|
|
||||||||
Ann Thorac Surg 1992;53:706-708
© 1992 The Society of Thoracic Surgeons
Divisions of Cardiothoracic Anesthesiology and Surgery, Washington University School of Medicine, St. Louis, Missouri, USA
Accepted for publication September 27, 1991.
* Address reprint requests to Dr Heerdt, Department of Anesthesiology Washington University School of Medicine, 660 South Euclid, Box 8054, St. Louis, MO 63110.
We have been comparing cardiac output measured with a novel Doppler pulmonary artery catheter to that measured by thermodilution and aortic electromagnetometry in cardiac surgical patients. We report here our observation of a nearly twofold increase in thermodilution cardiac output after the acute intraoperative onset of tricuspid regurgitation that was not confirmed by the novel catheter or direct measurement of aortic blood flow. We conclude that in some patients, acute tricuspid regurgitation may lessen the reliability of thermodilution cardiac output.
This article has been cited by other articles:
![]() |
A. Dahiya, W. Vollbon, C. Jellis, D. Prior, S. Wahi, and T. Marwick Echocardiographic assessment of raised pulmonary vascular resistance: application to diagnosis and follow-up of pulmonary hypertension Heart, December 15, 2010; 96(24): 2005 - 2009. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. A. Reuter, C. Huang, T. Edrich, S. K. Shernan, and H. K. Eltzschig Cardiac Output Monitoring Using Indicator-Dilution Techniques: Basics, Limits, and Perspectives Anesth. Analg., March 1, 2010; 110(3): 799 - 811. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. W. Buffington and E. U. M. Nystrom Neither the Accuracy nor the Precision of Thermal Dilution Cardiac Output Measurements Is Altered by Acute Tricuspid Regurgitation in Pigs Anesth. Analg., April 1, 2004; 98(4): 884 - 890. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. M. HOEPER, R. MAIER, J. TONGERS, J. NIEDERMEYER, J. M. HOHLFELD, M. HAMM, and H. FABEL Determination of Cardiac Output by the Fick Method, Thermodilution, and Acetylene Rebreathing in Pulmonary Hypertension Am. J. Respir. Crit. Care Med., August 1, 1999; 160(2): 535 - 541. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. M. Heerdt, C. G. Pond, G. A. Blessios, and M. Rosenbloom Comparison of cardiac output measured by intrapulmonary artery doppler, thermodilution, and electromagnetometry Ann. Thorac. Surg., November 1, 1992; 54(5): 959 - 966. [Abstract] [PDF] |
||||
![]() |
E. A Hessel II Review article : What's new in monitoring the coronary surgery patient? Perfusion, July 1, 1992; 7(3): 161 - 194. [Abstract] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |