Extracorporeal circulation with exposure of blood to foreign surfaces causes activation of different defense systems, eg, white cells. Several potent mediators are released into plasma, capable of causing harmful effects to different organs, contributing to postoperative morbidity after operations using cardiopulmonary bypass. The eosinophil granulocyte has not previously been investigated in this respect. We studied two of its activation products, eosinophil cationic protein and eosinophil protein X in coronary bypass patients. In 17 control patients, plasma levels of eosinophil cationic protein and eosinophil protein X increased considerably during cardiopulmonary bypass. In 19 patients with heparin-coated cardiopulmonary bypass equipment the levels were significantly reduced, indicating improved biocompatibility of the cardiopulmonary bypass circuit. The heparin-coated surface causes less activation of eosinophils; also, released eosinophil cationic protein is bound to the heparinized surface.
This article has been cited by other articles:
![]() |
O. Mangoush, S. Purkayastha, S. Haj-Yahia, J. Kinross, M. Hayward, F. Bartolozzi, A. Darzi, and T. Athanasiou Heparin-bonded circuits versus nonheparin-bonded circuits: an evaluation of their effect on clinical outcomes Eur. J. Cardiothorac. Surg., June 1, 2007; 31(6): 1058 - 1069. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. N Hoel, V. Videm, S. T Baksaas, T. E Mollnes, F. Brosstad, and J. L Svennevig Comparison of a Duraflo II-coated cardiopulmonary bypass circuit and a trillium-coated oxygenator during open-heart surgery Perfusion, May 1, 2004; 19(3): 177 - 184. [Abstract] [PDF] |
||||
![]() |
V. Videm, T. E. Mollnes, E. Fosse, B. Mohr, MD, K. Bergh, T.-A. Hagve, A. O. Aasen, and J. L. Svennevig HEPARIN-COATED CARDIOPULMONARY BYPASS EQUIPMENT. I. BIOCOMPATIBILITY MARKERS AND DEVELOPMENT OF COMPLICATIONS IN A HIGH-RISK POPULATION J. Thorac. Cardiovasc. Surg., April 1, 1999; 117(4): 794 - 802. [Abstract] [Full Text] [PDF] |
||||
![]() |
C B. Mahoney Heparin-bonded circuits: clinical outcomes and costs Perfusion, May 1, 1998; 13(3): 192 - 204. [Abstract] [PDF] |
||||
![]() |
L. K von Segesser Surface coating of cardiopulmonary bypass circuits Perfusion, May 1, 1996; 11(3): 241 - 245. [PDF] |
||||
![]() |
E. Ovrum, L. Nilsson, P. Venge, J. W. Borowiec, and S. Thelin Eosinophil Granulocyte Activation and Heparin-Coated Cardiopulmonary Bypass Ann. Thorac. Surg., March 1, 1996; 61(3): 1038 - 1039. [Full Text] |
||||