|
|
||||||||
Ann Thorac Surg 1989;47:167-171
© 1989 The Society of Thoracic Surgeons
Department of Cardiovascular Surgery, Pacific Presbyterian Medical Center, San Francisco, California U.S.A.
* Address reprint requests to Dr Hill, Pacific Presbyterian Medical Center, 2100 Webster St, No. 512, San Francisco, CA 94115.
Unilateral or bilateral prosthetic ventricles and artificial hearts have been used in bridging to transplantation for 4 years. Candidates for bridging to transplantation comprise patients who otherwise would be elective cardiac transplantation candidates who deteriorate rapidly before a donor heart can be found, or persons with sudden cardiac decompensation (eg, massive myocardial infarction with cardiogenic shock). In selecting patients for bridging to cardiac transplantation it is crucial that people are chosen who are good candidates for heart transplantation despite their rapidly deteriorating condition. This article compares the results of the devices available for use in this application, which include: the centrifugal pump; the Jarrik-7 orthotopic prosthetic ventricle; and the Thoratec, Novacor, and Thermedics heterotopic prosthetic ventricles.
This article has been cited by other articles:
![]() |
J P Bourke, A Loaiza, G Parry, C Hilton, S Furniss, J Dark, and J Forty Role of orthotopic heart transplantation in the management of patients with recurrent ventricular tachyarrhythmias following myocardial infarction Heart, November 1, 1998; 80(5): 473 - 478. [Abstract] [Full Text] |
||||
![]() |
D. A. Wyatt, I. L. Kron, and C. G. Tribble Use of a Dacron cuff to decrease bleeding from atrial cannulas of ventricular assist devices Ann. Thorac. Surg., May 1, 1993; 55(5): 1264 - 1265. [Abstract] [PDF] |
||||
![]() |
C. M. Burnett, J. M. Duncan, O. H. Frazier, M. S. Sweeney, J. D. Vega, and B. Radovancevic Improved multiorgan function after prolonged univentricular support Ann. Thorac. Surg., January 1, 1993; 55(1): 65 - 71. [Abstract] [PDF] |
||||
![]() |
D. J. Farrar and J. D. Hill Univentricular and biventricular thoratec VAD support as a bridge to transplantation Ann. Thorac. Surg., January 1, 1993; 55(1): 276 - 282. [Abstract] [PDF] |
||||
![]() |
S. Lick, J. G. Copeland III, R. G. Smith, M. Cleavinger, L. J. Rosado, C. L. Huston, G. K. Sethi, and T. F. Molloy Use of the Symbion biventricular assist device in bridging to transplantation Ann. Thorac. Surg., January 1, 1993; 55(1): 283 - 287. [Abstract] [PDF] |
||||
![]() |
W. S. Phillips, N. A. Burton, Q. Macmanus, and E. A. Lefrak Surgical complications in bridging to transplantation: The Thermo Cardiosystems LVAD Ann. Thorac. Surg., March 1, 1992; 53(3): 482 - 485. [Abstract] [PDF] |
||||
![]() |
J. E. Lowe, M. P. Anstadt, P. Van Trigt, P. K. Smith, P. J. Hendry, M. D. Plunkett, and G. L. Anstadt First successful bridge to cardiac transplantation using direct mechanical ventricular actuation Ann. Thorac. Surg., December 1, 1991; 52(6): 1237 - 1245. [Abstract] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |