ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Izzat, M.
Right arrow Articles by Bryan, A. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Izzat, M.
Right arrow Articles by Bryan, A. J.

The Annals of Thoracic Surgery, Vol 58, 1486-1489, Copyright © 1994 by The Society of Thoracic Surgeons


ARTICLES

Transesophageal echocardiographic measurements of cardiac output in cardiac surgical patients

MBB Izzat, IA Regragui, P Wilde, GD Angelini and AJ Bryan
Department of Cardiac Surgery, University of Bristol, United Kingdom.

Transesophageal echocardiography is becoming increasingly popular as a method of intraoperative monitoring because it can be performed continuously, does not transgress the sterile operative field, and provides data with regard to valve function, ventricular volumes, and contractility. Recently it was suggested that it can be used to measure cardiac output; however, controversy remains regarding its accuracy. Cardiac output was measured simultaneously by transesophageal echocardiography (using a 5-MHz pulse-wave Doppler, single-plane viewing probe) and by the thermodilution method in 21 patients undergoing open heart operations. The cardiac outputs measured by thermodilution correlated poorly (r = 0.45) with the transesophageal values derived from the left ventricular cross-sectional area, and the mean difference was 0.47 +/- 2.17 (standard deviation) L.min-1, giving limits of agreement of from -3.87 to +4.81 L.min-1. Cardiac outputs measured by thermodilution correlated well (r = 0.95) with transesophageal Doppler values derived from pulmonary artery flow velocity, with a mean difference of 0.12 +/- 0.45 L.min-1 and narrow limits of agreement of from -0.78 to +1.02 L.min-1. Based on our findings, transesophageal Doppler echocardiographic determination of cardiac output using pulmonary artery flow measurements can provide accurate hemodynamic data in patients undergoing cardiac operations.


This article has been cited by other articles:


Home page
ChestHome page
J. I. Poelaert and G. Schupfer
Hemodynamic Monitoring Utilizing Transesophageal Echocardiography: The Relationships Among Pressure, Flow, and Function
Chest, January 1, 2005; 127(1): 379 - 390.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1994 by The Society of Thoracic Surgeons.