ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Alberto J. Larrieu
Peter Allen
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Larrieu, A. J.
Right arrow Articles by Allen, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Larrieu, A. J.
Right arrow Articles by Allen, P.

Ann Thorac Surg 1982;34:192-195
© 1982 The Society of Thoracic Surgeons


Articles

Strut Fracture and Disc Embolization of a Björk-Shiley Mitral Valve Prosthesis: Localization of Embolized Disc by Computerized Axial Tomography

Alberto J. Larrieu, M.D.*, Eduardo Puglia, M.D., Peter Allen, M.D.

From the University of British Columbia, Department of Surgery, Division of Cardiothoracic Surgery, Vancouver, BC, Canada

Accepted for publication August 20, 1981.

* Address reprint requests to Dr. Larrieu, Northern Medical Building, 1335 W Tabor Rd, Suite 307, Philadelphia, PA 19141

The case of a patient who survived strut fracture and embolization of a Björk-Shiley mitral prosthetic disc is presented. Prompt surgical treatment was directly responsible for survival. In addition, computerized axial tomography of the abdomen aided in localizing and retrieving the embolized disc, which was lodged at the origin of the superior mesenteric artery. A review of similar case reports from the literature supports our conclusions that the development of acute heart failure and absent or muffled prosthetic heart sounds in a patient with a Björk-Shiley prosthetic heart valve inserted prior to 1978 should raise the possibility of valve dysfunction and lead to early reoperation.




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
P. N. Hendel
Bjork-Shiley strut fracture and disc escape: Literature review and a method of disc retrieval
Ann. Thorac. Surg., March 1, 1989; 47(3): 436 - 440.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
P. K. Davis, J. L. Myers, J. L. Pennock, and B. L. Thiele
Strut Fracture and Disc Embolization in Bjork-Shiley Mitral Valve Prostheses: Diagnosis and Management
Ann. Thorac. Surg., July 1, 1985; 40(1): 65 - 68.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. A. Odell, J. Durandt, D. M. Shama, and S. Vythilingum
Spontaneous Embolization of a St. Jude Prosthetic Mitral Valve Leaflet
Ann. Thorac. Surg., June 1, 1985; 39(6): 569 - 572.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1982 by The Society of Thoracic Surgeons.