ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Mohammad Bashar Izzat
Inderpaul Birdi
Alan J. Bryan
Gianni D. Angelini
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Izzat, M. B.
Right arrow Articles by Angelini, G. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Izzat, M. B.
Right arrow Articles by Angelini, G. D.

Ann Thorac Surg 1995;60:1048-1052
© 1995 The Society of Thoracic Surgeons


Original Articles: Cardiovascular

Evaluation of the Hemodynamic Performance of Small CarboMedics Aortic Prostheses Using Dobutamine-Stress Doppler Echocardiography

Mohammad Bashar Izzat, FRCS, Inderpaul Birdi, FRCS, Peter Wilde, FRCR, Alan J. Bryan, FRCS, Gianni D. Angelini, FRCS

Departments of Cardiac Surgery and Cardiac Radiology, University of Bristol and Bristol Royal Infirmary, Bristol, United Kingdom

Accepted for publication April 29, 1995.

Background. The well-known correlation between prosthetic valve orifice area and transvalvular gradients has raised concerns about the presence of significant residual gradients when the size of the prosthesis that can be implanted is limited by the presence of a small aortic annulus.

Methods. Dobutamine-stress Doppler echocardiography was used to evaluate the hemodynamic performance of small CarboMedics aortic prostheses (19 mm and 21 mm) in 18 patients (16 women; mean age, 64 years) who had undergone aortic valve replacement 23.5 ± 19 months (standard deviation) previously. Dobutamine infusion was started at a rate of 5 µg • kg-1 min-2 and increased to 10 and 20 µg • kg-1 min-2 at 15-minute intervals. Pulsed and continuous wave Doppler studies were performed at rest and at the end of each stage. Effective orifice area, performance index, and discharge coefficient of both valves were calculated, and peak and mean velocity and pressure drop across the prostheses were measured.

Results. Heart rate and cardiac output increased by 74% and 94%, respectively, and mean arterial blood pressure decreased by 9% at maximum stress. Effective orifice area, discharge coefficient, and performance index were comparable in both valve sizes at rest and maximum stress. Also, there was no significant difference in mean transvalvular pressure drop (gradient) for 19-mm and 21-mm prostheses at rest (8.1 ± 8.4 and 4.8 ± 3.8 mm Hg) or maximum stress (15.1 ± 14.2 and 8.8 ± 5.8 mm Hg, respectively). No significant correlation could be demonstrated between transvalvular pressure drop and patient's body surface area.

Conclusions. These data show that 19-mm and 21-mm CarboMedics aortic prostheses exhibit equally favorable hemodynamic performance with minimal pressure gradient, both at rest and under stress conditions.




This article has been cited by other articles:


Home page
ANGIOLOGYHome page
G. R. Rezaian, K. Aghasadeghi, and J. Kojuri
Evaluation of the Hemodynamic Performance of St.Jude Mitral Prostheses: A Pilot Study by Dobutamine-Stress Doppler Echocardiography
Angiology, January 1, 2005; 56(1): 81 - 86.
[Abstract] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
I. Kadir, C. Walsh, P. Wilde, A. J. Bryan, and G. D. Angelini
Comparison of exercise and dobutamine echocardiography in the haemodynamic assessment of small size mechanical aortic valve prostheses
Eur. J. Cardiothorac. Surg., April 1, 2002; 21(4): 692 - 697.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
I. Kadir, I. Y.P. Wan, C. Walsh, P. Wilde, A. J. Bryan, and G. D. Angelini
Hemodynamic performance of the 21-mm Sorin Bicarbon mechanical aortic prostheses using dobutamine Doppler echocardiography
Ann. Thorac. Surg., July 1, 2001; 72(1): 49 - 53.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
I. Knez, R. Rienmuller, R. Maier, P. Rehak, B. Schrottner, H. Machler, M. Anelli-Monti, and B. Rigler
Left ventricular architecture after valve replacement due to critical aortic stenosis: an approach to dis-/qualify the myth of valve prosthesis-patient mismatch?
Eur. J. Cardiothorac. Surg., June 1, 2001; 19(6): 797 - 805.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
A. D. Maslow, J. M. Haering, S. Heindel, J. Mashikian, R. Levine, and P. Douglas
An Evaluation of Prosthetic Aortic Valves Using Transesophageal Echocardiography: The Double-Envelope Technique
Anesth. Analg., September 1, 2000; 91(3): 509 - 516.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. B. Izzat, I. Kadir, B. Reeves, P. Wilde, A. J. Bryan, and G. D. Angelini
Patient-prosthesis mismatch is negligible with modern small-size aortic valve prostheses
Ann. Thorac. Surg., November 1, 1999; 68(5): 1657 - 1660.
[Abstract] [Full Text] [PDF]


Home page
Asian Cardiovasc. Thorac. Ann.Home page
N. Cam, H. Gercekoglu, S. Celik, M. Gursurer, G. Tayyareci, H. Karabulut, A. Narin, T. Tezel, and B. Yigiter
Dobutamine Stress Test to Evaluate Different Sizes of Prosthetic Aortic Valves
Asian Cardiovasc Thorac Ann, September 1, 1998; 6(3): 166 - 173.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
J.-F. Obadia, Y. A. Martelloni, O. H. Bastien, G. M. Durand de Gevigney, and J.-F. Chassignolle
Long-Term Follow-up of Small (Size 20 and 21) Medtronic-Hall Aortic Valve Prostheses
Ann. Thorac. Surg., August 1, 1997; 64(2): 421 - 425.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
M. B. Izzat and A. P. C. Yim
Assessment of the hemodynamic performance of small-size aortic valve prostheses
J. Thorac. Cardiovasc. Surg., June 1, 1997; 113(6): 1121 - 1122.
[Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
J. R. Gonzalez-Juanatey
Assessment of the hemodynamic performance of small-size aortic valve prostheses
J. Thorac. Cardiovasc. Surg., June 1, 1997; 113(6): 1122 - 1123.
[Full Text]


Home page
Ann. Thorac. Surg.Home page
I. Kadir, M. B. Izzat, P. Wilde, B. Reeves, A. J. Bryan, and G. D. Angelini
Dynamic Evaluation of the 21-mm Medtronic Intact Aortic Bioprosthesis by Dobutamine Echocardiography
Ann. Thorac. Surg., April 1, 1997; 63(4): 1128 - 1132.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
T. Carrel, U. Zingg, R. Jenni, B. Aeschbacher, and M. I. Turina
Early In Vivo Experience With the Hemodynamic Plus St. Jude Medical Heart Valves in Patients With Narrowed Aortic Annulus
Ann. Thorac. Surg., May 1, 1996; 61(5): 1418 - 1422.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
M. B. Izzat, M. Caputo, and G. D. Angelini
Evaluation of the Hemodynamic Performance of Stentless Porcine Aortic Valves
Ann. Thorac. Surg., November 1, 1995; 60(5): 1461 - 1461.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1995 by The Society of Thoracic Surgeons.