ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bolooki, H.
Right arrow Articles by Palatianos, G. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bolooki, H.
Right arrow Articles by Palatianos, G. M.

The Annals of Thoracic Surgery, Vol 42, 494-499, Copyright © 1986 by The Society of Thoracic Surgeons


ARTICLES

Comparison of long-term results of Carpentier-Edwards and Hancock bioprosthetic valves

H Bolooki, GA Kaiser, SM Mallon and GM Palatianos

The long-term survival following valve replacement with Carpentier- Edwards or Hancock bioprostheses was compared between the two valve models and between the two groups totaling 407 patients who were discharged after valve replacement beginning in 1974. The two groups of patients were treated in a nonrandomized fashion. The actuarial survival for 299 patients with Carpentier-Edwards valves was 94 +/- 1.5% (+/- standard error) and 93 +/- 1.7% after 5 and 8 years of follow- up, respectively. Comparable figures for 108 patients undergoing valve replacement with Hancock valves were 89 +/- 3.0% and 83 +/- 3.7%, respectively (p = not significant [NS]). The probability of freedom from death and valve removal after 5 and 8 years of follow-up was 91 +/- 1.8% and 79 +/- 4.6%, respectively, with the Carpentier-Edwards valve and 84 +/- 3.5% and 75 +/- 4.3%, respectively, with the Hancock valve (p = NS). An accelerated rate of attrition for both valves was observed in the mitral position. There were no significant differences in actuarial survival between the two valves in the mitral or the aortic position or in the incidence of major valve-related complications.


This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
J. I. Fann, D. C. Miller, KathleenA. Moore, R. S. Mitchell, P. E. Oyer, E. B. Stinson, R. C. Robbins, B. A. Reitz, and N. E. Shumway
Twenty-Year Clinical Experience With Porcine Bioprostheses
Ann. Thorac. Surg., November 1, 1996; 62(5): 1301 - 1311.