ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Levi Watkins, Jr.
Vincent L. Gott
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Watkins, L.
Right arrow Articles by Gott, V. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Watkins, L., Jr.
Right arrow Articles by Gott, V. L.

Ann Thorac Surg 1982;34:515-520
© 1982 The Society of Thoracic Surgeons


Articles

Implantation of the Automatic Defibrillator: The Subxiphoid Approach

Levi Watkins, Jr., M.D.*, M. Mirowski, M.D., Morton M. Mower, M.D., Philip R. Reid, M.D., Paul Freund, P.A., Andra Thomas, R.N., Myron L. Weisfeldt, M.D., Vincent L. Gott, M.D.

Departments of Surgery and Medicine, The Johns Hopkins Medical Institutions, Baltimore, and the Department of Medicine, Sinai Hospital of Baltimore, Baltimore, MD.

Accepted for publication October 10, 1981.

* Address reprint requests to Dr. Watkins, Department of Surgery, The Johns Hopkins Medical Institutions, Baltimore, MD 21205.

The automatic implantable defibrillator is an electronic device capable of diagnosing and correcting malignant venticular arrhythmias. While major thoracic surgery was required in the original 24 implants, a new technique for implanting the device has been developed. The first subxiphoid implantations have been accomplished with the defibrillatory function successfully tested intraoperatively. The advantages and indications of the subxiphoid technique are reviewed.




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
J. S. Lawton, K. A. Ellenbogen, M. A. Wood, B. S. Stambler, J. A. Spratt, A. S. Wechsler, and R. J. Damiano Jr
Clinical experience with nonthoracotomy cardioverter defibrillators
Ann. Thorac. Surg., May 1, 1995; 59(5): 1092 - 1099.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
A. Markewitz, H. Kaulbach, S. Mattke, U. Dorwarth, C. Weinhold, E. Hoffmann, G. Steinbeck, and B. Reichart
One-incision approach for insertion of implantable cardioverter defibrillators
Ann. Thorac. Surg., December 1, 1994; 58(6): 1609 - 1613.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. J. Mack, T. E. Acuff, and W. H. Ryan
Implantable cardioverter defibrillator: The role of thoracoscopy
Ann. Thorac. Surg., September 1, 1993; 56(3): 739 - 740.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
R. J. Damiano, A. H. Foster, K. A. Ellenbogen, M. A. Wood, B. S. Stambler, W. J. Welch, and A. S. Wechsler
Implantation of cardioverter defibrillators in the post-sternotomy patient
Ann. Thorac. Surg., June 1, 1992; 53(6): 978 - 983.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
S. Curiale, L. E. Rosenfeld, and J. A. Elefteriades
Cosmetic approach for placement of the automatic implantable cardioverter-defibrillator in young women
Ann. Thorac. Surg., December 1, 1991; 52(6): 1340 - 1341.
[Abstract] [PDF]


Home page
Arch SurgHome page
A. D. Slater, I. Singer, C. Stavens, M. J. Springer, and L. A. Gray Jr
Lateral Thoracotomy for the Automatic Implantable Defibrillator
Arch Surg, June 1, 1991; 126(6): 778 - 781.
[Abstract] [PDF]


Home page
Arch SurgHome page
B. M. Blakeman, D. Wilber, and R. Pifarre
Median Sternotomy for Implantable Cardioverter/Defibrillator
Arch Surg, September 1, 1989; 124(9): 1065 - 1066.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
G. M. Lawrie, R. R. Kaushik, and A. Pacifico
Right mini-thoracotomy: An adjunct to left subcostal automatic implantable cardioverter defibrillator implantation
Ann. Thorac. Surg., May 1, 1989; 47(5): 780 - 781.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
R. J. Thurer, R. M. Luceri, and H. Bolooki
Automatic Implantable Cardioverter-Defibrillator: Techniques of Implantation and Results
Ann. Thorac. Surg., August 1, 1986; 42(2): 143 - 147.
[Abstract] [PDF]


Home page
ANN INTERN MEDHome page
M. MIROWSKI, P. R. REID, R. A. WINKLE, M. M. MOWER, L. WATKINS Jr., E. B. STINSON, L. S. C. GRIFFITH, C. H. KALLMAN, and M. L. WEISFELDT
Mortality in Patients with Implanted Automatic Defibrillators
Ann Intern Med, May 1, 1983; 98(5_Part_1): 585 - 588.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1982 by The Society of Thoracic Surgeons.