ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Stoney, W. S.
Right arrow Articles by Thomas, C. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Stoney, W. S.
Right arrow Articles by Thomas, C. S., Jr

The Annals of Thoracic Surgery, Vol 29, 336-340, Copyright © 1980 by The Society of Thoracic Surgeons


ARTICLES

Air embolism and other accidents using pump oxygenators

WS Stoney, WC Alford Jr, GR Burrus, DM Glassford Jr and CS Thomas Jr

A surgery of 349 cardiac surgeons showed that during a six-year period, a pump oxygenator accident serious enough to cause patient injury or death occurred one per 1,000 procedures. A total of 264 deaths occurred as a direct results of an accident. Air embolism and disseminated intravascular coagulation were the two most common problems. Low-level alarm systems were reported to be used by 42% of the respondents and activated clotting times were used by 63%. Rigorous use of alarm systems and heparin monitoring could reduce the incidence of pump- related accidents.


This article has been cited by other articles:


Home page
PerfusionHome page
S. Svenmarker and M. Appelblad
Reporting of perfusion-related incidents: pitfalls and limitations
Perfusion, September 1, 2005; 20(5): 243 - 248.
[PDF]


Home page
PerfusionHome page
D. A Palanzo
Perfusion safety: defining the problem
Perfusion, July 1, 2005; 20(4): 195 - 203.
[Abstract] [PDF]


Home page
PerfusionHome page
J W Mulholland
The Great Britain and Ireland perspective: current perfusion safety issues, preparing for the future
Perfusion, July 1, 2005; 20(4): 217 - 225.
[Abstract] [PDF]


Home page
PerfusionHome page
M. Kurusz and B. D Butler
Bubbles and bypass: an update
Perfusion, January 1, 2004; 19(1_suppl): S49 - S55.
[Abstract] [PDF]


Home page
PerfusionHome page
R. Ginther Jr, R. Fillingham, B. Searles, and E. Darling
Departmental use of perfusion crisis management drills: 2002 survey results
Perfusion, September 1, 2003; 18(5): 299 - 302.
[Abstract] [PDF]


Home page
PerfusionHome page
A. R. Fisher, M. Baker, M. Buffin, P. Campbell, S. Hansbro, S. Kennington, A. Lilley, and M. Whitehorne
Normal and abnormal trans-oxygenator pressure gradients during cardiopulmonary bypass
Perfusion, January 1, 2003; 18(1): 25 - 30.
[Abstract] [PDF]


Home page
PerfusionHome page
R C Groom, R J Forest, J E Cormack, K S Niimi, and J Morton
Parallel replacement of the oxygenator that is not transferring oxygen: the PRONTO procedure
Perfusion, December 1, 2002; 17(6): 447 - 450.
[Abstract] [PDF]


Home page
PerfusionHome page
M Hargrove, B C Ramish, A O'Donnell, and T Aherne
Electrical failure during cardiopulmonary bypass: an evaluation of incidence, causes, management and guidelines for preventative measures
Perfusion, September 1, 2002; 17(5): 369 - 372.
[Abstract] [PDF]


Home page
PerfusionHome page
A. H Stammers and B. L Mejak
An update on perfusion safety: does the type of perfusion practice affect the rate of incidents related to cardiopulmonary bypass?
Perfusion, May 1, 2001; 16(3): 189 - 198.
[Abstract] [PDF]


Home page
PerfusionHome page
B. L Mejak, A. Stammers, E. Rauch, S. Vang, and T. Viessman
A retrospective study on perfusion incidents and safety devices
Perfusion, January 1, 2000; 15(1): 51 - 61.
[Abstract] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
S. Svenmarker, S. Haggmark, E. Jansson, R. Lindholm, M. Appelblad, and T. Aberg
Quality assurance in clinical perfusion
Eur. J. Cardiothorac. Surg., October 1, 1999; 14(4): 409 - 414.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
A R Fisher
The incidence and cause of emergency oxygenator changeovers
Perfusion, May 1, 1999; 14(3): 207 - 212.
[Abstract] [PDF]


Home page
PediatricsHome page
D. Waisman, A. Shupak, G. Weisz, and Y. Melamed
Hyperbaric Oxygen Therapy in the Pediatric Patient: The Experience of the Israel Naval Medical Institute
Pediatrics, November 1, 1998; 102(5): 53e - 53.
[Abstract] [Full Text]


Home page
PerfusionHome page
X. M Mueller, H. T Tevaearai, K. van Ness, J. Horisberger, M. Augstburger, M. Burki, and L. K von Segesser
Air trapping ability of the Spiral GoldTM membrane oxygenator: an ex vivo study
Perfusion, January 1, 1998; 13(1): 53 - 57.
[Abstract] [PDF]


Home page
PerfusionHome page
O. F Jenkins, R. Morris, and J. M Simpson
Australasian perfusion incident survey
Perfusion, September 1, 1997; 12(5): 279 - 288.
[Abstract] [PDF]


Home page
PerfusionHome page
M. Kurusz
Lessons from perfusion surveys
Perfusion, July 1, 1997; 12(4): 221 - 227.
[PDF]


Home page
PerfusionHome page
P. D Beckley, P. D Shinko, and J. P Sites
A comparison of gaseous emboli release in five membrane oxygenators
Perfusion, March 1, 1997; 12(2): 133 - 141.
[Abstract] [PDF]


Home page
PerfusionHome page
S. Daniel
Review on the multifactorial aspects of bioincompatibility in CPB
Perfusion, May 1, 1996; 11(3): 246 - 255.
[Abstract] [PDF]


Home page
PerfusionHome page
N. Jones and C. Howell
Massive arterial air embolism during cardiopulmonary bypass: antegrade blood cardioplegia delivered by the pump an accident waiting to happen
Perfusion, March 1, 1996; 11(2): 157 - 161.
[Abstract] [PDF]


Home page
PerfusionHome page
M. Kurusz, B. D Butler, J. Katz, and V. R Conti
Air embolism during cardiopulmonary bypass
Perfusion, November 1, 1995; 10(6): 361 - 391.
[PDF]


Home page
Ann. Thorac. Surg.Home page
E. A. Tovar, C. D. Campo, A. Borsari, R. P. Webb, J. R. Dell, and P. B. Weinstein
Postoperative Management of Cerebral Air Embolism: Gas Physiology for Surgeons
Ann. Thorac. Surg., October 1, 1995; 60(4): 1138 - 1142.
[Abstract] [Full Text]


Home page
PerfusionHome page
A. Mehra, A. Akins, A. Maisuria, and B. Glenville
Air handling characteristics of five membrane oxygenators
Perfusion, January 1, 1994; 9(5): 357 - 362.
[Abstract] [PDF]


Home page
PerfusionHome page
B. Butler and M. Kurusz
Review article : Gaseous microemboli: a review
Perfusion, April 1, 1990; 5(2): 81 - 99.
[PDF]


Home page
VASC ENDOVASCULAR SURGHome page
A. Belboul, N. A. Khaja, P. Bergman, D. Roberts, and G. William-Olsson
Postoperative Morbidity Following Red Cell Deformability Changes During Cardiopulmonary Bypass Using Bubble and Membrane Oxygenators
Vascular and Endovascular Surgery, July 1, 1989; 23(4): 258 - 264.
[Abstract] [PDF]


Home page
PerfusionHome page
M. Kurusz and D. Wheeldon
Perfusion safety
Perfusion, April 1, 1988; 3(2): 97 - 112.
[PDF]


Home page
PerfusionHome page
T. Gourlay, M. Gibbons, and K. Taylor
Evaluation of a range of arterial line filters: Part II
Perfusion, January 1, 1988; 3(1): 29 - 35.
[PDF]


Home page
VASC ENDOVASCULAR SURGHome page
S.S. Kabbani, D.G. Ellertson, J.R. Crew, and E.S. Hanna
An Unusual Case of Systemic Embolism During Cardio-Pulmonary Bypass
Vascular and Endovascular Surgery, November 1, 1983; 17(6): 372 - 374.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1980 by The Society of Thoracic Surgeons.