ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Trumbull, H. R.
Right arrow Articles by Nicoloff, D. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Trumbull, H. R.
Right arrow Articles by Nicoloff, D. M.

The Annals of Thoracic Surgery, Vol 30, 52-57, Copyright © 1980 by The Society of Thoracic Surgeons


ARTICLES

A comparison of the effects of membrane and bubble oxygenators on platelet counts and platelet size in elective cardiac operations

HR Trumbull, J Howe, K Mottl and DM Nicoloff

To compare the effects of membrane and bubble oxygenators on platelet counts and the size of circulating platelets, serial hematocrits, platelet counts, and platelet sizing were measured in 23 patients undergoing elective cardiac operations. In 10 patients a bubble oxygenator was used and in 13, a SciMed membrane oxygenator. The two groups were statistically similar with respect to age, weight, time on bypass, and mean blood flow rates during bypass. It was found that platelet counts, when corrected for hemodilution, did not fall from control levels during or up to 24 hours after cardiopulmonary bypass in either group. In both groups, the relative number of platelets per gram of hemoglobin increased slightly during and after bypass, and this increase was significant in the bubble oxygenator group. The average size of circulating platelets increased only in the bubble oxygenator group, and then only in the one-day postoperative sample. These findings suggest that the membrane oxygenator offers no advantage with respect to preservation of platelets during cardiopulmonary bypass lasting up to 2 to 3 hours.


This article has been cited by other articles:


Home page
PerfusionHome page
J. A. Hyde, J. A Chinn, and T. R Graham
Platelets and cardiopulmonary bypass
Perfusion, December 1, 1998; 13(6): 389 - 407.
[PDF]


Home page
PerfusionHome page
D.T. Pearson and B. McArdle
Haemocompatibility of membrane and bubble oxygenators
Perfusion, January 1, 1989; 4(1): 9 - 24.
[Abstract] [PDF]


Home page
PerfusionHome page
D. T Pearson, B. McArdle, S. J Poslad, and A. Murray
A clinical evaluation of the performance characteristics of one membrane and five bubble oxygenators: haemocompatibility studies
Perfusion, January 1, 1986; 1(2): 81 - 98.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1980 by The Society of Thoracic Surgeons.