The Annals of Thoracic Surgery, Vol 58, 1199-1204, Copyright © 1994 by The Society of Thoracic Surgeons
G Wright
Reasons for fluctuations in the popularity of pulsatile cardiopulmonary
bypass are discussed. The advantages of pulsatile flow have previously been
stated in terms of physiologic parameters. This has produced a weak
theoretic framework that has led to serious misunderstandings of the
fundamental mechanical properties of pulsatile flow. Failure to consider
these properties in the past may have allowed modified roller pumps to be
accepted as "pulsatile," even though their pulsatile power outputs are
small compared with those of the human heart. A fresh approach is required
in which pulsatile blood flow is analyzed in terms of hemodynamic power and
impedance parameters.
ARTICLES
Hemodynamic analysis could resolve the pulsatile blood flow controversy
Department of Biomedical Engineering and Medical Physics, University of Keele, Staffordshire, England.
This article has been cited by other articles:
![]() |
J. W. Hammon Extracorporeal Circulation: Perfusion System Card. Surg. Adult, January 1, 2008; 3(2008): 350 - 370. [Full Text] |
||||
![]() |
A. R. Travis, G. A. Giridharan, G. M. Pantalos, R. D. Dowling, S. D. Prabhu, M. S. Slaughter, M. Sobieski, A. Undar, D. J. Farrar, and S. C. Koenig Vascular pulsatility in patients with a pulsatile- or continuous-flow ventricular assist device J. Thorac. Cardiovasc. Surg., February 1, 2007; 133(2): 517 - 524. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Undar and J. L. Myers Arterial pressure and pump flow rate during long-term pulsatile and nonpulsatile cardiac support. Ann. Thorac. Surg., March 1, 2005; 79(3): 1093 - 1094. [Full Text] [PDF] |
||||
![]() |
E. A. Hessel II and L. H. Edmunds Jr. Extracorporeal Circulation: Perfusion Systems Card. Surg. Adult, January 1, 2003; 2(2003): 317 - 338. [Full Text] |
||||
![]() |
A. Undar, K. M Koenig, O H Frazier, and C. D Fraser Jr Impact of membrane oxygenators on pulsatile versus nonpulsatile perfusion in a neonatal model Perfusion, March 1, 2000; 15(2): 111 - 120. [Abstract] [PDF] |
||||
![]() |
A. Undar and C. D. Fraser Jr Balloon pump-induced pulsatile perfusion during cardiopulmonary bypass does not improve brain oxygenation J. Thorac. Cardiovasc. Surg., January 1, 2000; 119(1): 189 - 189. [Full Text] |
||||
![]() |
Y. Kadoi and S. Saito Balloon pump-induced pulsatile perfusion during cardiopulmonary bypass does not improve brain oxygenation J. Thorac. Cardiovasc. Surg., January 1, 2000; 119(1): 189 - 190. [Full Text] |
||||
![]() |
E. Silistreli, H. Catalyurek, N. Sariosmanoglu, U. Acikel, E. Hazan, and O. Oto Effects on the Endocrine System of Pulsatile and Nonpulsatile Perfusion in Heart Surgery Asian Cardiovasc Thorac Ann, March 1, 1999; 7(1): 18 - 22. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Undar and C. D. Fraser Jr. The relation between pump flow rate and pulsatility on cerebral hemodynamics during pediatric cardiopulmonary bypass J. Thorac. Cardiovasc. Surg., September 1, 1998; 116(3): 530 - 531. [Full Text] |
||||
![]() |
A. Undar, M. C Holland, R. V Howelton, C. K Benson, J. R Ybarra, O L. Miller, M. M Rossbach, T. M Runge, S. B Johnson, E. Y Sako, et al. Testing neonate-infant membrane oxygenators with the University of Texas neonatal pulsatile cardiopulmonary bypass system in vitro Perfusion, September 1, 1998; 13(5): 346 - 352. [Abstract] [PDF] |
||||
![]() |
A Undar Letter to the editor Perfusion, May 1, 1998; 13(3): 215 - 216. [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |