The Annals of Thoracic Surgery, Vol 57, 846-849, Copyright © 1994 by The Society of Thoracic Surgeons
High-frequency jet versus conventional ventilation in infants undergoing Blalock-Taussig shunts
DA Davis, PA Russo, JS Greenspan, G Speziali and A Spitzer
Department of Anesthesia and Critical Care, St. Christopher's Hospital for Children, Temple University School of Medicine, Philadelphia, Pennsylvania.
Nine infants undergoing modified Blalock-Taussig shunts were randomized to
both high-frequency jet ventilation (HFJV) and conventional ventilation
(CV). Vital signs, blood gases, mean airway pressure, lung mechanics,
functional residual capacity, and lung movement were compared on both modes
of ventilation keeping peak inspiratory and expiratory pressures constant.
The mean airway pressure was lower on HFJV than on CV (8.5 versus 10.9 cm
H2O). Arterial partial pressure of oxygen was greater on HFJV than on CV
(55 versus 46 mm Hg), arterial partial pressure of carbon dioxide was lower
on HFJV than on CV (28 versus 37 mm Hg), whereas compliance (0.54 versus
0.56 mL.cm H2O-1.kg- 1). resistance (110 versus 95 cm H2O/L.s), and
functional residual capacity (23 versus 22.5 mL/kg) remained the same. Lung
movement and degree of retraction necessary for surgical exposure as
evaluated by an independent observer was less with HFJV compared with CV.
Compared with CV during the creation of Blalock-Taussig shunts, HFJV
provides better gas exchange at lower mean airway pressure with similar
lung function, lung volume, and hemodynamics.