ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Redmond, J. M.
Right arrow Articles by Baumgartner, W. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Redmond, J. M.
Right arrow Articles by Baumgartner, W. A.

The Annals of Thoracic Surgery, Vol 56, 474-478, Copyright © 1993 by The Society of Thoracic Surgeons


ARTICLES

Heparin-coated bypass circuits reduce pulmonary injury

JM Redmond, AM Gillinov, RS Stuart, KJ Zehr, JA Winkelstein, A Herskowitz, DE Cameron and WA Baumgartner
Department of Cardiac Surgery, Johns Hopkins Medical Institutions, Baltimore, Maryland 21205.

Heparin coating of the extracorporeal circuit not only reduces heparin requirements during cardiac operations but also may reduce organ injury associated with cardiopulmonary bypass (CPB). To examine this possibility, pulmonary injury and neutrophil adhesion molecule expression after CPB were studied in pigs undergoing CPB with a standard extracorporeal circuit (group S, n = 6) or a heparin-coated CPB circuit (Carmeda BioActive Surface) (group HC, n = 6). Pigs received heparin sodium (300 U/kg intravenously) and then underwent 90 minutes of hypothermic (28 degrees C) CPB using membrane oxygenators, followed by 2 hours of observation. Blood samples were obtained for determination of neutrophil number and expression of the neutrophil adhesion molecule subunit CD18 (by immunofluorescence flow cytometry). The CPB-associated injury was less in group HC. Two hours after CPB, the arterial oxygen tension group was higher in group HC (597.2 +/- 31.2 versus 220.5 +/- 42.3 mm Hg; p < 0.0001), the pulmonary vascular resistance was lower in these animals (408.6 +/- 69.4 versus 1,159.8 +/- 202.4 dyne.s.cm-5; p = 0.02), and the static compliance was higher in group HC (66.4 +/- 5.4 versus 39.8 +/- 5.8 mL/mm Hg; p = 0.004). After 60 minutes of CPB, both groups had similar increases in expression of the neutrophil adhesion molecule subunit CD18 (29.4% +/- 19.5% versus 26.0% +/- 24.4%, group S and group HC, respectively) and similar decreases in neutrophil counts (6,056 +/- 1,285 to 2,453 +/- 979 cells/microL versus 6,010 +/- 1,748 to 3,197 +/- 1,225 cells/microL, group S and group HC, respectively).(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
Anesth. Analg.Home page
G. S. Murphy, E. A. Hessel II, and R. C. Groom
Optimal Perfusion During Cardiopulmonary Bypass: An Evidence-Based Approach
Anesth. Analg., May 1, 2009; 108(5): 1394 - 1417.
[Abstract] [Full Text] [PDF]


Home page
Asian Cardiovasc. Thorac. Ann.Home page
E. M. Carvalho, E. A Gabriel, and T. A Salerno
Pulmonary Protection During Cardiac Surgery: Systematic Literature Review
Asian Cardiovasc Thorac Ann, December 1, 2008; 16(6): 503 - 507.
[Abstract] [Full Text] [PDF]


Home page
Card Surg AdultHome page
E. C. McGee Jr., P. M. McCarthy, and N. Moazami
Temporary Mechanical Circulatory Support
Card. Surg. Adult, January 1, 2008; 3(2008): 507 - 534.
[Full Text]


Home page
Card Surg AdultHome page
D. R. Brinster, R. J. Rizzo, and R. M. Bolman III
Ascending Aortic Aneurysms
Card. Surg. Adult, January 1, 2008; 3(2008): 1223 - 1250.
[Full Text]


Home page
Ann. Thorac. Surg.Home page
The Society of Thoracic Surgeons Blood Conservatio, V. A. Ferraris, S. P. Ferraris, S. P. Saha, E. A. Hessel II, C. K. Haan, B. D. Royston, C. R. Bridges, R. S.D. Higgins, G. Despotis, et al.
Perioperative Blood Transfusion and Blood Conservation in Cardiac Surgery: The Society of Thoracic Surgeons and The Society of Cardiovascular Anesthesiologists Clinical Practice Guideline
Ann. Thorac. Surg., May 1, 2007; 83(5_Supplement): S27 - S86.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
E. Khoshbin, A. E. Dux, H. Killer, A. W Sosnowski, R. K Firmin, and G. J Peek
A comparison of radiographic signs of pulmonary inflammation during ECMO between silicon and poly-methyl pentene oxygenators
Perfusion, January 1, 2007; 22(1): 15 - 21.
[Abstract] [PDF]


Home page
Anesth. Analg.Home page
M. E. Jessen
Pro: Heparin-Coated Circuits Should be Used for Cardiopulmonary Bypass
Anesth. Analg., December 1, 2006; 103(6): 1365 - 1369.
[Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
Y. Yang, J. Cai, S. Wang, H. Zhang, J. Liu, Z. Xu, and Z. Su
Better protection of pulmonary surfactant integrity with deep hypothermia and circulatory arrest.
Ann. Thorac. Surg., July 1, 2006; 82(1): 131 - 136.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
E. Khoshbin, C. Westrope, S. Pooboni, D. Machin, H. Killer, G. J Peek, A. W Sosnowski, and R. K Firmin
Performance of polymethyl pentene oxygenators for neonatal extracorporeal membrane oxygenation: a comparison with silicone membrane oxygenators
Perfusion, May 1, 2005; 20(3): 129 - 134.
[Abstract] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
J. M. Dodd-o, L. E. Welsh, J. D. Salazar, P. L. Walinsky, E. A. Peck, J. G. Shake, D. J. Caparrelli, R. C. Ziegelstein, J. L. Zweier, W. A. Baumgartner, et al.
Effect of NADPH oxidase inhibition on cardiopulmonary bypass-induced lung injury
Am J Physiol Heart Circ Physiol, August 1, 2004; 287(2): H927 - H936.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
R. de Vroege, W. van Oeveren, J. van Klarenbosch, W. Stooker, M. A. J. M. Huybregts, C. E. Hack, L. van Barneveld, L. Eijsman, and C. R. H. Wildevuur
The Impact of Heparin-Coated Cardiopulmonary Bypass Circuits on Pulmonary Function and the Release of Inflammatory Mediators
Anesth. Analg., June 1, 2004; 98(6): 1586 - 1594.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
J. M. Dodd-o, L. E. Welsh, J. D. Salazar, P. L. Walinsky, E. A. Peck, J. G. Shake, D. J. Caparrelli, B. T. Bethea, S. M. Cattaneo, W. A. Baumgartner, et al.
Effect of bronchial artery blood flow on cardiopulmonary bypass-induced lung injury
Am J Physiol Heart Circ Physiol, February 1, 2004; 286(2): H693 - H700.
[Abstract] [Full Text] [PDF]


Home page
Card Surg AdultHome page
N. Moazami and P. M. McCarthy
Temporary Circulatory Support
Card. Surg. Adult, January 1, 2003; 2(2003): 495 - 520.
[Full Text]


Home page
Card Surg AdultHome page
C. A. Anderson, R. J. Rizzo, and L. H. Cohn
Ascending Aortic Aneurysms
Card. Surg. Adult, January 1, 2003; 2(2003): 1123 - 1148.
[Full Text]


Home page
PerfusionHome page
H. I Flom-Halvorsen, E Ovrum, F Brosstad, G Tangen, M A. Ringdal, and R Oystese
Effects of two differently heparin-coated extracorporeal circuits on markers for brain and myocardial dysfunction
Perfusion, September 1, 2002; 17(5): 339 - 345.
[Abstract] [PDF]


Home page
ChestHome page
C. S.H. Ng, S. Wan, A. P.C. Yim, and A. A. Arifi
Pulmonary Dysfunction After Cardiac Surgery*
Chest, April 1, 2002; 121(4): 1269 - 1277.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
K McCusker, V Vijay, W DeBois, R Helm, and D Sisto
MAST system: a new condensed cardiopulmonary bypass circuit for adult cardiac surgery
Perfusion, December 1, 2001; 16(6): 447 - 452.
[Abstract] [PDF]


Home page
SEMIN CARDIOTHORAC VASC ANESTHHome page
G. E. Hill
The Inflammatory Response to Cardiopulmonary Bypass-- Should It Be Treated?
Seminars in Cardiothoracic and Vascular Anesthesia, September 1, 2001; 5(3): 229 - 235.
[Abstract] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
E. Ovrum, G. Tangen, R. Oystese, M. A. L. Ringdal, and R. Istad
Comparison of two heparin-coated extracorporeal circuits with reduced systemic anticoagulation in routine coronary artery bypass operations
J. Thorac. Cardiovasc. Surg., February 1, 2001; 121(2): 0324 - 330.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
J. P. Gott
Leukodepletion and aprotinin improve clinical outcome after extracorporeal circulation
Perfusion, January 1, 2001; 16(1_suppl): 5 - 9.
[Abstract] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
A. Belboul, C. Lofgren, C. Storm, and M. Jungbeck
Heparin-coated circuits reduce occult myocardial damage during CPB: a randomized, single blind clinical trial
Eur. J. Cardiothorac. Surg., May 1, 2000; 17(5): 580 - 586.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
T. Ozawa, K. Yoshihara, N. Koyama, Y. Watanabe, N. Shiono, and Y. Takanashi
Clinical efficacy of heparin-bonded bypass circuits related to cytokine responses in children
Ann. Thorac. Surg., February 1, 2000; 69(2): 584 - 590.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
D. F Larson, D. Arzouman, L. Kleinert, V. Patula, and S. Williams
Comparison of Sarns 3M heparin bonded to Duraflo II and control circuits in a porcine model: macro- and microanalysis of thrombi accumulation in circuit arterial filters
Perfusion, January 1, 2000; 15(1): 13 - 20.
[Abstract] [PDF]


Home page
J Am Coll CardiolHome page
K. A. Eagle, R. A. Guyton, R. Davidoff, G. A. Ewy, J. Fonger, T. J. Gardner, J. P. Gott, H. C. Herrmann, R. A. Marlow, W. C. Nugent, et al.
ACC/AHA guidelines for coronary artery bypass graft surgery: A report of the American College of Cardiology/ American Heart Association task force on Practice Guidelines (Committee to revise the 1991 Guidelines for Coronary Artery Bypass Graft Surgery)
J. Am. Coll. Cardiol., October 1, 1999; 34(4): 1262 - 1347.
[Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
H. Kumano, S. Suehiro, K. Hattori, T. Shibata, Y. Sasaki, M. Hosono, and H. Kinoshita
Coagulofibrinolysis during heparin-coated cardiopulmonary bypass with reduced heparinization
Ann. Thorac. Surg., October 1, 1999; 68(4): 1252 - 1256.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
G. Asimakopoulos, P. L.C. Smith, C. P. Ratnatunga, and K. M. Taylor
Lung injury and acute respiratory distress syndrome after cardiopulmonary bypass
Ann. Thorac. Surg., September 1, 1999; 68(3): 1107 - 1115.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
C. B. Mahoney and G. M. Lemole
Transfusion after coronary artery bypass surgery: the impact of heparin-bonded circuits
Eur. J. Cardiothorac. Surg., August 1, 1999; 16(2): 206 - 210.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
G. Asimakopoulos
Mechanisms of the systemic inflammatory response
Perfusion, July 1, 1999; 14(4): 269 - 277.
[PDF]


Home page
Ann. Thorac. Surg.Home page
H. Watanabe, J.-i. Hayashi, H. Ohzeki, H. Moro, M. Sugawara, and S. Eguchi
Biocompatibility of a silicone-coated polypropylene hollow fiber oxygenator in an in vitro model
Ann. Thorac. Surg., May 1, 1999; 67(5): 1315 - 1319.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
A. L. Picone, C. J. Lutz, C. Finck, D. Carney, L. A. Gatto, A. Paskanik, B. Searles, K. Snyder, and G. Nieman
Multiple sequential insults cause post-pump syndrome
Ann. Thorac. Surg., April 1, 1999; 67(4): 978 - 985.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. Ranucci, A. Mazzucco, R. Pessotto, G. Grillone, V. Casati, L. Porreca, R. Maugeri, M. Meli, P. Magagna, S. Cirri, et al.
Heparin-coated circuits for high-risk patients: a multicenter, prospective, randomized trial
Ann. Thorac. Surg., April 1, 1999; 67(4): 994 - 1000.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
A. J. Lodge, P. J. Chai, C. W. Daggett, R. M. Ungerleider, and J. Jaggers
METHYLPREDNISOLONE REDUCES THE INFLAMMATORY RESPONSE TO CARDIOPULMONARY BYPASS IN NEONATAL PIGLETS: TIMING OF DOSE IS IMPORTANT
J. Thorac. Cardiovasc. Surg., March 1, 1999; 117(3): 515 - 522.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
G. Asimakopoulos and K. M. Taylor
Effects of cardiopulmonary bypass on leukocyte and endothelial adhesion molecules
Ann. Thorac. Surg., December 1, 1998; 66(6): 2135 - 2144.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. P. Gott, W. A. Cooper, F. E. Schmidt Jr, W. M. Brown III, C. E. Wright, J. D. Merlino, J. D. Fortenberry, W. S. Clark, and R. A. Guyton
Modifying risk for extracorporeal circulation: trial of four antiinflammatory strategies
Ann. Thorac. Surg., September 1, 1998; 66(3): 747 - 754.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
G. S. Aldea, P. O'Gara, O. M. Shapira, P. Treanor, A. Osman, E. Patalis, C. Arkin, R. Diamond, V. Babikian, H. L. Lazar, et al.
Effect of Anticoagulation Protocol on Outcome in Patients Undergoing CABG With Heparin-Bonded Cardiopulmonary Bypass Circuits
Ann. Thorac. Surg., February 1, 1998; 65(2): 425 - 433.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
L. S Shekerdemian, A. Bush, C. Lincoln, D. F Shore, A. J Petros, and A. N Redington
Cardiopulmonary interactions in healthy children and children after simple cardiac surgery: the effects of positive and negative pressure ventilation
Heart, December 1, 1997; 78(6): 587 - 593.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
M Ranucci, G Soro, A Frigiola, L Menicanti, A Ditta, G Candido, and S Tambalo
Normothermic perfusion and lung function after cardiopulmonary bypass: effects in pulmonary risk patients
Perfusion, September 1, 1997; 12(5): 309 - 315.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
H. L. Lazar, X. Zhang, T. Hamasaki, C. A. Memmelo, P. Treanor, S. Rivers, G. S. Aldea, S. A. Bernard, and R. J. Shemin
Heparin-Bonded Circuits Decrease Myocardial Ischemic Damage: An Experimental Study
Ann. Thorac. Surg., June 1, 1997; 63(6): 1701 - 1705.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
O. Moen, K. Hogasen, E. Fosse, E. Dregelid, V. Brockmeier, P. Venge, M. Harboe, and T. E. Mollnes
Attenuation of Changes in Leukocyte Surface Markers and Complement Activation With Heparin-Coated Cardiopulmonary Bypass
Ann. Thorac. Surg., January 1, 1997; 63(1): 105 - 111.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
E. Ovrum, E. A. Holen, G. Tangen, and M.-A. L. Ringdal
Heparinized Cardiopulmonary Bypass and Full Heparin Dose Marginally Improve Clinical Performance
Ann. Thorac. Surg., October 1, 1996; 62(4): 1128 - 1133.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
G. S. Aldea, M. Doursounian, P. O'Gara, P. Treanor, O. M. Shapira, H. L. Lazar, and R. J. Shemin
Heparin-Bonded Circuits With a Reduced Anticoagulation Protocol in Primary CABG: A Prospective, Randomized Study
Ann. Thorac. Surg., August 1, 1996; 62(2): 410 - 418.
[Abstract] [Full Text]


Home page
PerfusionHome page
S. Daniel
Review on the multifactorial aspects of bioincompatibility in CPB
Perfusion, May 1, 1996; 11(3): 246 - 255.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. Ranucci, S. Cirri, D. Conti, A. Ditta, A. Boncilli, A. Frigiola, and L. Menicanti
Beneficial Effects of Duraflo II Heparin-Coated Circuits on Postperfusion Lung Dysfunction
Ann. Thorac. Surg., January 1, 1996; 61(1): 76 - 81.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
E. Ovrum, T. E. Mollnes, E. Fosse, E. A. Holen, G. Tangen, M. Abdelnoor, M.-A. L. Ringdal, R. Oystese, and P. Venge
COMPLEMENT AND GRANULOCYTE ACTIVATION IN TWO DIFFERENT TYPES OF HEPARINIZED EXTRACORPOREAL CIRCUITS
J. Thorac. Cardiovasc. Surg., December 1, 1995; 110(6): 1623 - 1632.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
P. W. Weerwind, J. G. Maessen, L. J. H. van Tits, R. K. Stad, E. J. Fransen, D. S. de Jong, and O. C. K. M. Penn
INFLUENCE OF DURAFLO II HEPARIN-TREATED EXTRACORPOREAL CIRCUITS ON THE SYSTEMIC INFLAMMATORY RESPONSE IN PATIENTS HAVING CORONARY BYPASS
J. Thorac. Cardiovasc. Surg., December 1, 1995; 110(6): 1633 - 1641.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
D. D. Muehrcke, P. M. McCarthy, R. W. Stewart, S. Seshagiri, D. A. Ogella, R. C. Foster, and D. M. Cosgrove
Complications of extracorporeal life support systems using heparin-bound surfaces: The risk of intracardiac clot formation
J. Thorac. Cardiovasc. Surg., September 1, 1995; 110(3): 843 - 851.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1993 by The Society of Thoracic Surgeons.