ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
George A. Liebler
John A. Burkholder
Thomas D. Maher
Daniel H. Benckart
George J. Magovern, Jr.
Ignacio Y. Christlieb
George J. Magovern, Sr.
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Park, S. B.
Right arrow Articles by Magovern, G. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Park, S. B.
Right arrow Articles by Magovern, G. J., Sr.

Ann Thorac Surg 1986;42:627-631
© 1986 The Society of Thoracic Surgeons


Articles

Mechanical Support of the Failing Heart

Sang B. Park, M.D.*, George A. Liebler, M.D., John A. Burkholder, M.D., Thomas D. Maher, M.D., Daniel H. Benckart, M.D., George J. Magovern, Jr., M.D., Ignacio Y. Christlieb, M.D., Race L. Kao, Ph.D., George J. Magovern, Sr., M.D.

From the Allegheny General Hospital, Pittsburgh, PA

* Address reprint requests to Dr. Park, Department of Surgery, Allegheny General Hospital, 320 E North Ave, Pittsburgh, PA 15212

Mechanical ventricular assist with a centrifugal pump with or without anticoagulation for an extended period has been used in 41 patients with postcardiotomy ventricular failure. Left ventricular, right ventricular, and biventricular assist were required.

The efficacy and safety of mechanical ventricular assist have been documented. Marked improvement in survival has been observed in the more recent part of this series, and is attributed to earlier employment of the assist device, maintenance of better flow rates near physiological levels, and use of biventricular assist to provide effective circulatory support.

Mechanical ventricular assist is easy to use, and the conversion from ordinary cardiopulmonary bypass is also easy. Therefore, mechanical assist provides a very effective means of temporary circulatory assist.




This article has been cited by other articles:


Home page
SEMIN CARDIOTHORAC VASC ANESTHHome page
P. Naughton and C. A. Bashour
Mechanical Support After Cardiac Surgery
Seminars in Cardiothoracic and Vascular Anesthesia, September 1, 2002; 6(3): 237 - 257.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. A. Magovern, M. J. Sussman, A. H. Goldstein, G. W. Szydlowski, E. B. Savage, and S. Westaby
Clinical results with the AB-180 left ventricular assist device
Ann. Thorac. Surg., March 1, 2001; 71(2007): S121 - S124.
[Abstract] [Full Text] [PDF]


Home page
Eur J Cardiothorac SurgHome page
I. Di Bella, F. Pagani, C. Banfi, E. Ardemagni, A. Capo, C. Klersy, and M. Vigano
Results with the Novacor assist system and evaluation of long-term assistance
Eur J Cardiothorac Surg, July 1, 2000; 18(1): 112 - 116.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
D. N. Helman, D. L.S. Morales, N. M. Edwards, D. M. Mancini, J. M. Chen, E. A. Rose, and M. C. Oz
Left ventricular assist device bridge-to-transplant network improves survival after failed cardiotomy
Ann. Thorac. Surg., October 1, 1999; 68(4): 1187 - 1194.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
Yijiang Chen, Bo Liu, and A. Belboul
Cardiopulmonary bypass support for treatment of left ventricular failure following coronary artery bypass grafting: the effects on epicardial microflow and graft flow
Perfusion, September 1, 1996; 11(5): 407 - 414.
[Abstract] [PDF]


Home page
PerfusionHome page
A. El-Banayosy, H. Posival, K. Minami, L. Arusoglu, L. Kizner, T. Breymann, D. Seifert, M. Korner, H. Kortke, O. Fey, et al.
Mechanical circulatory support: lessons from a single centre
Perfusion, March 1, 1996; 11(2): 93 - 102.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
R. Korfer, A. El-Banayosy, H. Posival, K. Minami, M. M. Korner, L. Arusoglu, T. Breymann, L. Kizner, D. Seifert, H. Kortke, et al.
Mechanical circulatory support: The Bad Oeynhausen experience
Ann. Thorac. Surg., February 1, 1995; 59(suppl_1): S56 - S63.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. A. Magovern, A. D. Campellone, and G. J. Magovern
Successful left ventricular assist after a first and second heart operation
Ann. Thorac. Surg., August 1, 1993; 56(2): 379 - 380.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
L. A. R. Golding, R. D. Crouch, R. W. Stewart, R. Novoa, B. W. Lytle, P. M. McCarthy, P. C. Taylor, F. D. Loop, and D. M. Cosgrove III
Postcardiotomy centrifugal mechanical ventricular support
Ann. Thorac. Surg., December 1, 1992; 54(6): 1059 - 1064.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
T. L. Demmy, J. A. Magovern, R. L. Kao, and G. J. Magovern
Resuscitation of injured myocardium with adenosine and biventricular assist
Ann. Thorac. Surg., November 1, 1991; 52(5): 1044 - 1051.
[Abstract] [PDF]


Home page
PerfusionHome page
J. Driessen, G. Fransen, L. Rondelez, E. Schelstraete, and L. Gevaert
Comparison of the standard roller pump and a pulsatile centrifugal pump for extracorporeal circulation during routine coronary artery bypass grafting
Perfusion, October 1, 1991; 6(4): 303 - 311.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
G. P. Noon
Bio-Medicus ventricular assistance
Ann. Thorac. Surg., August 1, 1991; 52(2): 180 - 181.
[PDF]


Home page
J Biomater ApplHome page
S. J. Brister, R. D. Weisel, P. L. Birnbaum, and M. M. Madonik
Ventricular Assistance with a Centrifugal Pump
J Biomater Appl, April 1, 1990; 4(4): 391 - 404.
[PDF]


Home page
Ann. Thorac. Surg.Home page
D. M. Rose, M. Connolly, J. N. Cunningham Jr, and F. C. Spencer
Technique and results with a roller pump left and right heart assist device
Ann. Thorac. Surg., January 1, 1989; 47(1): 124 - 129.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
D. G. Pennington, L. R. McBride, M. T. Swartz, K. R. Kanter, G. C. Kaiser, H. B. Barner, L. W. Miller, K. S. Naunheim, A. C. Fiore, and V. L. Willman
Use of the Pierce-Donachy ventricular assist device in patients with cardiogenic shock after cardiac operations
Ann. Thorac. Surg., January 1, 1989; 47(1): 130 - 135.
[Abstract] [PDF]


Home page
PerfusionHome page
J. A Odell, U. von Oppell, H. Reichenspurner, A. Macdonald, D. Boehm, S. Tate, and B. Reichart
Left heart assist device: a simple method to conserve associated blood loss
Perfusion, July 1, 1988; 3(3): 213 - 217.
[PDF]


Home page
PerfusionHome page
E. B Diethrich, I. Bahadir, G. Mandile, and M. Gordon
A new ventricu lar assist device for acute cardiac failure: report of initial use for biventricular support
Perfusion, October 1, 1987; 2(4): 245 - 261.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1986 by The Society of Thoracic Surgeons.