The Annals of Thoracic Surgery, Vol 55, 1027-1029, Copyright © 1993 by The Society of Thoracic Surgeons
JG Copeland 3d, LJ Rosado and SL Snyder
By using both aortic annular and supraannular aortic wall tandem suture
lines, we have, in our experience, markedly improved hemostasis in aortic
root replacement with composite conduits of two types. Using this
technique, 4 of 5 patients required 2 units or less of transfused red blood
cells. Two patients did not receive transfusions. The technique consists of
using interrupted mattress sutures to anchor the lower part of the valve
sewing ring to the aortic annulus. The upper part of the sewing ring is
then anchored with a running suture line to the cut edge of the
supraannular aortic wall.
ARTICLES
New technique for improving hemostasis in aortic root replacement with composite graft
Department of Cardiovascular and Thoracic Surgery, University Medical Center, Tucson, Arizona 85724.
This article has been cited by other articles:
![]() |
D. Nezic, M. Cirkovic, A. Knezevic, and M. Jovic Modified Bentall procedure - 'a collar technique' to control bleeding from coronary ostia anastomoses Interactive CardioVascular and Thoracic Surgery, August 1, 2008; 7(4): 709 - 711. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Pacini, E. Villa, S. Martin-Suarez, and R. D. Bartolomeo Aortic root substitution after aortic valve replacement: a prosthesis-sparing operation Eur. J. Cardiothorac. Surg., April 1, 2005; 27(4): 717 - 719. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. P Urbanski, W. Dinstak, S. Frank, A. Siebel, and R. W Hacker Modified versus Standard Mechanical Valved Aortic Conduit Asian Cardiovasc Thorac Ann, March 1, 2005; 13(1): 53 - 57. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. A. LeMaire INVITED COMMENTARY Ann. Thorac. Surg., January 1, 2005; 79(1): 152 - 152. [Full Text] [PDF] |
||||
![]() |
M. Turina Composite graft replacement of the aortic root: 'button' technique MMCTS, December 4, 2003; 2003(1204): MMCTS.2003.000001. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. D. Milano, S. Pratali, G. Mecozzi, P. Boraschi, G. Braccini, E. Magagnini, and U. Bortolotti Fate of coronary ostial anastomoses after the modified Bentall procedure Ann. Thorac. Surg., June 1, 2003; 75(6): 1797 - 1801. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Pibarot and J. G. Dumesnil Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention J. Am. Coll. Cardiol., October 1, 2000; 36(4): 1131 - 1141. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. K Srivastava, S. Pandey, A. Kapoor, A. K Srivastava, S. Pandey, and A. Kapoor Pericardial Reinforcement for Hemostasis in Aortic Aneurysm Surgery Asian Cardiovasc Thorac Ann, March 1, 2000; 8(1): 70 - 72. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. A. Browdie and R. V. Bernstein Aortic root hemorrhage and presealed composite grafts with porous sewing cuffs Ann. Thorac. Surg., August 1, 1998; 66(2): 609 - 609. [Full Text] [PDF] |
||||
![]() |
J. G. Copeland Reply Ann. Thorac. Surg., August 1, 1998; 66(2): 609 - 609. [Full Text] [PDF] |
||||
![]() |
A. D. Hilgenberg, C. W. Akins, D. L. Logan, G. J. Vlahakes, M. J. Buckley, J. C. Madsen, and D. F. Torchiana Composite Aortic Root Replacement With Direct Coronary Artery Implantation Ann. Thorac. Surg., October 1, 1996; 62(4): 1090 - 1095. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |