ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Masahiro Endo
Hiroshi Nishida
Hitoshi Koyanagi
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Endo, M.
Right arrow Articles by Koyanagi, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Endo, M.
Right arrow Articles by Koyanagi, H.

Ann Thorac Surg 1988;45:568-569
© 1988 The Society of Thoracic Surgeons


Articles

Sutureless Aortic Valve Replacement for Periannular Abscess Due to Active Bacterial Endocarditis: A New Translocation Technique

Masahiro Endo, M.D.*, Hiroshi Nishida, M.D., Eisaburo Imamura, M.D., Hitoshi Koyanagi, M.D.

From the Heart Institute of Japan, Tokyo Women's Medical College, Tokyo, Japan

Accepted for publication September 29, 1987.

* Address reprint requests to Dr. Endo, Heart Institute of Japan, Tokyo Women's Medical College, 8 Kawada-cho, Shinjuku-ku, Tokyo 162, Japan

A composite valve prosthesis was prepared by direct suture of the ring prosthesis, which was separated from an intraluminal ringed graft, with a St. Jude Medical aortic valve. A new translocation method using this composite valve prosthesis was performed on a patient with aortic periannular abscess, with favorable result.




This article has been cited by other articles:


Home page
HeartHome page
S J D BRECKER, J R PEPPER, and S J EYKYN
Aortic root abscess
Heart, September 1, 1999; 82(3): 260 - 262.
[Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
I. C. Tuna, T. A. Orszulak, H. V. Schaff, and G. K. Danielson
Results of homograft aortic valve replacement for active endocarditis
Ann. Thorac. Surg., April 1, 1990; 49(4): 619 - 624.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. B. Zwischenberger, T. Z. Shalaby, and V. R. Conti
Viable Cryopreserved Aortic Homograft for Aortic Valve Endocarditis and Annular Abscesses
Ann. Thorac. Surg., September 1, 1989; 48(3): 365 - 370.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1988 by The Society of Thoracic Surgeons.