Deleterious effects of cardiopulmonary bypass (CPB) are partly sequelae of blood-foreign surface reactions. Coating the inner surfaces of CPB sets with heparin has been shown to decrease activation of humoral cascade systems. The aim of this study was to investigate whether the heparin-coated CPB sets influence adhesion of blood cells to surfaces of arterial filters during CPB. Thirty-one patients undergoing coronary artery bypass grafting were studied. In the control group (C) standard CPB sets and standard doses of heparin (300 IU/kg) were employed; in the HC (heparin-coated) group, heparin-coated CPB sets and reduced heparin doses (range, 150 to 225 IU/kg) were used. Two additional groups were also studied; group FC (coated filter), with standard CPB sets and heparin-coated arterial filters (heparin dose, 300 IU/kg), and group OC (uncoated filter), with heparin-scoated CPB sets and standard arterial filters (heparin dose, 300 IU/kg). The inner surfaces of the arterial filters were examined after CPB with scanning electron microscopy. Scanning electron microscopy demonstrated almost clean surfaces in heparin-coated filters even when other parts of the circuit were uncoated. Using an arbitrary adhesion score, significant differences between the groups were noted in the adhesion grade; it was lowest in group HC (2.2 ± 0.27 [mean ± standard error of the mean]) versus group C (5.4 ± 0.53; p < 0.001). In group FC it was marginally higher than in group HC but almost significantly lower than in group OC (2.6 ± 0.68 versus 5.4 ± 0.81; p = 0.05). We conclude that heparin coating of arterial filters diminishes cellular adhesion to the filter surface during CPB. This effect seems to be independent of surface characteristics in other parts of the circuit.
This article has been cited by other articles:
![]() |
The Society of Thoracic Surgeons Blood Conservatio, V. A. Ferraris, S. P. Ferraris, S. P. Saha, E. A. Hessel II, C. K. Haan, B. D. Royston, C. R. Bridges, R. S.D. Higgins, G. Despotis, et al. Perioperative Blood Transfusion and Blood Conservation in Cardiac Surgery: The Society of Thoracic Surgeons and The Society of Cardiovascular Anesthesiologists Clinical Practice Guideline Ann. Thorac. Surg., May 1, 2007; 83(5_Supplement): S27 - S86. [Abstract] [Full Text] [PDF] |
||||
![]() |
D C Whitaker, J A Stygall, S P Newman, and M J. Harrison The use of leucocyte-depleting and conventional arterial line filters in cardiac surgery: a systematic review of clinical studies Perfusion, December 1, 2001; 16(6): 433 - 446. [Abstract] [PDF] |
||||
![]() |
L B Mongero, J R Beck, H E Manspeizer, E J Heyer, K Lee, T A Spanier, and C R Smith Cardiac surgical patients exposed to heparin-bonded circuits develop less postoperative cerebral dysfunction than patients exposed to non-heparin-bonded circuits Perfusion, March 1, 2001; 16(2): 107 - 111. [Abstract] [PDF] |
||||
![]() |
T. Nakajima, K. Kawazoe, K. Ishibashi, Y. Kubota, T. Sasaki, H. Izumoto, and T. Nitatori Reduction of heparin dose is not beneficial to platelet function Ann. Thorac. Surg., July 1, 2000; 70(1): 186 - 190. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. L. Lazar, Y. Bao, S. Rivers, P. R. Treanor, and R. J. Shemin Decreased incidence of arterial thrombosis using heparin-bonded intraaortic balloons Ann. Thorac. Surg., February 1, 1999; 67(2): 446 - 449. [Abstract] [Full Text] [PDF] |
||||
![]() |
C B. Mahoney Heparin-bonded circuits: clinical outcomes and costs Perfusion, May 1, 1998; 13(3): 192 - 204. [Abstract] [PDF] |
||||
![]() |
S. Svenmarker, S. Haggmark, E. Jansson, R. Lindholm, M. Appelblad, and T. Aberg The relative safety of an oxygenator Perfusion, September 1, 1997; 12(5): 289 - 292. [Abstract] [PDF] |
||||
![]() |
H. L. Lazar, X. Zhang, T. Hamasaki, C. A. Memmelo, P. Treanor, S. Rivers, G. S. Aldea, S. A. Bernard, and R. J. Shemin Heparin-Bonded Circuits Decrease Myocardial Ischemic Damage: An Experimental Study Ann. Thorac. Surg., June 1, 1997; 63(6): 1701 - 1705. [Abstract] [Full Text] |
||||
![]() |
A. H. Kuitunen, L. J. Heikkila, and M. T. Salmenpera Cardiopulmonary Bypass With Heparin-Coated Circuits and Reduced Systemic Anticoagulation Ann. Thorac. Surg., February 1, 1997; 63(2): 438 - 444. [Abstract] [Full Text] |
||||
![]() |
H E Hogevold, O Moen, E Fosse, P Venge, J Braten, C Andersson, and T Lyberg Effects of heparin coating on the expression of CD11b, CD11c and CD62L by leucocytes in extracorporeal circulation in vitro Perfusion, January 1, 1997; 12(1): 9 - 20. [Abstract] [PDF] |
||||
![]() |
G. S. Aldea, M. Doursounian, P. O'Gara, P. Treanor, O. M. Shapira, H. L. Lazar, and R. J. Shemin Heparin-Bonded Circuits With a Reduced Anticoagulation Protocol in Primary CABG: A Prospective, Randomized Study Ann. Thorac. Surg., August 1, 1996; 62(2): 410 - 418. [Abstract] [Full Text] |
||||
![]() |
D. D. Muehrcke, P. M. McCarthy, K. Kottke-Marchant, H. Harasaki, J. Pierre-Yared, J. A. Borsh, D. A. Ogella, and D. M. Cosgrove BIOCOMPATIBILITY OF HEPARIN-COATED EXTRACORPOREAL BYPASS CIRCUITS: A RANDOMIZED, MASKED CLINICAL TRIAL J. Thorac. Cardiovasc. Surg., August 1, 1996; 112(2): 472 - 483. [Abstract] [Full Text] |
||||
![]() |
D. Royston Surgery with cardiopulmonary bypass and pulmonary inflammatory responses Perfusion, May 1, 1996; 11(3): 213 - 219. [PDF] |
||||
![]() |
S. Daniel Review on the multifactorial aspects of bioincompatibility in CPB Perfusion, May 1, 1996; 11(3): 246 - 255. [Abstract] [PDF] |
||||
![]() |
D. D. Muehrcke, P. M. McCarthy, R. W. Stewart, R. C. Foster, D. A. Ogella, J. A. Borsh, and D. M. Cosgrove III Extracorporeal Membrane Oxygenation for Postcardiotomy Cardiogenic Shock Ann. Thorac. Surg., February 1, 1996; 61(2): 684 - 691. [Abstract] [Full Text] |
||||
![]() |
L. K. v. Segesser, B. M. Weiss, M. Pasic, E. Garcia, and M. I. Turina Risk and benefit of low systemic heparinization during open heart operations Ann. Thorac. Surg., August 1, 1994; 58(2): 391 - 398. [Abstract] [PDF] |
||||
![]() |
D. R. Jones, R. C. Hill, A. Vasilakis, M. J. Hollingsed, G. M. Graeber, R. A. Gustafson, J. L. Cruzzavala, and G. F. Murray Safe use of heparin-coated bypass circuits incorporating a pump-oxygenator Ann. Thorac. Surg., April 1, 1994; 57(4): 815 - 819. [Abstract] [PDF] |
||||