronary Artery Bypass Grafting Chest, February 1, 1999; 115(2): 572 - 576. [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |