ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Davis, D. A.
Right arrow Articles by Spitzer, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Davis, D. A.
Right arrow Articles by Spitzer, A.

The Annals of Thoracic Surgery, Vol 57, 846-849, Copyright © 1994 by The Society of Thoracic Surgeons


ARTICLES

High-frequency jet versus conventional ventilation in infants undergoing Blalock-Taussig shunts

DA Davis, PA Russo, JS Greenspan, G Speziali and A Spitzer
Department of Anesthesia and Critical Care, St. Christopher's Hospital for Children, Temple University School of Medicine, Philadelphia, Pennsylvania.

Nine infants undergoing modified Blalock-Taussig shunts were randomized to both high-frequency jet ventilation (HFJV) and conventional ventilation (CV). Vital signs, blood gases, mean airway pressure, lung mechanics, functional residual capacity, and lung movement were compared on both modes of ventilation keeping peak inspiratory and expiratory pressures constant. The mean airway pressure was lower on HFJV than on CV (8.5 versus 10.9 cm H2O). Arterial partial pressure of oxygen was greater on HFJV than on CV (55 versus 46 mm Hg), arterial partial pressure of carbon dioxide was lower on HFJV than on CV (28 versus 37 mm Hg), whereas compliance (0.54 versus 0.56 mL.cm H2O-1.kg- 1). resistance (110 versus 95 cm H2O/L.s), and functional residual capacity (23 versus 22.5 mL/kg) remained the same. Lung movement and degree of retraction necessary for surgical exposure as evaluated by an independent observer was less with HFJV compared with CV. Compared with CV during the creation of Blalock-Taussig shunts, HFJV provides better gas exchange at lower mean airway pressure with similar lung function, lung volume, and hemodynamics.