ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Joseph S. Auteri
Valluvan Jeevanandam
Mark R. Bielefeld
Juan A. Sanchez
Henry M. Spotnitz
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Auteri, J. S.
Right arrow Articles by Spotnitz, H. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Auteri, J. S.
Right arrow Articles by Spotnitz, H. M.

Ann Thorac Surg 1991;52:1052-1057
© 1991 The Society of Thoracic Surgeons


Articles

Effect of AICD patch electrodes on the diastolic pressure-volume curve in pigs

Joseph S. Auteri, MD, Valluvan Jeevanandam, MD, Mark R. Bielefeld, MD, Juan A. Sanchez, MD, Henry M. Spotnitz, MD*

Department of Surgery, Columbia University College of Physicians and Surgeons, New York, New York USA

* Address reprint requests to Dr Spotnitz, Department of Surgery, Columbia University College of Physicians and Surgeons, 630 W 168th St, New York, NY 10032.

Although the automatic implantable cardioverter defibrillator (AICD) is effective against malignant ventricular arrhythmias, the effects of AICD patches on left ventricular diastolic properties have not been defined. Accordingly, extrapericardial (group E, n = 5) or intrapericardial (group I, n = 6) AICD patches were implanted through a median sternotomy in 11 anesthetized pigs. Six weeks later, using a left thoracotomy, the hearts were arrested with hypothermic cardioplegia. A balloon catheter was inserted into the left ventricle through the aortic root, and pressure-volume curves were measured before and after sequential removal of patches and pericardium. A dense intrapericardial fibrotic reaction in group I was not present in group E. Normalized left ventricular filling volumes in group E were significantly larger at pressures of 5.1 to 10, 15.1 to 20, and 20.1 to 28 mm Hg compared with group I (p < 0.05). We conclude that intrapericardial AICD patches adversely affect left ventricular diastolic pressure-volume relations and recommend that AICD patches be placed in the extrapericardial location clinically whenever possible.




This article has been cited by other articles:


Home page
Card Surg AdultHome page
H. M. Spotnitz
Surgical Implantation of Pacemakers and Automatic Defibrillators
Card. Surg. Adult, January 1, 2008; 3(2008): 1395 - 1428.
[Full Text]


Home page
Card Surg AdultHome page
H. M. Spotnitz
Pacemakers and Automatic Defibrillators
Card. Surg. Adult, January 1, 2003; 2(2003): 1293 - 1326.
[Full Text]


Home page
Ann. Thorac. Surg.Home page
M. M. R. Amirhamzeh, D. T. Hsu, S. E. Cabreriza, C.-X. Jia, and H. M. Spotnitz
Myocardial Edema: Comparison of Effects on Filling Volume and Stiffness of the Left Ventricle in Rats and Pigs
Ann. Thorac. Surg., May 1, 1997; 63(5): 1293 - 1297.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
M. M. R. Amirhamzeh, C.-X. Jia, J. P. Starr, R. Sciacca, N. C. Chowdhury, D. T. Hsu, and H. M. Spotnitz
Diastolic function in the heterotopic rat heart transplant model Effects of edema, ischemia, and rejection
J. Thorac. Cardiovasc. Surg., November 1, 1994; 108(5): 928 - 937.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1991 by The Society of Thoracic Surgeons.