The Annals of Thoracic Surgery, Vol 41, 51-53, Copyright © 1986 by The Society of Thoracic Surgeons
JD Cooper, M Perelman, TR Todd, RJ Ginsberg, GA Patterson and FG Pearson
We have used a cautery dissection technique, initially described by
Perelman, to facilitate nonanatomical pulmonary resections in certain
instances in which the anatomical location of the lesion made wedge
excision by standard methods difficult or impossible. With the precision
cautery technique, the raw surface of the lung is left charred and allows
minimum or no air leakage following the procedure. We have found this
method a useful addition to existing techniques for pulmonary resection.
ARTICLES
Precision cautery excision of pulmonary lesions
This article has been cited by other articles:
![]() |
C. Andreetti, F. Venuta, M. Anile, T. De Giacomo, D. Diso, M. Di Stasio, E. A. Rendina, and G. F. Coloni Pleurodesis with an autologous blood patch to prevent persistent air leaks after lobectomy J. Thorac. Cardiovasc. Surg., March 1, 2007; 133(3): 759 - 762. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Shigemura, A. Akashi, T. Nakagiri, M. Ohta, and H. Matsuda A new tissue-sealing technique using the ligasure system for nonanatomical pulmonary resection: preliminary results of sutureless and stapleless thoracoscopic surgery Ann. Thorac. Surg., April 1, 2004; 77(4): 1415 - 1418. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. P. Brega Massone, B. Magnani, B. Conti, C. Lequaglie, and I. Cataldo Cauterization Versus Fibrin Glue for Aerostasis in Precision Resections for Secondary Lung Tumors Ann. Surg. Oncol., May 1, 2003; 10(4): 441 - 446. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. P.C. Yim, E. A. Rendina, S. R. Hazelrigg, L. T. C. Chow, T.-W. Lee, S. Wan, and A. A. Arifi A new technological approach to nonanatomical pulmonary resection: saline enhanced thermal sealing Ann. Thorac. Surg., November 1, 2002; 74(5): 1671 - 1676. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Venuta, E. A. Rendina, T. De Giacomo, I. Flaishman, E. Guarino, A. M. Ciccone, and C. Ricci Technique to reduce air leaks after pulmonary lobectomy Eur. J. Cardiothorac. Surg., April 1, 1999; 13(4): 361 - 364. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. J. Keenan, R. J. Landreneau, S. R. Hazelrigg, and P. F. Ferson VIDEO-ASSISTED THORACIC SURGICAL RESECTION WITH THE NEODYMIUM:YTTRIUM-ALUMINUM-GARNET LASER J. Thorac. Cardiovasc. Surg., August 1, 1995; 110(2): 363 - 367. [Abstract] [Full Text] |
||||