ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Urban Lönn
Hans Granfeldt
Henrik Casimir-Ahn
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lönn, U.
Right arrow Articles by Casimir-Ahn, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lönn, U.
Right arrow Articles by Casimir-Ahn, H.

Ann Thorac Surg 1995;60:1067-1071
© 1995 The Society of Thoracic Surgeons


Original Articles: Cardiovascular

Hemopump Treatment in Patients With Postcardiotomy Heart Failure

Urban Lönn, MD, Bengt Peterzén, MD, Hans Granfeldt, MD, Ankica Babic, PhD, Henrik Casimir-Ahn, MD, PhD

Linköping Heart Center, University of Linköping, Linköping, Sweden

Accepted for publication May 11, 1995.

Background. This study examined the use of the Hemopump to treat low cardiac output syndrome after cardiopulmonary bypass.

Methods. We used the Hemopump temporary cardiac assist system in 29 patients with severe left ventricular dysfunction after open heart operations from September 1991 to November 1994.

Results. Five patients were excluded from the study due to initial patient/device-related problems. Ten patients died in the operating room or early during the stay in the intensive care unit due to progressive biventricular failure. Fourteen patients (58.3%) were weaned from the device, and all of them were later discharged. In a subgroup of patients (54%) in whom we had a more aggressive approach for early insertion of the pump, the survival rate was 85%. Preoperative Higging risk score was significantly related to survival.

Conclusions. The Hemopump can effectively unload a failing left ventricle with preservation of multiorgan perfusion. A minor decrease in kidney function was observed in most patients, but none of the surviving patients needed hemodialysis. One patient required a short period of peritoneal dialysis to get rid of fluid overload. Hemolysis or platelet dysfunction was not a clinical problem.




This article has been cited by other articles:


Home page
ChestHome page
K. D. Reesink, A. L. Dekker, V. van Ommen, C. Soemers, G. G. Geskes, F. H. van der Veen, and J. G. Maessen
Miniature Intracardiac Assist Device Provides More Effective Cardiac Unloading and Circulatory Support During Severe Left Heart Failure Than Intraaortic Balloon Pumping
Chest, September 1, 2004; 126(3): 896 - 902.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
U. Lonn, J. Wulff, K.-Y. Keck, B. Wranne, P. Ask, B. Peterzen, and H. Casimir-Ahn
Flow Characteristics of the Hemopump: An Experimental In Vitro Study
Ann. Thorac. Surg., January 1, 1997; 63(1): 162 - 166.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
B. Peterzen, U. Lonn, A. Babic, H. Granfeldt, H. Casimir-Ahn, and H. Rutberg
Postoperative Management of Patients With Hemopump Support After Coronary Artery Bypass Grafting
Ann. Thorac. Surg., August 1, 1996; 62(2): 495 - 500.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1995 by The Society of Thoracic Surgeons.