ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kantrowitz, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kantrowitz, A.

The Annals of Thoracic Surgery, Vol 50, 672-674, Copyright © 1990 by The Society of Thoracic Surgeons


ARTICLES

Origins of intraaortic balloon pumping

A Kantrowitz
Wayne State University College of Medicine, Detroit, Michigan.

In 1968, the Journal of the American Medical Association published a paper on the "Initial clinical experience with intraaortic balloon pumping in cardiogenic shock," which gave the results of the first clinical use of the procedure developed in our laboratory. For more than 2 years, our group was the only one using intraaortic balloon pumping clinically. Later, intraaortic balloon pumping was used by others, and despite poor clinical salvage, the hemodynamic benefit was demonstrated convincingly. At the present time, approximately 70,000 balloon pump procedures are performed annually.


This article has been cited by other articles:


Home page
Card Surg AdultHome page
E. C. McGee Jr., P. M. McCarthy, and N. Moazami
Temporary Mechanical Circulatory Support
Card. Surg. Adult, January 1, 2008; 3(2008): 507 - 534.
[Full Text]


Home page
ICVTSHome page
I. Norkiene, D. Ringaitiene, K. Rucinskas, R. Samalavicius, A. Baublys, S. Miniauskas, and V. Sirvydis
Intra-aortic balloon counterpulsation in decompensated cardiomyopathy patients: bridge to transplantation or assist device
Interactive CardioVascular and Thoracic Surgery, February 1, 2007; 6(1): 66 - 70.
[Abstract] [Full Text] [PDF]


Home page
Card Surg AdultHome page
N. Moazami and P. M. McCarthy
Temporary Circulatory Support
Card. Surg. Adult, January 1, 2003; 2(2003): 495 - 520.
[Full Text]


Home page
Ann. Thorac. Surg.Home page
O. E. Arafa, O. R. Geiran, K. Andersen, E. Fosse, S. Simonsen, and J. L. Svennevig
Intraaortic balloon pumping for predominantly right ventricular failure after heart transplantation
Ann. Thorac. Surg., November 1, 2000; 70(5): 1587 - 1593.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
H. L. Lazar, Y. Bao, S. Rivers, P. R. Treanor, and R. J. Shemin
Decreased incidence of arterial thrombosis using heparin-bonded intraaortic balloons
Ann. Thorac. Surg., February 1, 1999; 67(2): 446 - 449.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
O. E. Arafa, T. H. Pedersen, J. L. Svennevig, E. Fosse, and O. R. Geiran
Intraaortic Balloon Pump in Open Heart Operations: 10-Year Follow-up With Risk Analysis
Ann. Thorac. Surg., March 1, 1998; 65(3): 741 - 747.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
D. F. Torchiana, G. Hirsch, M. J. Buckley, C. Hahn, J. W. Allyn, C. W. Akins, J. F. Drake, J. B. Newell, and W. G. Austen
INTRAAORTIC BALLOON PUMPING FOR CARDIAC SUPPORT: TRENDS IN PRACTICE AND OUTCOME, 1968 TO 1995
J. Thorac. Cardiovasc. Surg., April 1, 1997; 113(4): 758 - 769.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1990 by The Society of Thoracic Surgeons.