Ann Thorac Surg 1992;54:582-583
© 1992 The Society of Thoracic Surgeons
Norfolk, Virginia USA
Accepted for publication May 11, 1992.
* Address reprint requests to Dr Szentpetery, 400 West Brambleton Ave, Suite 200, Norfolk, VA 23510-1193.
An alternative technique of handling the aortic cannulation site blowout is described. The cannulation site is excluded with a side-biting clamp. The area is excised. Pericardial patch is sewn in to cover the defect.