ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Boers, M.
Right arrow Articles by Wildevuur, C. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Boers, M.
Right arrow Articles by Wildevuur, C. R.

The Annals of Thoracic Surgery, Vol 35, 455-462, Copyright © 1983 by The Society of Thoracic Surgeons


ARTICLES

Two membrane oxygenators and a bubbler: a clinical comparison

M Boers, JJ van den Dungen, GF Karliczek, U Brenken, JN van der Heide and CR Wildevuur

We compared the hemocompatibility of the Polystan bubble oxygenator and the Travenol TMO and SciMed spiral-coil membrane oxygenators in 43 patients undergoing aortic valve replacement. In a subgroup of 27 patients, we collected hematological data and correlated platelet behavior with hemostasis. We found no differences in blood loss or blood (product) requirements among the groups. Platelet and erythrocyte damage was less in the membrane oxygenator groups than in the bubble oxygenator group. Differences in adenosine diphosphate-induced platelet aggregation were equivalent. Drops in this function concurred with intensified cardiotomy suction and administration of protamine. Leukocytosis after bypass was most marked in the SciMed group. Duration of bypass correlated with blood loss and blood requirements in the operating theater. Platelet counts shortly after bypass correlated negatively with duration of bypass and blood loss in the intensive care unit. Platelet function correlated with none of the factors just mentioned. We conclude that platelets and erythrocytes are preserved better by the membrane oxygenator than by the bubbler. The TMO system causes more erythrocyte damage than the SciMed oxygenator, probably due to TMO's dual-pump system. Clinical evidence for these improvements was not found, and this will be possible only when the other factors responsible for blood damage can be controlled.


This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
A. Weerasinghe and K. M. Taylor
The platelet in cardiopulmonary bypass
Ann. Thorac. Surg., December 1, 1998; 66(6): 2145 - 2152.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
R. G. H. Speekenbrink, A. B. A. Vonk, C. R. H. Wildevuur, and L. Eijsman
Hemostatic Efficacy of Dipyridamole, Tranexamic Acid, and Aprotinin in Coronary Bypass Grafting
Ann. Thorac. Surg., February 1, 1995; 59(2): 438 - 442.
[Abstract] [Full Text]


Home page
PerfusionHome page
K. Rais-Bahrami, G. Mikesell, W. Seale, O. Rivera, J. Hearty, and B. Short
In vitro evaluation of the Mera Silox-S 0.5 and 0.8 m2 silicone hollow-fibre membrane oxygenator for use in neonatal ECMO
Perfusion, October 1, 1992; 7(4): 315 - 320.
[Abstract] [PDF]


Home page
VASC ENDOVASCULAR SURGHome page
A. Belboul, N. A. Khaja, P. Bergman, D. Roberts, and G. William-Olsson
Postoperative Morbidity Following Red Cell Deformability Changes During Cardiopulmonary Bypass Using Bubble and Membrane Oxygenators
Vascular and Endovascular Surgery, July 1, 1989; 23(4): 258 - 264.
[Abstract] [PDF]


Home page
PerfusionHome page
D.T. Pearson and B. McArdle
Haemocompatibility of membrane and bubble oxygenators
Perfusion, January 1, 1989; 4(1): 9 - 24.
[Abstract] [PDF]


Home page
PerfusionHome page
B. J Zadeh, R. Holazo, C. Conlon, W D. Lazenby, O W. Isom, and K. H Krieger
A clinical evaluation of three modern blood oxygenators
Perfusion, October 1, 1987; 2(4): 263 - 270.
[Abstract] [PDF]


Home page
PerfusionHome page
D. T Pearson, M. P Holden, S. J Poslad, A. Murray, and P. S Waterhouse
A clinical evaluation of the performance characteristics of one membrane and five bubble oxygenators: gas transfer and gaseous microemboli production
Perfusion, January 1, 1986; 1(1): 15 - 27.
[Abstract] [PDF]


Home page
PerfusionHome page
D. T Pearson, B. McArdle, S. J Poslad, and A. Murray
A clinical evaluation of the performance characteristics of one membrane and five bubble oxygenators: haemocompatibility studies
Perfusion, January 1, 1986; 1(2): 81 - 98.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1983 by The Society of Thoracic Surgeons.