Ann Thorac Surg 1988;45:203-205
© 1988 The Society of Thoracic Surgeons
From the Sections of Thoracic and Cardiovascular Surgery and of Surgical Pathology, Mayo Clinic and Mayo Foundation, Rochester, MN
Accepted for publication October 15, 1987.
* Address reprint requests to Dr. Trastek, Mayo Clinic, 200 First St SW, Rochester, MN 55905
The effectiveness of fibrin glue as a biological sealant for pulmonary air leaks was determined in 16 dogs. A standardized pleural defect was made in the left lower lobe, and the quantity of air passing through a chest tube was assessed with a Collins respirometer. For the 8 randomly assigned control animals, the air leak decreased over 90 minutes from a mean of 1.4 L/min to a mean of 1.1 L/min (mean decrease, 19.8%). In the 8 randomly assigned fibrin glue-treated animals, the air leak decreased from a mean of 2.1 L/min to a mean of 0.5 L/min (mean decrease, 80.8%) (p < 0.0001). Postoperative evaluation of survivors disclosed no increased adhesions in the glue-treated animals and complete resorption of the glue at 3 months. We conclude that in this animal model, fibrin glue reduced the size of pulmonary air leaks in the early period after thoracotomy and did not lead to increased intrapleural adhesions.
This article has been cited by other articles:
![]() |
A. Gonfiotti, P. F. Santini, M. Jaus, A. Janni, A. Lococo, A. R. De Massimi, A. D'Agostino, F. Carleo, M. Di Martino, V. Larocca, et al. Safety and Effectiveness of a New Fibrin Pleural Air Leak Sealant: A Multicenter, Controlled, Prospective, Parallel-Group, Randomized Clinical Trial Ann. Thorac. Surg., October 1, 2011; 92(4): 1217 - 1225. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Kanzaki, M. Yamato, J. Yang, H. Sekine, R. Takagi, T. Isaka, T. Okano, and T. Onuki Functional closure of visceral pleural defects by autologous tissue engineered cell sheets Eur J Cardiothorac Surg, October 1, 2008; 34(4): 864 - 869. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Tansley, F. Al-Mulhim, E. Lim, G. Ladas, and P. Goldstraw A prospective, randomized, controlled trial of the effectiveness of BioGlue in treating alveolar air leaks J. Thorac. Cardiovasc. Surg., July 1, 2006; 132(1): 105 - 112. [Abstract] [Full Text] [PDF] |
||||
![]() |
I. Matsumoto, Y. Ohta, M. Oda, Y. Tsunezuka, M. Tamura, K. Kawakami, and G. Watanabe Free Pericardial Fat Pads Can Act as Sealant for Preventing Alveolar Air Leaks Ann. Thorac. Surg., December 1, 2005; 80(6): 2321 - 2324. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Lois and M. Noppen Bronchopleural Fistulas: An Overview of the Problem With Special Focus on Endoscopic Management Chest, December 1, 2005; 128(6): 3955 - 3965. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. S. Allen, D. E. Wood, R. W. Hawkinson, D. H. Harpole, R. J. McKenna, G. L. Walsh, E. Vallieres, D. L. Miller, F. C. Nichols III, W. R. Smythe, et al. Prospective randomized study evaluating a biodegradable polymeric sealant for sealing intraoperative air leaks that occur during pulmonary resection Ann. Thorac. Surg., May 1, 2004; 77(5): 1792 - 1801. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Fabian, J. A. Federico, and R. B. Ponn Fibrin glue in pulmonary resection: a prospective, randomized, blinded study Ann. Thorac. Surg., May 1, 2003; 75(5): 1587 - 1592. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. W. Herget, M. Kassa, U. N. Riede, Y. Lu, L. Brethner, and J. Hasse Experimental use of an albumin-glutaraldehyde tissue adhesive for sealing pulmonary parenchyma and bronchial anastomoses Eur J Cardiothorac Surg, January 1, 2001; 19(1): 4 - 9. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Nomori, H. Horio, and K. Suemasu Mixing collagen with fibrin glue to strengthen the sealing effect for pulmonary air leakage Ann. Thorac. Surg., November 1, 2000; 70(5): 1666 - 1670. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. K. Kjaergard, J. H. Pedersen, M. Krasnik, U. S. Weis-Fogh, H. Fleron, and H. E. Griffin Prevention of Air Leakage by Spraying Vivostat Fibrin Sealant After Lung Resection in Pigs Chest, April 1, 2000; 117(4): 1124 - 1127. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Kinoshita, S. Miyoshi, M. Katoh, T. Yoshimasu, M. Juri, S. Maebeya, and Y. Naito Intrapleural Administration of a Large Amount of Diluted Fibrin Glue for Intractable Pneumothorax Chest, March 1, 2000; 117(3): 790 - 795. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. A. Feito, A. M. Rath, E. Longchampt, and J. Azorin Experimental study on the in vivo behaviour of a new collagen glue in lung surgery Eur J Cardiothorac Surg, January 1, 2000; 17(1): 8 - 13. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Otani, Y. Tabata, and Y. Ikada Sealing effect of rapidly curable gelatin-poly (L-glutamic acid) hydrogel glue on lung air leak Ann. Thorac. Surg., April 1, 1999; 67(4): 922 - 926. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Nomori, H. Horio, S. Morinaga, and K. Suemasu Gelatin-resorcinol-formaldehyde-glutaraldehyde glue for sealing pulmonary air leaks during thoracoscopic operation Ann. Thorac. Surg., January 1, 1999; 67(1): 212 - 216. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Wong and P. Goldstraw Effect of Fibrin Glue in the Reduction of Postthoracotomy Alveolar Air Leak Ann. Thorac. Surg., October 1, 1997; 64(4): 979 - 981. [Abstract] [Full Text] |
||||
![]() |
A. G. Fleisher, K. G. Evans, B. Nelems, and R. J. Finley Effect of routine fibrin glue use on the duration of air leaks after lobectomy Ann. Thorac. Surg., January 1, 1990; 49(1): 133 - 134. [Abstract] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |