Ann Thorac Surg 1984;37:167-168
© 1984 The Society of Thoracic Surgeons
From the Division of Cardiovascular and Thoracic Surgery, University of Cincinnati Medical Center, and the Department of Cardiac Surgery, Christ Hospital, Cincinnati, OH
Accepted for publication March 24, 1983.
* Address reprint requests to Dr. Flege, Department of Cardiac Surgery, The Christ Hospital, Cincinnati, OH 45219
We used pulmonary arterial balloon counterpulsation to treat successfully a patient with severe right ventricular failure following mitral valve replacement. The balloon was placed through a vascular graft sutured as a diverticulum to the main pulmonary artery.
This article has been cited by other articles:
![]() |
G. V. Letsou, K. L. Franco, W. Detmer, S. Condos, S. Wolvek, G. J. Walker Smith, and J. C. Baldwin Pulmonary artery balloon counterpulsation: Safe after peripheral placement Ann. Thorac. Surg., March 1, 1993; 55(3): 741 - 746. [Abstract] [PDF] |
||||
![]() |
H. Raffa, Mohamed Taher Kayali, and Abdool Aniff Sorefan Successful treatment of acute postperfusion right ventricular failure by atrial septal defect creation Perfusion, October 1, 1991; 6(4): 275 - 278. [Abstract] [PDF] |
||||
![]() |
P. D. Skillington, G. S. Couper, P. S. Peigh, D. Fitzgerald, and L. H. Cohn Pulmonary artery balloon counterpulsation for intraoperative right ventricular failure Ann. Thorac. Surg., April 1, 1991; 51(4): 658 - 660. [Abstract] [PDF] |
||||
![]() |
L. Weinhaus, C. Canter, M. Noetzel, W. McAlister, and T. L. Spray Extracorporeal membrane oxygenation for circulatory support after repair of congenital heart defects Ann. Thorac. Surg., August 1, 1989; 48(2): 206 - 212. [Abstract] [PDF] |
||||
![]() |
J. M. Caralps, J. M. Padro, M. L. Camara, A. Aris, and O. Bonnin Creation of an Atrial Septal Defect for Acute Postperfusion Right Ventricular Failure Ann. Thorac. Surg., April 1, 1987; 43(4): 435 - 436. [Abstract] [PDF] |
||||
![]() |
P. A. Spence, C. M. Peniston, N. Mihic, A. K. Jabr, and T. A. Salerno A Rational Approach to the Selection of an Assist Device for the Failing Right Ventricle Ann. Thorac. Surg., June 1, 1986; 41(6): 606 - 608. [Abstract] [PDF] |
||||
![]() |
P. N. Symbas, P. P. McKeown, A. H. Santora, and S. E. Vlasis Pulmonary Artery Balloon Counterpulsation for Treatment of Intraoperative Right Ventricular Failure Ann. Thorac. Surg., May 1, 1985; 39(5): 437 - 440. [Abstract] [PDF] |
||||
![]() |
P. A. Spence, R. D. Weisel, J. Easdown, A. K. Jabr, V. Yap, and T. A. Salerno The Hemodynamic Effects and Mechanism of Action of Pulmonary Artery Balloon Counterpulsation in the Treatment of Right Ventricular Failure during Left Heart Bypass Ann. Thorac. Surg., April 1, 1985; 39(4): 329 - 335. [Abstract] [PDF] |
||||
![]() |
M. Opravil, A. J. Gorman, T. C. Krejcie, L. L. Michaelis, and J. M. Moran Pulmonary Artery Balloon Counterpulsation for Right Ventricular Failure: I. Experimental Results Ann. Thorac. Surg., September 1, 1984; 38(3): 242 - 253. [Abstract] [PDF] |
||||
![]() |
J. M. Moran, M. Opravil, A. J. Gorman, H. Rastegar, S. N. Meyers, and L. L. Michaelis Pulmonary Artery Balloon Counterpulsation for Right Ventricular Failure: II. Clinical Experience Ann. Thorac. Surg., September 1, 1984; 38(3): 254 - 259. [Abstract] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |