ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Scott A. Buchanan
Michael C. Mauney
Mark A. Groh
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Buchanan, S. A.
Right arrow Articles by Tribble, C. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Buchanan, S. A.
Right arrow Articles by Tribble, C. G.

Ann Thorac Surg 1994;58:1547-1549
© 1994 The Society of Thoracic Surgeons


Articles

Ambulatory intraaortic balloon counterpulsation

Scott A. Buchanan, MD, Scott E. Langenburg, MD, Michael C. Mauney, MD, Lorne H. Blackbourne, MD, Mark A. Groh, MD, James D. Bergin, MD, Curtis G. Tribble, MD*

Division of Thoracic and Cardiovascular Surgery, Department of surgery. University of Virginia Health Sciences Center, Charlottesville, Virginia USA

Accepted for publication July 6, 1994.

* Address reprint requests to Dr Tribble, Department of Surgery, University of Virginia Health Sciences Center, Box 181, Charlottesville, VA 22908.

A technique is described for the retroperitoneal placement of a balloon pump that preserves patient mobility. This technique may be superior to standard femoral placement when prolonged support is required for cardiac transplant candidates awaiting donor organs.




This article has been cited by other articles:


Home page
The ESC Textbook of Acute and Intensive Cardiac CareHome page
K. Werdan, M. Russ, and M. Buerke
Chapter 29 The intra-aortic balloon pump
The ESC Textbook of Acute and Intensive Cardiac Care, December 1, 2010; 1(1): med-9780199584314-chapter - med-9780199584314-chapter.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. E. Legget, W. S. Peters, F. P. Milsom, J. S. Clark, T. M. West, R. L. French, and A. F. Merry
Extra-Aortic Balloon Counterpulsation: An Intraoperative Feasibility Study
Circulation, August 30, 2005; 112(9_suppl): I-26 - I-31.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
R. P. Cochran, T. D. Starkey, A. L. Panos, and K. S. Kunzelman
Ambulatory intraaortic balloon pump use as bridge to heart transplant
Ann. Thorac. Surg., September 1, 2002; 74(3): 746 - 751.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. R. Patel, S. A. Buchanan, J. D. Bergin, S. M. Fiser, A. K. Kaza, and C. G. Tribble
Update 2001: Ambulatory intraaortic balloon counterpulsation
Ann. Thorac. Surg., September 1, 2001; 72(3): 975 - 975.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1994 by The Society of Thoracic Surgeons.