Ann Thorac Surg 1994;58:890-891
© 1994 The Society of Thoracic Surgeons
Department of Anesthesiology, Cardiovascular Surgery, and Cardiology, CHU du Sart-Tilman, Liege, Belgium
Received for publication December 30, 1993.
* Address reprint requests to Dr Canivet, Unité de Soins Intensits, CHU Liège, Domaine Universitaire du Sart-Tilman (B 35), 4000 Liège, Belgium.
We report a case of mechanical flow obstruction after heart transplantation caused by a prominent left atrium suture with a "purscstring" effect. The diagnosis was achieved by transesophageal echocardiography. The mean transstenotic gradient was measured at 13 mm Hg. Because of the profound hemodynamic and multisystemic failure, no surgical correction was attempted. The postmortem examination confirmed the stenosis at the level of the left atrium.
This article has been cited by other articles:
![]() |
Y.-C. Huang, Y.-J. Cheng, Y.-H. Lin, M.-J. Wang, and S.-K. Tsai Graft Failure Caused by Pulmonary Venous Obstruction Diagnosed by Intraoperative Transesophageal Echocardiography During Lung Transplantation Anesth. Analg., September 1, 2000; 91(3): 558 - 560. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. M. Caramutti, J. C. Zaidman, J. A. Abud, and E. D. Gabe Azygos vein diverticulum Ann. Thorac. Surg., August 1, 2000; 70(2): 665 - 666. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Uematsu, M. Okada, and M. Uematsu Primary Venous Aneurysms: Case Reports Angiology, March 1, 1999; 50(3): 239 - 244. [Abstract] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |