The Annals of Thoracic Surgery, Vol 57, 440-443, Copyright © 1994 by The Society of Thoracic Surgeons
CC Canver and RM Zwolak
In general, the right internal thoracic artery (ITA) is used less
frequently as a graft than the left ITA in coronary artery bypass grafting.
To determine whether there is an anatomic or hemodynamic rationale for the
underuse of the right ITA, noninvasive measurements of right and left ITAs
were performed in 171 patients before the bypass procedure. Transthoracic
visualization of both vessels was accomplished using a color-flow duplex
scanner (5.0-MHz probe) through the third intercostal space. The diameter
(in millimeters), peak systolic velocity (in centimeters per second), and
end-diastolic velocity (in centimeters per second) were measured in all but
2 patients. The mean right ITA diameter was 2.7 +/- 0.6 mm, the mean peak
systolic velocity was 100 +/- 29 cm/s, and the mean end-diastolic velocity
was 6 +/- 5 cm/s. Diameter and flow velocity measurements for the right and
left ITA were similar in all patients (p = not significant). The measured
values for both sites were independent of age and sex, or the presence of
hypertension or diabetes mellitus (p = not significant). We conclude that
no morphologic or physiologic differences exist between the right and left
ITAs. The findings from this study indicate that color-flow duplex
ultrasound imaging is a safe and reliable noninvasive technique in the
preoperative assessment of the anatomic and functional characteristics of
the right ITA before coronary artery bypass grafting.
ARTICLES
Preoperative evaluation of the right internal thoracic artery for coronary surgery
Section of Cardiothoracic Surgery, Dartmouth Medical School, Dartmouth- Hitchcock Medical Center, Lebanon, NH.
This article has been cited by other articles:
![]() |
C. C. Canver, V. M. Armstrong, S. D. Cooler, and R. D. Nichols Assessment of Internal Thoracic Artery Vasoreactivity in Response to Sublingual Nitroglycerin Ann. Thorac. Surg., April 1, 1997; 63(4): 1041 - 1043. [Abstract] [Full Text] |
||||
![]() |
C. C. Canver, V. M. Armstrong, R. D. Nichols, and R. M. Mentzer Jr Color-Flow Duplex Ultrasound Assessment of Internal Thoracic Artery Graft After Coronary Bypass Ann. Thorac. Surg., February 1, 1995; 59(2): 389 - 392. [Abstract] [Full Text] |
||||