ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Van Trigt, P.
Right arrow Articles by Wechsler, A. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Van Trigt, P.
Right arrow Articles by Wechsler, A. S.

The Annals of Thoracic Surgery, Vol 33, 585-592, Copyright © 1982 by The Society of Thoracic Surgeons


ARTICLES

The effect of PEEP on left ventricular diastolic dimensions and systolic performance following myocardial revascularization

P Van Trigt, TL Spray, MK Pasque, RB Peyton, GL Pellom, CM Christian, L Fagraeus and AS Wechsler

To quantitate the alterations in left ventricular (LV) dimensions and performance at successive levels of positive end-expiratory pressure (PEEP), 16 patients undergoing coronary artery bypass grafting (CABG) underwent instrumentation with ultrasonic dimension transducers to measure the minor-axis diameter of the left ventricle. Matched micromanometers were placed to measure intracavitary LV pressure and intrathoracic pressure. LV pressure and dimension data were recorded and computer analyzed during continuous positive-pressure ventilation at 0, 5, 10, and 15 cm H2O of PEEP 4 to 8 hours postoperatively. Preload was determined by the end-diastolic minor-axis diameter, cardiac output was measured by thermodilution, and indices of LV contractility assessed included the maximal velocity of minor-axis shortening and the slope of the end-systolic pressure-diameter relationship. PEEP produced a progressive increase in intrathoracic pressure associated with a fall in cardiac output; this was associated with a decrease in LV end-diastolic diameter and no significant change in the maximal velocity of minor-axis shortening or the slope of the end-systolic pressure-diameter relationship. Our results indicate that PEEP of 10 cm H2O or greater will produce a significant fall in cardiac output in patients following CABG, due to a decrease in preload rather than impaired LV contractility.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
K. Bendjelid, P. M. Suter, and J. A. Romand
The respiratory change in preejection period: a new method to predict fluid responsiveness
J Appl Physiol, January 1, 2004; 96(1): 337 - 342.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1982 by The Society of Thoracic Surgeons.