Ann Thorac Surg 1980;29:522-528
© 1980 The Society of Thoracic Surgeons
Divisions of Cardiovascular Surgery and Intensive Care, the Hospital for Sick Children, Toronto, Ont, Canada
Accepted for publication December 6, 1979.
* Address reprint requests to Dr. Williams, Division of Cardiovascular Surgery, The Hospital for Sick Children, 555 University Ave, Toronto, Ont, Canada
From June, 1977, to December, 1978, 14 children had intraaortic balloon support after open-heart operation. There were 6 long-term survivors. Four of 5 children more than 10 years old and 2 of 5 children between 5 and 10 years old survived. All 4 children less than 5 years old died. In the youngest group, it was difficult to use the balloon successfully because of their very low cardiac output coming off bypass and their greater aortic elasticity. The smallest sizes of balloon available were found to be too long, extending well below the diaphragm in younger patients. In 7 out of 10 patients 5 years old or more, augmentation was obtained.
This article has been cited by other articles:
![]() |
G. Brancaccio, A. Amodeo, Z. Ricci, S. Morelli, M. G. Gagliardi, R. Iacobelli, G. Michielon, S. Picardo, F. Parisi, G. Pongiglione, et al. Mechanical Assist Device as a Bridge to Heart Transplantation in Children Less Than 10 Kilograms Ann. Thorac. Surg., July 1, 2010; 90(1): 58 - 62. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. K. Gandhi, C. B. Huddleston, D. T. Balzer, D. J. Epstein, T. A. Boschert, and C. E. Canter Biventricular Assist Devices as a Bridge to Heart Transplantation in Small Children Circulation, September 30, 2008; 118(14_suppl_1): S89 - S93. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Paul Collison and K. Singh Dagar The role of the Intra-aortic balloon pump in supporting children with acute cardiac failure Postgrad. Med. J., May 1, 2007; 83(979): 308 - 311. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. S. Sharma, S. A. Webber, V. O. Morell, S. K. Gandhi, P. D. Wearden, J. R. Buchanan, and R. L. Kormos Ventricular assist device support in children and adolescents as a bridge to heart transplantation. Ann. Thorac. Surg., September 1, 2006; 82(3): 926 - 932. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Kalavrouziotis, A. Karunaratne, S. Raja, G. Ciotti, M. Purohit, A. F. Corno, and M. Pozzi Intra-aortic balloon pumping in children undergoing cardiac surgery: An update of the Liverpool experience J. Thorac. Cardiovasc. Surg., June 1, 2006; 131(6): 1382 - 1389. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. A. Pinkney, L. L. Minich, L. Y. Tani, G. B. Di Russo, L. G. Veasy, E. C. McGough, and J. A. Hawkins Current results with intraaortic balloon pumping in infants and children Ann. Thorac. Surg., March 1, 2002; 73(3): 887 - 891. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Y. Schure, P. C. Laussen, and F. X. McGowan JR Mechanical Cardiopulmonary Support of Infants and Children With Congenital Heart Disease Seminars in Cardiothoracic and Vascular Anesthesia, March 1, 2001; 5(1): 46 - 54. [Abstract] [PDF] |
||||
![]() |
L. L. Minich, L. Y. Tani, G. M. Pantalos, B. L. Bolland, B. K. Knorr, and J. A. Hawkins Neonatal piglet model of intraaortic balloon pumping: Improved efficacy using echocardiographic timing Ann. Thorac. Surg., November 1, 1998; 66(5): 1527 - 1532. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. L. Walters III, M. Hakimi, M. D. Rice, J. M. Lyons, G. C. Whittlesey, and M. D. Klein Pediatric cardiac surgical ECMO: Multivariate analysis of risk factors for hospital death Ann. Thorac. Surg., August 1, 1995; 60(2): 329 - 337. [Abstract] [PDF] |
||||
![]() |
D. G. Pennington and M. T. Swartz Circulatory support in infants and children Ann. Thorac. Surg., January 1, 1993; 55(1): 233 - 237. [Abstract] [PDF] |
||||
![]() |
S. Ziomek, J. E. Harrell Jr, J. W. Fasules, S. C. Faulkner, C. W. Chipman, M. Moss, E. Frazier, and S. H. Van Devanter Extracorporeal membrane oxygenation for cardiac failure after congenital heart operation Ann. Thorac. Surg., November 1, 1992; 54(5): 861 - 868. [Abstract] [PDF] |
||||
![]() |
W. McGeehin, F. Sheikh, J. S. Donahoo, M. J. Lechman, and H. MacVaugh III Transthoracic Intraaortic Balloon Pump Support: Experience in 39 Patients Ann. Thorac. Surg., July 1, 1987; 44(1): 26 - 30. [Abstract] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |