Ann Thorac Surg 1994;57:237-238
© 1994 The Society of Thoracic Surgeons
Department of Surgery, Sakakibara Heart Institute, Tokyo, Japan
Accepted for publication August 18, 1993.
* Address reprint requests to Dr Kasegawa, Sakakibara Heart Institute. 2-5-4 Yoyogi Shibuya-ku, Tokyo, Japan.
A simple method for determining the length of artificial chordae in mitral reconstructive operations is described. A small tourniquet is used for fine adjustment of the length of polytetrafluoroethylene stitches before tying them during leaking test. We have used this technique in 10 consecutive patients with anterior mitral leaflet prolapse since August 1992. Intraoperative transesophageal echocardiography revealed no or only trace mitral regurgitation after valve repair in all cases. This method minimized the time of determining the proper length of artificial chordae and achieved good results.
This article has been cited by other articles:
![]() |
Y. Matsui, S. Kubota, H. Sugiki, S. Wakasa, T. Ooka, T. Tachibana, and S. Sasaki Measured Tube Technique for Ensuring the Correct Length of Slippery Artificial Chordae in Mitral Valvuloplasty Ann. Thorac. Surg., September 1, 2011; 92(3): 1132 - 1134. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. A. Radermecker Adjusting the Length of Goretex Artificial Chordae Ann. Thorac. Surg., January 1, 2010; 89(1): 344 - 345. [Full Text] [PDF] |
||||
![]() |
A. Doi, H. Iida, and T. Sunazawa Intracardiac Calipers for Artificial Chordae Replacement in Mitral Valve Repair Ann. Thorac. Surg., January 1, 2009; 87(1): 326 - 328. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Nonaka, A. Marui, M. Fukuoka, T. Shimamoto, S. Masuyama, T. Ikeda, and M. Komeda Differences in mitral valve-left ventricle dimensions between a beating heart and during saline injection test Eur J Cardiothorac Surg, October 1, 2008; 34(4): 755 - 759. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Morimoto, K. Tsuchiya, M. Nakajima, Y. Mitsumori, and K. Kato Chordal Replacement with Temporary Alfieri Stitch for Anterior Leaflet Prolapse Asian Cardiovasc Thorac Ann, December 1, 2007; 15(6): 531 - 533. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Maselli, R. De Paulis, L. Weltert, A. Salica, R. Scaffa, A. Bellisario, and A. Mingiano A new method for artificial chordae length "tuning" in mitral valve repair: Preliminary experience J. Thorac. Cardiovasc. Surg., August 1, 2007; 134(2): 454 - 459. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Kasegawa, T. Shimokawa, I. Shibazaki, H. Hayashi, T. Koyanagi, and T. Ida Mitral valve repair for anterior leaflet prolapse with expanded polytetrafluoroethylene sutures. Ann. Thorac. Surg., May 1, 2006; 81(5): 1625 - 1631. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Eguchi, E. Ohtaki, T. Matsumura, K. Tanaka, T. Tohbaru, N. Iguchi, K. Misu, R. Asano, M. Nagayama, T. Sumiyoshi, et al. Pre-operative atrial fibrillation as the key determinant of outcome of mitral valve repair for degenerative mitral regurgitation Eur. Heart J., September 2, 2005; 26(18): 1866 - 1872. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Bando, H. Kasegawa, Y. Okada, J. Kobayashi, A. Kada, T. Shimokawa, M. Nasu, S. Nakatani, K. Niwaya, O. Tagusari, et al. Impact of preoperative and postoperative atrial fibrillation on outcome after mitral valvuloplasty for nonischemic mitral regurgitation J. Thorac. Cardiovasc. Surg., May 1, 2005; 129(5): 1032 - 1040. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Matsui, Y. Fukada, Y. Naito, S. Sasaki, and K. Yasuda A New Device for Ensuring the Correct Length of Artificial Chordae in Mitral Valvuloplasty Ann. Thorac. Surg., March 1, 2005; 79(3): 1064 - 1065. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Matsumura, E. Ohtaki, K. Tanaka, K. Misu, T. Tobaru, R. Asano, M. Nagayama, K. Kitahara, J. Umemura, T. Sumiyoshi, et al. Echocardiographic prediction ofleft ventricular dysfunction aftermitral valve repair for mitral regurgitation as anindicator to decide the optimal timing of repair J. Am. Coll. Cardiol., August 6, 2003; 42(3): 458 - 463. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. H. Adams, A. Kadner, and R. H. Chen Artificial mitral valve chordae replacement made simple Ann. Thorac. Surg., April 1, 2001; 71(4): 1377 - 1378. [Abstract] [Full Text] [PDF] |
||||
![]() |
U. O. von Oppell and F. W. Mohr Chordal replacement for both minimally invasive and conventional mitral valve surgery using premeasured Gore-Tex loops Ann. Thorac. Surg., December 1, 2000; 70(6): 2166 - 2168. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Matsumoto, H. Kado, M. Masuda, Y. Shiokawa, K. Fukae, S. Morita, and H. Yasui CLINICAL RESULTS OF MITRAL VALVE REPAIR BY RECONSTRUCTING ARTIFICIAL CHORDAE TENDINEAE IN CHILDREN J. Thorac. Cardiovasc. Surg., July 1, 1999; 118(1): 94 - 98. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |