ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Phillips, S. J.
Right arrow Articles by Kongtahworn, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Phillips, S. J.
Right arrow Articles by Kongtahworn, C.

The Annals of Thoracic Surgery, Vol 53, 162-162, Copyright © 1992 by The Society of Thoracic Surgeons


ARTICLES

Sheathless insertion of the percutaneous intraaortic balloon pump: an alternate method

SJ Phillips, M Tannenbaum, RH Zeff, LA Iannone, M Ghali and C Kongtahworn
Mercy Hospital Medical Center, Des Moines, IA 50314.

A technique is described that allows insertion of a standard percutaneous intraaortic balloon without use of the larger 12F sheath. Standard 9.5-cm. Percor balloons were inserted in a series of patients without using the provided sheath. Elimination of the sheath reduced the potential vascular complications related to the extra bulk placed in the femoral artery by the sheath. No serious complications were noted in more than 25 patients.


This article has been cited by other articles:


Home page
Card Surg AdultHome page
E. C. McGee Jr., P. M. McCarthy, and N. Moazami
Temporary Mechanical Circulatory Support
Card. Surg. Adult, January 1, 2008; 3(2008): 507 - 534.
[Full Text]


Home page
Ann. Thorac. Surg.Home page
T. Suzuki, M. Okabe, M. Handa, F. Yasuda, and Y. Miyake
Usefulness of preoperative intraaortic balloon pump therapy during off-pump coronary artery bypass grafting in high-risk patients
Ann. Thorac. Surg., June 1, 2004; 77(6): 2056 - 2059.
[Abstract] [Full Text] [PDF]


Home page
Card Surg AdultHome page
N. Moazami and P. M. McCarthy
Temporary Circulatory Support
Card. Surg. Adult, January 1, 2003; 2(2003): 495 - 520.
[Full Text]


Home page
Ann. Thorac. Surg.Home page
C. A. Dietl, M. D. Berkheimer, E. L. Woods, C. L. Gilbert, W. F. Pharr, and C. H. Benoit
Efficacy and Cost-Effectiveness of Preoperative IABP in Patients with Ejection Fraction of 0.25 or Less
Ann. Thorac. Surg., August 1, 1996; 62(2): 401 - 409.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
F. Beyersdorf, Z. Mitrev, K. Ihnken, W. Schmiedt, K. Sarai, L. Eckel, O. Friesewinkel, G. Matheis, and G. D. Buckberg
CONTROLLED LIMB REPERFUSION IN PATIENTS HAVING CARDIAC OPERATIONS
J. Thorac. Cardiovasc. Surg., April 1, 1996; 111(4): 873 - 881.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1992 by The Society of Thoracic Surgeons.