To quantitate the alterations in left ventricular (LV) dimensions and performance at successive levels of positive end-expiratory pressure (PEEP), 16 patients undergoing coronary artery bypass grafting (CABG) underwent instrumentation with ultrasonic dimension transducers to measure the minor-axis diameter of the left ventricle. Matched micromanometers were placed to measure intracavitary LV pressure and intrathoracic pressure. LV pressure and dimension data were recorded and computer analyzed during continuous positive-pressure ventilation at 0, 5, 10, and 15 cm H2O of PEEP 4 to 8 hours postoperatively. Preload was determined by the end-diastolic minor-axis diameter, cardiac output was measured by thermodilution, and indices of LV contractility assessed included the maximal velocity of minor-axis shortening and the slope of the end-systolic pressure-diameter relationship.
PEEP produced a progressive increase in intrathoracic pressure associated with a fall in cardiac output; this was associated with a decrease in LV end-diastolic diameter and no significant change in the maximal velocity of minor-axis shortening or the slope of the end-systolic pressure-diameter relationship. Our results indicate that PEEP of 10 cm H2O or greater will produce a significant fall in cardiac output in patients following CABG, due to a decrease in preload rather than impaired LV contractility.
This article has been cited by other articles:
![]() |
K. Bendjelid, P. M. Suter, and J. A. Romand The respiratory change in preejection period: a new method to predict fluid responsiveness J Appl Physiol, January 1, 2004; 96(1): 337 - 342. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. E. Lores, B. A. Keagy, T. Vassiliades, G. W. Henry, C. L. Lucas, and B. R. Wilcox Cardiovascular Effects of Positive End-Expiratory Pressure (PEEP) after Pneumonectomy in Dogs Ann. Thorac. Surg., November 1, 1985; 40(5): 464 - 468. [Abstract] [PDF] |
||||
![]() |
P. Van Trigt, T. L. Spray, M. K. Pasque, R. B. Peyton, G. L. Pellom, C. M. Christian, L. Fagraeus, and A. S. Wechsler The Influence of Time on the Response to Dopamine after Coronary Artery Bypass Grafting: Assessment of Left Ventricular Performance and Contractility Using Pressure/Dimension Analyses Ann. Thorac. Surg., January 1, 1983; 35(1): 3 - 13. [Abstract] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |