ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Stewart, S.
Right arrow Articles by DeWeese, J. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Stewart, S.
Right arrow Articles by DeWeese, J. A.

The Annals of Thoracic Surgery, Vol 31, 259-265, Copyright © 1981 by The Society of Thoracic Surgeons


ARTICLES

False aneurysm and pseudo-false aneurysm of the left ventricle: etiology, pathology, diagnosis, and operative management

S Stewart, R Huddle, I Stuard, BF Schreiner and JA DeWeese

Four patients are presented in whom either a false aneurysm or a "pseudo-false" aneurysm of the left ventricle developed following a myocardial infarction. False aneurysms of the left ventricle are unusual and are distinctly different from the more common true aneurysms. A false aneurysm is the result of a contained hematoma dissecting, into a transmural infarct. It communicates with the left ventricle through a small orifice. Previous descriptions of false aneurysms have stressed that their wall consists of pericardium and mural thrombus and lack identifiable epicardial or myocardial elements. Two pseudo-false aneurysms are described. They communicated with the left ventricle through a small orifice but their wall contained myocardial tissue. False aneurysms have a tendency to rupture and therefore their presence alone is an indication for operation. One of the pseudo-false aneurysms discussed ruptured into the right ventricle. The operation for false aneurysm may be simpler than that for true aneurysm since it might be possible to close the small communication into the left ventricle without resecting the entire aneurysm wall.


This article has been cited by other articles:


Home page
Eur. J. Cardiothorac. Surg.Home page
P. Ortu, C. A. Mestres, J. M. Miro, and J. L. Pomar
Staphylococcal postoperative subannular left ventricular false aneurysm
Eur. J. Cardiothorac. Surg., February 1, 2003; 23(2): 244 - 245.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
T. TREASURE
False aneurysm of the left ventricle
Heart, July 1, 1998; 80(1): 7 - 8.
[Full Text]


Home page
Ann. Thorac. Surg.Home page
A. K. Das, G. M. Wilson, and A. P. Furnary
Coincidence of True and False Left Ventricular Aneurysm
Ann. Thorac. Surg., September 1, 1997; 64(3): 831 - 834.
[Abstract] [Full Text]


Home page
ANGIOLOGYHome page
R. Martin, T. Tegtmeier, A. S. Smith, A. Ognibene, and A. Ognibene
Left Ventricular Pseudoaneurysm Presenting Twenty-eight Months After Myocardial Infarction: A Case Report
Angiology, February 1, 1997; 48(2): 177 - 181.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1981 by The Society of Thoracic Surgeons.