ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Olivier, H. F.
Right arrow Articles by Magovern, G. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Olivier, H. F., Jr
Right arrow Articles by Magovern, G. J.

The Annals of Thoracic Surgery, Vol 38, 586-591, Copyright © 1984 by The Society of Thoracic Surgeons


ARTICLES

Use of the BioMedicus centrifugal pump in traumatic tears of the thoracic aorta

HF Olivier Jr, TD Maher, GA Liebler, SB Park, JA Burkholder and GJ Magovern

Traumatic blunt thoracic aortic injury is a clinical entity of increasing incidence. After the diagnosis of traumatic tear of the aorta is made, there is some controversy over whether the aorta should be repaired using cardiopulmonary bypass, a heparinized shunt, or cross- clamping and graft interposition without a shunt or bypass. At Allegheny General Hospital, 19 patients were treated for traumatic tears of the thoracic aorta between July 1, 1977, and June 30, 1983. They can be divided into two groups: Group 1 (July 1, 1977, through October 31, 1981), in which no shunt or bypass or only a heparinized shunt was used, and Group 2 (November 1, 1981, through June 30, 1983), in which left atrium-femoral artery bypass was performed using a BioMedicus heparinless pump and tubing. Among the 10 patients in Group 1, 4 died and 2 had paraplegia postoperatively. Among the 9 patients in Group 2, 1 died and none experienced paraplegia following operation. We believe that the BioMedicus centrifugal pump is a simple, safe means of perfusing the lower body, kidneys, and spinal column without necessitating heparinization in a patient with multiple injuries or the placement of a cumbersome heparinized shunt. Because of the simplicity and the reliability demonstrated, this pump should be considered for use in all patients with traumatic tears of the thoracic aorta.


This article has been cited by other articles:


Home page
SEMIN CARDIOTHORAC VASC ANESTHHome page
E. A. Hessel
Bypass Techniques for Descending Thoracic Aortic Surgery
Seminars in Cardiothoracic and Vascular Anesthesia, November 1, 2001; 5(4): 293 - 320.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
A. T. Gurbuz, D. S. Weiman, and J. W. Pate
Traumatic injury to the thoracic aorta
Ann. Thorac. Surg., September 1, 1999; 68(3): 1116 - 1117.
[Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
H. J. Safi, A. Winnerkvist, C. C. Miller III, D. C. Iliopoulos, M. J. Reardon, R. Espada, and J. C. Baldwin
Effect of extended cross-clamp time during thoracoabdominal aortic aneurysm repair
Ann. Thorac. Surg., October 1, 1998; 66(4): 1204 - 1208.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. S. Gammie, A. S. Shah, B. G. Hattler, R. L. Kormos, A. B. Peitzman, B. P. Griffith, and S. M. Pham
Traumatic aortic rupture: diagnosis and management
Ann. Thorac. Surg., October 1, 1998; 66(4): 1295 - 1300.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
C. Yamashita, M. Okada, T. Yoshimura, T. Azami, K. Nakagiri, H. Wakiyama, and K. Ataka
Impact of Retrograde Cerebral Perfusion With Posterolateral Thoracotomy on Distal Arch Aneurysm Repair
Ann. Thorac. Surg., April 1, 1998; 65(4): 955 - 960.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
A. C. Nicolosi, G. H. Almassi, M. Bousamra II, G. B. Haasler, and G. N. Olinger
Mortality and Neurologic Morbidity After Repair of Traumatic Aortic Disruption
Ann. Thorac. Surg., March 1, 1996; 61(3): 875 - 878.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
D. K. Kaplan, N. Atsumi, M. N. D'Ambra, and G. J. Vlahakes
Distal Circulatory Support for Thoracic Aortic Operations: Effects on Intracranial Pressure
Ann. Thorac. Surg., February 1, 1995; 59(2): 448 - 452.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
M. C. Mauney, L. H. Blackbourne, S. E. Langenburg, S. A. Buchanan, I. L. Kron, and C. G. Tribble
Prevention of Spinal Cord Injury After Repair of the Thoracic or Thoracoabdominal Aorta
Ann. Thorac. Surg., January 1, 1995; 59(1): 245 - 252.
[Abstract] [Full Text]


Home page
VASC ENDOVASCULAR SURGHome page
Gang Liu, S. Fukunaga, T. Sueda, and Y. Matsuura
Efficiency of a Centrifugal Pump for Distal Circulatory Support During Cross-clamping of the Descending Thoracic Aorta
Vascular and Endovascular Surgery, April 1, 1994; 28(3): 167 - 176.
[Abstract] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
H. G. Borst, M. Jurmann, B. Buhner, and J. Laas
Risk of replacement of descending aorta with a standardized left heart bypass technique
J. Thorac. Cardiovasc. Surg., January 1, 1994; 107(1): 126 - 133.
[Abstract] [Full Text]


Home page
VASC ENDOVASCULAR SURGHome page
M. Shimada, K. Okadome, K. Komori, H. Takeuchi, and K. Sugimachi
A New Application of Centrifugal Pump to Axilloiliac Temporary Bypass During Surgery of Thoracic Aortic Aneurysm--A Case Report
Vascular and Endovascular Surgery, March 1, 1993; 27(2): 140 - 146.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1984 by The Society of Thoracic Surgeons.