ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Masters, R. G.
Right arrow Articles by Keon, W. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Masters, R. G.
Right arrow Articles by Keon, W. J.

Ann Thorac Surg 1988;45:210-212
© 1988 The Society of Thoracic Surgeons


Articles

Extrinsic Obstruction of the Medtronic-Hall Disk Valve in the Mitral Position

R.G. Masters, M.D., F.R.C.S.C.*, W.J. Keon, M.D., F.R.C.S.C.

From the Division of Cardiothoracic Surgery, University of Ottawa Heart Institute, Ottawa, Ontario, Canada

Accepted for publication June 5, 1987.

* Address reprint requests to Dr. Masters, Division of Cardiothoracic Surgery, University of Ottawa Heart Institute, Ottawa Civic Hospital, 1053 Carling Ave, Ottawa, Ontario, Canada K1Y 4E9

Three cases of acute extrinsic obstruction of the Medtronic-Hall prosthesis in the mitral position are described. In 2 cases papillary muscle and in 1 case suture overhang caused sticking of the tilting disk against the valve rim. The mechanisms of extrinsic obstruction of the tilting disk valve, its recognition, and its prevention are discussed with a review of the literature.




This article has been cited by other articles:


Home page
Eur J Cardiothorac SurgHome page
M. Ruel, R. B. Streeter, R. de la Torre, J. R. Liddicoat, and W. E. Cohn
Intracardiac ultrasonic suture welding for knotless mitral valve replacement
Eur J Cardiothorac Surg, February 1, 2002; 21(2): 245 - 248.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
R. J. Keenan, J. M. Armitage, A. Trento, R. D. Siewers, R. L. Hardesty, H. T. Bahnson, and B. P. Griffith
Clinical experience with the Medtronic-Hall valve prosthesis
Ann. Thorac. Surg., November 1, 1990; 50(5): 748 - 753.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
G. P. Pai and J. W. Rubin
Extrinsic obstruction of the medtronic-hall disc valve in the mitral position
Ann. Thorac. Surg., March 1, 1989; 47(3): 483 - 483.
[PDF]


Home page
Ann. Thorac. Surg.Home page
S. Pories and F. P. Ittleman
Extrinsic Obstruction of the Medtronic-Hall Prosthesis
Ann. Thorac. Surg., November 1, 1988; 46(5): 601 - 602.
[PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1988 by The Society of Thoracic Surgeons.